Wire Length
25ft. 50ft. 75ft. 100ft. 150ft. 200ft. 250ft. 300ft. 400ft. 500ft. 1000ft.
Wire Gauge @ 420mA 20 18 18
18
16
14
14
12
10
10
--
Wire Length
25ft. 50ft. 75ft. 100ft. 150ft. 200ft. 250ft. 300ft. 400ft. 500ft. 1000ft.
Wire Gauge @ 210mA 24 24 22
20
18
18
16
16
14
14
14
24VDC Minimum Wire Gauge:
Wiring Diagram:
Maximum Distance from Power Source to Electromagnetic Lock:
12VDC Minimum Wire Gauge:
l
For a complete chart, please visit www.seco-larm.com
Optional
SECO-LARM
Electromagnetic Lock Accessories:
Also Available from
SECO-LARM:
Wired or Wireless RTE
Plates
*NOTE
: Connect switching devices like
push-to-exit switches between the
power source and the positive terminal
on the lock. Connecting switching
devices to the negative terminal may
cause a delay in unlocking.
Position a jumper over
the two middle pins for
24VDC operation
Position two jumpers
on all four pins for
12VDC operation
Voltage Selection Jumpers
“L” bracket
E-941S300R/LQ
“L” & “Z” brackets
E-941S300R/ZQ
“L” & “Z” & “U” brackets
E-941S300R/UQ