Secabo TC5 Smart Скачать руководство пользователя страница 5

Material

Temperature

Pressure

Time

Flock  film

170°C  -­  185°C

light-­medium

25s

Flex  film

160°C  -­  170°C

medium-­high

25s

Sublimation  flex

180°C  -­  195°C

medium-­high

10s  -­  35s

Sublimation  on

ceramic  mugs

200°C

medium-­high

150s  -­  180s

Sublimation  on  tiles

200°C

high

120s  -­  480s

(depending  on  thickness  of

material)

Sublimation  on

jigsaw  puzzles

200°C

light-­medium

25s

Sublimation

mousepads

200°C

medium

20s  -­  40s

Sublimation  on

textiles

200°C

medium-­high

30s  -­  50s

Sublimation  on

metal  plates

200°C

high

10s  -­  50s

(depending  on  thickness  of

material)

Important  note:  

You  should  carry  out  your  own  tests  with  the  transfer  material  and  backing  to  be

used  before  starting  production.  The  values  given  above  and  the  manufacturer’s  own  figures  are
only  intended  as  a  guide.  You  should  establish  the  washability  and  behaviour  during  transfer  in  your
own  tests.
The  recommended  values  do  not  imply  a  guarantee.  The  user  is  responsible  for  determining  and
using  the  appropriate  setting  for  his  particular  conditions.

Note  for  textile  work:  

After  pressing,  allow  textiles  to  cool  down  before  removing  any  type  of

backing  from  the  transfer  material.  The  hot  glue  in  the  transfer  material  develops  its  adhesive  force
only  in  the  cold  state.  If  the  adhesive  does  not  stick  in  the  cold  state,  it  may  have  been  pressed  too
cold  or  for  too  short  a  time.

Secabo  GmbH      Hochstatt  6-­8      85283  Wolnzach      Germany      [email protected]      www.secabo.com

Содержание TC5 Smart

Страница 1: ...make sure you read this manual carefully Reproduction of this manual requires written consent of Secabo GmbH Errors and amendments of technical details excepted all rights reserved Secabo GmbH is not...

Страница 2: ...ss for the first time Never reach into the heat press with your hands when it is connected to the power supply particularly when it is switched on and heated up danger of severe burns Never open the h...

Страница 3: ...e Connection for power supply and automatic fuse not shown f Base plate Controller With a large digital controller temperature C und F and pressing time can be adjusted The green digits are showing t...

Страница 4: ...ation causes less pressure counter clockwise rotation causes more pressure The settings cannot be changed during pressing Each time the pressing process is completed the counter display increments by...

Страница 5: ...er material and backing to be used before starting production The values given above and the manufacturer s own figures are only intended as a guide You should establish the washability and behaviour...

Страница 6: ...250g cm Pressure adjustment height adjustment of the base plate using the hand valve height adjustment of the base plate using the hand valve Power supply 230V 50Hz 60Hz 1 8kW 230V 50Hz 60Hz 2 0kW Am...

Страница 7: ...ungen der folgenden EG Richtlinien und Normen bereinstimmt EG Richtlinien EC Directives 2006 95 EG Niederspannungsrichtlinie 2006 95 EC Low Volatge Directive 98 37 EG Maschinenrichtlinie 2006 42 EG ab...

Отзывы: