SBC-C90
SBC-C90 User Manual - Rev. First Edition: 1.0 - Last Edition: 1.0 - Author: A.R. - Reviewed by C.M. Copyright © 2021 SECO S.p.A.
53
4.3.17.5
Watchdog Configuration submenu
4.3.17.6
GPIO Configurations submenu
4.3.18
HSUART Transceiver Configuration submenu
Default FAN Duty Cycle (%).
Speed Change Duration
0 .. 50
Duration in seconds of linear FAN Speed Change.
Menu Item
Options
Description
Watchdog
Disabled / Enabled
Enables or disables the Watchdog Timer mechanism. When enabled, the following parameters will appear.
Event action
Raise WDT Signals
Power Button Pulse
Select the Watchdog action when Event time-out expires
Reset action
System Reset
Power Button Override
Raise WDT Signal
Select the Watchdog action when Reset time-out expires
Watchdog delay
[0..60]
Minutes before watchdog normal operations starts. During delay time-out, a refresh operation will
immediately trigger normal operation. Valid range is from 0 to 60.
Event time-out
[0..60]
Minutes without refresh before triggering selected event action. Refresh will restart the time-out. Valid range
is from 0 to 60
Reset time-out
[1..60]
Minutes without refresh before triggering selected reset action, this timer will start when event time-out is
expired. Refresh will restart the time-out. Valid range is from 1 to 60
Menu Item
Options
Description
GPIOx
Input
Output Low
Output High
Output Last
Configure GPIOx pin as input or output with a fixed starting value. Last means no changes with respect to
the last boot.
Menu Item
Options
Description
HSUART #0
HSUART #1
RS-232
RS-422
RS-485
Select among RS-232 (default), RS-422 or RS-485 interface for HSUART port 0 and 1.
Rx Termination
Disabled / Enabled
Option available when selecting RS-422 or RS-485 mode.