SECO-LARM Electric Door Strike with Vertical Adjustment
6
SECO-LARM U.S.A., Inc.
1.
Use the included electrical connector
marked 24VDC and connect its
white/black wires to the positive and
negative terminals of the control
device.
1.
Use the included electrical connector
marked 12VDC and connect its
red/black wires to the positive and
negative terminals of the control device.
For 24VDC Operation*:
For 12VDC Operation*:
12VD
C
12V
24VD
C
24V
Black Wire
Red Wire
White Wire
*
Diagrams are for illustrative purposes only. Polarity of wires is not important.
Crimp connectors are provided to make wiring
connections easier and more reliable. To install
the connectors:
1.
Insert the wires into the connector
(see "12/24 VDC Wiring Diagram," page 6).
2.
Use a crimping tool or pliers to evenly press
down on the head of the connector.
12/24 VDC Wiring Diagram*:
FAIL-SECURE
FAIL-SAFE
SECO-LARM
®
FAIL-SECURE
FAIL-SAFE
SECO-LARM
®
Installing the Crimp Connectors:
Crimp
Connector
Factory default: Fail-safe
Selecting Fail-Secure or Fail-Safe:
1.
Remove the locking screw and loosen the sliding screw.
2.
Slide the sliding screw to the desired setting. Replace the locking screw and retighten both
screws.
Fail Safe:
Fail Secure:
Locking
screw
Sliding
screw