background image

   SECO-LARM

 

ELECTROMAGNETIC LOCK

 

 8 

                                                                    

SECO-LARM U.S.A., Inc.

 

   

 

 

 

 

 

 

 

 

Troubleshooting: 

LIFETIME LIMITED WARRANTY 

This SECO-LARM product is warranted against defects in material and workmanship 

while used in normal service for the lifetime of the product. SECO-LARM’s obligation is limited to the repair or replacement 
of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. Under no circumstances will SECO-

LARM be responsible for any costs or charges for removal, installation, or reinstallation. This Warranty is void if damage is 
caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or 

abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not 
operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-

LARM, and the purchaser’s exclusive remedy, shall be limited to repair or replacement only, at SECO-LARM’s option. In no 
event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of 

any kind to the purchaser or anyone else. This lifetime limited warranty is for products sold and installed in the United States 
and Canada. For all other countries the warranty is 1 (one) year. 

 

NOTICE:

 The information and specifications printed in this manual are current at the time of publication. However, the 

SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right 
to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. 
Copyright © 2010 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in 
whole or in part, without the written permission of SECO-LARM. 

 

SECO-LARM

 

 

U.S.A., Inc. 

16842 Millikan Avenue, Irvine, CA 92606  

 

Website: www.seco-larm.com

 

Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326   

E-mail: sales

@

seco-larm.com

 

 

mi-E941SA-300RQ.docx

 

Door does not lock                                         

  Check to make sure the wires are securely tightened to the terminal block.               

  Check that the power supply is connected and operating.                                 

  Use a multimeter to check the resistance of coils inside the lock. See below.                                

  Make sure the rubber washer is installed and free from damage.   

                           

 

Door locks, but can easily be forced open 

  Make sure the electromagnet and armature plate are properly aligned.       

  Make sure the contact surfaces of the electromagnet and armature 

  plate are clean and free from rust.  

 

                         

  Check the power leads with a multimeter to see if 12 or 24VDC is present.                                                                                                                                                         

  Use a multimeter to check the resistance of coils inside the lock. See below.                                

  Make sure the rubber washer is installed and free from damage.                 

  Check Voltage Selection Jumper for correct setting.               

 

 

 

 

  The electromagnet is fitted with a metal oxide varistor to prevent 

interference, so do not install a second diode. 

Delay in door releasing 

PITGW1

 

 

1.

 

Remove the faceplate from the lock. 

2.

 

Disconnect the wire harness from the circuit board.  

3.

 

Using a multimeter, measure the resistance across: 
Red/Green wires, and the Black/White wires.     

4.

 

Each coil should test at 

57

 ±10%.

     

5.

 

If one or both of coils shows an open, short, or incorrect 
resistance, replace the electromagnet.                       

White 

Black 

Green 

Red 

Wire Harness: 

57

 ±10%

 

57

 ±10%

 

If the Electromagnet has low or no holding force, check the resistance of the coils by 
performing the following steps: 

Содержание E-941SA-300RQ

Страница 1: ...cts 300 lb Single Door Electromagnetic Lock with Reversible Magnet E 941SA 300RQ Manual Reversible magnet for left or right swing doors Perfect for cabinets small enclosures or pedestrian gates Select...

Страница 2: ...rdware for typical installations L brackets Z brackets and U brackets are available for easy mounting Selectable 12 24 VDC Detachable faceplate Parts List 1 x Mounting plate 1 x Electromagnet 1 x Arma...

Страница 3: ...ounting screws NOTE When mounting the electromagnet it may be necessary to use a Z bracket 1 or 2 L brackets a U bracket and or plate spacers depending on the location and the type of door and frame U...

Страница 4: ...ditional SECO LARM accessories such as Z brackets L brackets U brackets and or spacer plates Please see the diagram on page 3 to decide if a particular application requires any mounting accessories Se...

Страница 5: ...htly Make sure the anti spin guide pins are in the two guide pin holes Mounting Plate Armature Plate 90 The rubber washer will be sandwiched between the two metal washers Armature screw Long self tapp...

Страница 6: ...Position a jumper over the two middle pins for 24VDC operation Position two jumpers on all four pins for 12VDC operation Voltage Selection Jumpers NOTE This should be the very last step as once the t...

Страница 7: ...ssories Also Available from SECO LARM Wired or Wireless RTE Plates NOTE Connect switching devices like push to exit switches between the power source and the positive terminal on the lock Connecting s...

Страница 8: ...M is also not responsible for misprints or typographical errors Copyright 2010 SECO LARM U S A Inc All rights reserved This material may not be reproduced or copied in whole or in part without the wri...

Отзывы: