Note: 

The mounting tabs are only used for 

aluminum and metal door frames. This is 

commonly done when retrofitting door frames. 

To mount the strike where the hollow door frame 
material is unsuitable for mounting, do the following:
1.

 

Punch or drill holes according to the template 
for installation of the mounting tabs, and the 
anchor nuts that reinforce them. 

2.

 

When installing, do not over-tighten the screws 
as small adjustments may be required to 
secure a snug fit for the door strike. 

Mounting the Trim Plate: 

Mounting the Strike Using Mounting Tabs: 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting Tabs 

Using the stick-on template as a guide: 
1.

 

Drill holes for mounting the strike, and cut a 
hole for the face-plate size being used. It is 
recommended to cut the hole slightly 
smaller than necessary.  

2.

 

Use a file to finish the shaping of the frame. 
This will improve the fit and finish of the 
installation. 

Preparing the Door Frame: 

Note: 

Trim plate is optional and may not be 

required in all installations. Only use the trim 

plate to cover any gaps in the door frame.  

1.

 

If the hole cut for the faceplate is too large 
or is jagged, the trim plate can be mounted 
over the hole to improve the appearance of 
the installation. 

2.

 

Screw the trim plate into the mounting holes 
at the top and bottom of the door strike 
using the included trim plate screws before 
installing the strike to the door frame. 

Machine 

Screws 

Содержание SD-996C-NUVQ

Страница 1: ...ic hardware mounted on the door 12 24 VDC Operation Vertical adjustable deadbolt opening sliding shim keeper and deadlatch ramp accommodates a wide range of lock types Accommodates deadbolts up to 1 F...

Страница 2: ...cycles UL Tested Level IV Destructive attack Level I Line security Level I Standby power Level I Latch throw 1 25mm max with 1 8 3mm door gap Dimensions 113 16 x15 8 x35 16 47x42x84 mm Note Not all p...

Страница 3: ...distance X from the side of the door frame and distance Y from the top of the door frame Use a pencil to mark the exact spot where the two lines intersect 2 Carefully peel off the short thin tab in t...

Страница 4: ...Tabs Mounting Tabs Using the stick on template as a guide 1 Drill holes for mounting the strike and cut a hole for the face plate size being used It is recommended to cut the hole slightly smaller th...

Страница 5: ...11D2Q faceplates with the mounting tabs shown in Mounting the Strike Using Mounting Tabs page 4 SD 996SS 11L1Q Note If it is necessary to cut a hole in the frame mounting tabs may be required to stre...

Страница 6: ...y Polarity of wires is not important Crimp connectors are provided to make wiring connections easier and more reliable To install the connectors 1 Insert the wires into the connector see 12 24 VDC Wir...

Страница 7: ...d adjust the deadbolt keeper up and down to align with the marked lines Adjusting Deadbolt Keeper 1 Move the door close to the strike and mark the deadlatch limit lines on the strike keeper when they...

Страница 8: ...and workmanship while used in normal service for three 3 years from the date of sale to the original customer SECO LARM s obligation is limited to the repair or replacement of any defective part if th...

Отзывы: