4
.
User Operation
4.1 Use Card Open Door
Read valid user card once, the lock opened.
4.2 Use Card and Password Open Door
Read valid user card once, then enter 4-6 digits user’s password, press “#”, the lock opened.
4.3 Use Card or Password Open Door
Read user card once, the lock opened.
Or enter 4-6 digits user’s password, press “#”, the lock opened.
4.4 Multi-Card Open Door: the door opening mode is required to be card
mode, the number of multi-card door opening is set to 2-10
Read 2-10 times different valid user card(the interval should not exceed 5 seconds), the lock
opened.
4.5 Electric Lock Switch Mode
In normal mode, the electric lock will be closed for a period of time after being opened, which is
equal to a delay switch.
In switch mode, switch the state of electric lock once for each valid unlock operation, and keep
the state of lock all the time.
4.6 Modify User Password
Press “*”, read user card once, enter 4-6 digits old password #, enter 4-6 digits new password
#, repeat enter 4-6 digits new password#.
Or press “#”, enter 1-2000(ID) #, enter 4-6 digits old password #, enter 4-6 new password #,
repeat enter 4-6 digits new password #.
Note: password users must get their ID number and initial password from administrator, for
cardholders, modifying password must use card mode at the first time.
5. Alarm Function
6. Anti-crack Function
5.1 Anti-tamper Alarm
When turn on anti-tamper Alarm function, if the device is disassembled illegally, the built-in
buzzer and external alarm will both alarm.
5.2 Door Status Alarm
When connect with door status switch, if the door is opened illegally, the built-in buzzer and
external alarm will both alarm.
5.3 Anti-stress Alarm
When the door is forced to open by illegal elements:
Read anti-stress card, or enter anti-stress password #, the door opened, the external alarm will
alarm, but built-in buzzer don’t alarm.
5.4 Cancel the Alarm
During anti-tamper and door status alarm, read valid user card or enter administrator password
to cancel alarm, if there is no any operation, the alarm will canceled automatically beyond the
set alarm time.
To prevent malicious cracking of the card and password, try to enter an invalid administrator
password
、
user password
、
anti-stress password or read invalid card, and start corresponding
operation after 10 times errors, including three levels: unlimited number of errors, 10 times
errors locked for 10 minutes, 10 times errors alarm for 1-3 minutes.
3/8
Содержание sKey2
Страница 1: ...sKey2 INSTRUCTION MANUAL...
Страница 10: ...sKey2 complete manual...