- 10 -
3. Daily Maintenance
●
CLEAN THE FILTER
EVERY FOUR MONTHS.
1)
Undo the truss head screw. Remove the filter cover.
2)
Take out the filter and slap down the dust and dirt by hand.
If it is heavily contaminated, wash it by rubbing using
neutral detergent. Then, wash with water and dry it in the
shade.
3)
Please confirm whether there is any dust or dirt blocking the
inlets. If yes, please clear it up.
4)
Reassemble the filter back in place, and press in the filter
cover.Secure the filter cover with truss head screw.
○
Make sure that the filter cover packings are not dislocated
or broken before installation.
●
If the filter cover packings are broken, replace them in time,
or it could be the cause of leaking rain water in or
abnormal noise.
●
DAILY CHECKS
○
Is air blowing out properly?
○
Isn't the air pump making abnormal noise or vibrations?
○
Is the temperature of the air pump not abnormally high?
○
Is the power cord or plug not damaged, swelled or discolored?
※
If any irregularity is found, read
“REPAIR AND ITS ORDER”.
○
Prior to maintenance servicing, pull off the power cord to
stop operation of the air pump.
○
Since dust could enter the air pump and cause accidents
such as leakage or short circuit, be sure to do cleaning
regularly.
○
Keeping running over four months without cleaning-up could cause block of the
filter or inlet, which will lead to air circulation problem. Low discharged air
volume could decrease the life of diaphragms of valves, and worsen the water
quality in purification tank.