10.2

  

Standalone Access Control Mode

10.3

 

Anti-passback Mode

11

 

Simple Troubleshooting

Under this mode:

The electric lock can be opened by reading user card or inputting user password on the 

device or external card reader.

Read anti-stress card or input anti-stress password on the device or external card reader to 

open the electric lock, the external alarm will sound at the same time.

The anti-passback means that it need read card not only enter room but also exit room to the 

same door, it cannot read card twice continuously to enter room or exit, prevent two people from 

entering and exiting with one card at the same time, under this mode:

Read anti-stress card or input anti-stress password on the device or external card reader to 

open the electric lock, the anti-passback mode will not affect the device, the external alarm will 

sound at the same time.

Read user card on the device or external card reader, user must read card on the device at 

the first time if want to enter room, user must read card on the card reader at the second time if 

want to exit room, the user must read card repeatly between the device and external card 

reader, then can enter room or exit room.

In anti-passback mode, user password is invalid.

Trouble Phenomenon

Reading distance too close

User password setting error

Cannot open door after 

inputting user password

Alarm under normal situation

No reaction after reading card

The Keypad light doesn’t work.

Can not enter administrator 
setting

Other Phenomenon

Fault Reason

1.Card quality issue

2.Switch power supply interferences 

card reading

1.The password setting does not 

comply with the specification

2.Setting user password under card 

reader mode

Use password 1234 to open door

When the product is installed, there is 

light leakage at the bottom

The product is not at the standby 

state

Keypad light mode setting incorrect

Forgetting administrator password

Not above reasons

Fault Reason&Solution

1.Please use original card

2.Power supply and standalone 

access control need connect to 

ground wire

1. User password can not set to 

1234

2. User password only can be 4-6 

digits
1234 is user password initial 

data, and can not use to open 

door, it must modify to other 

password number
When the device is installed, the 

bottom should be close to the 

wall without light leakage.
Press “*” to exit, the indicator 

become red, let the device 

standby state

1.Please set the key light mode 

to normal ON or automatic

2.In automatic mode, the 

indicator light will turn off 

automatically without operation 

after 30S

Reset to factory default, default 

administrator password 

is 888888.

Use conditions and parameters 

need to be reset without losing 

user data

Users can’t solve the problem by 

themselves, please consult our 

professional after-sales service 

staff

8/8

Содержание sKey2

Страница 1: ...sKey2 INSTRUCTION MANUAL...

Страница 2: ...s no large area non metal card reading window 125Khz built in EM HID card reader 13 56Mhz built in Mifare CPU card reader ISO14443A Multi function including card reader standalone access control anti...

Страница 3: ...ALARM 12V GND D0 D1 LED BZ PUSH 12V GND NO COM NC Stick the punch sticker on the wall drill 14mm hole for outlet and 4 6mm installation holes with expansion then insert 4 expansion rubber bungs into...

Страница 4: ...s new password Note password users must get their ID number and initial password from administrator for cardholders modifying password must use card mode at the first time 5 Alarm Function 6 Anti crac...

Страница 5: ...Red Flash Buzzer Short Beep Long Beep Long Beep Long Beep 3 short beep Two short beep Long beep Alarm Voice Red Flash 6 8 digits administrator password Remark Default 888888 Function Enter administra...

Страница 6: ...igit card number such as 0007765567 some cards omit the front number 000 written in 7765567 and add 0 in front to input 0007765567 Adding a user password 1234 with the card at the same time this passw...

Страница 7: ...rking state When the alarm is turned off it is invalid for the anti tamper anti stress and door status alarm Refers to static state operation in accordance with the normal instructions After entering...

Страница 8: ...Mifare card output format is wiegand 26 37 HID card does not need to be set and automatically wiegand 26 37 output according to card format The output format should match the connected controller and...

Страница 9: ...tting error Cannot open door after inputting user password Alarm under normal situation No reaction after reading card The Keypad light doesn t work Can not enter administrator setting Other Phenomeno...

Страница 10: ...sKey2 complete manual...

Отзывы: