Way to enter menu : * (Hold down for more than 2 seconds), (Admin password) #

 

Menu 

Parameter or operation step 

Function   

Default value 

03 

0# 

Reader mode 

1# 

Single-door mode 

2# 

Double-doors mode   

3# 

Interlock mode 

9# 

Demo mode 

04 

0# 

Cannot read card 

1# 

Only read EM card 

2# 

Only read HID card 

3# 

Only read IC card 

4# 

Read EM and HID card 

5# 

Read EM and IC card   

6# 

Read HID+IC card 

7# 

Read EM, HID and IC card 

09 

0000# 

Restore default settings, admin password 

and user information unchanged 

 

40 

0, # 

Set Alarm time to 0, means no alarm 

(1-99)# 

Set the alarm time to 1-99 minutes 

41 

0# 

Disable Anti-dismantle alarm 

1# 

Enable Anti-dismantle alarm 

42 

0# 

Alarm lead output alarm signal voltage 

1# 

Alarm lead output doorbell signal voltage 

50 

0# 

Indicator light is always off 

1# 

Red indicator light is always on 

2# 

Green indicator light is always on(reader 

mode) 

51 

1,1,…,# 

Decrease the brightness of the normally 

bright red indicator 

18 

2,2,…,# 

Increase the brightness of the normally 

bright red indicator 

52 

0# 

Key backlit is always off 

1# 

Key backlit is always on 

(2-99)# 

After delay 2-99 seconds, Key backlit turn to 

micro light 

53 

1,1,…,# 

Decrease the brightness of the backlit   

14 

2,2,…,# 

Increase the brightness of the backlit 

54 

0# 

Disable the buzzer   

1# 

Enable the buzzer   

55 

1,1,…,# 

Decrease the keypad tone   

10 

2,2,…,# 

Increase the keypad tone   

56 

0# 

The # key can’t be used as doorbell key 

1# 

The # key can be used as doorbell key 

Содержание B6 Plus

Страница 1: ...B6K2 Standalone Access Controller User Manual V1 0 NetDigital Security http www netdigital com au 1 B6 Plus USER MANUAL V1 0...

Страница 2: ...pen door 15 4 Basic Functions 15 4 1 Management menu operations 15 4 1 1 Change Admin Password 15 4 1 2 Set or delete Super open password 16 4 1 3 Set admin card 16 4 1 4 Delete admin card 16 4 1 5 Se...

Страница 3: ...tion 25 4 3 1 Get user card or PIN 25 4 3 2 Change user PIN 25 4 3 3 User Open door 25 4 4 Other operations 26 4 4 1 Cancel alarming 26 4 4 2 Admin Password initialization 26 4 4 3 Restore factory set...

Страница 4: ...ic reader mode that customer can set output format Support Card and PIN Multi cards to open the door Support Super open card and Super open password to open door Support Add card Delete card Anti dure...

Страница 5: ...el Card type Keypad Lead wire Single door Standalone Access Controller B6K EH Plus EM HID Own 12 B6K IC Plus IC CPU Own 12 Double doors Standalone Access Controller B6K2 EH Plus EM HID Own 16 B6K2 IC...

Страница 6: ...The product wiring colors and functions are shown in the following table Color Symbol Functions Light green AC2 One port of the AC power supply Blue NO Normal open port of Relay Purple COM Common port...

Страница 7: ...B6K2 Standalone Access Controller User Manual V1 0 NetDigital Security http www netdigital com au 7...

Страница 8: ...B6K2 Standalone Access Controller User Manual V1 0 NetDigital Security http www netdigital com au 8...

Страница 9: ...B6K2 Standalone Access Controller User Manual V1 0 NetDigital Security http www netdigital com au 9...

Страница 10: ...B6K2 Standalone Access Controller User Manual V1 0 NetDigital Security http www netdigital com au 10...

Страница 11: ...B6K2 Standalone Access Controller User Manual V1 0 NetDigital Security http www netdigital com au 11...

Страница 12: ...B6K2 Standalone Access Controller User Manual V1 0 NetDigital Security http www netdigital com au 12...

Страница 13: ...ameter when you type this key it means input is finished means cancel current operation or back to previous menu Management menu fix to 2 digits from 00 99 Don t press on the menu behind after into me...

Страница 14: ...e if user does not sure of the mode please set it again the steps please follow 03 1 3 4 Set door opening time to 2S The factory default door opening time is 2S so if user request factory default time...

Страница 15: ...er cannot continue other operation If the Admin Password is correct the indicator light will turn to green once and then back to red flash status Other operations must be performed in this status If t...

Страница 16: ...card Set 1 3 Anti duress cards 01 5 read card read card Set 1 3 Authorization cards 01 6 read card read card Set 1 3 Normal open cards Note Each type of admin card can be divided several times to set...

Страница 17: ...user card information are not deleted and the specific default values are shown in the appendix 4 1 8 Add User 4 1 8 1 Automatically generates ID numbers to add user card Read card continuously to ad...

Страница 18: ...t card will be based on ID number and card number each time add one card ID number and card number will add 1 at the same time till to all card is added In order to prevent duplication of card numbers...

Страница 19: ...ant chapter of admin cards operation 4 1 13 Set Limits User Mode 33 0 disable users to use 33 1 default value enable users to use Notes A better way to implement the limits of user mode is operation b...

Страница 20: ...4 1 10 default value is 10 set maximum times for the error operation from 1 to 10 45 1 99 default value is 10 set time locked after the error operation indicate maximum times from1 to 99minutes Note A...

Страница 21: ...e buzzer only concern normal users operation such as the sound of opening door by PINs or read cards When you press the key for 2 seconds the buzzer is forced to enable such as entering the management...

Страница 22: ...232 TTL HEX format 61 2 D0 output RS232 TTL ASCII 8 format 61 3 D0 output RS232 TTL ASCII 10 format Note The wiegand format is an international protocol for access control products But the width of pu...

Страница 23: ...6 0110 7 0111 8 1000 9 1001 1010 0 0000 1011 Single key output 6 bits wiegand data with parity bit E very key output a 6 bit data Corresponding relation is 1 000010 2 000100 3 000111 4 101001 5 101010...

Страница 24: ...xiting add user card state 4 2 3 Delete card operation Read Delete card read user card read user card read Delete card Note Delete card is mainly used for rapid continuously to delete the user card fi...

Страница 25: ...e user card The user card and the user PIN are divided into first zones and second zones they operate the door of the corresponding zone respectively The number of user PIN is specified zone 1 is 4 6...

Страница 26: ...the initial password by special operation Operation as follows Power off press the keys do not move and power on Release the key after two beep Admin password has restored to 888888 But the other par...

Страница 27: ...s the same with the zone 1 With 7 digit Admin Password into management mode only menus 00 01 02 10 12 21 22 30 36 are valid 4 5 4 Operation characteristics in Interlock mode Interlock mode is refers t...

Страница 28: ...1 99 minutes 41 0 Disable Anti dismantle alarm 0 1 Enable Anti dismantle alarm 42 0 Alarm lead output alarm signal voltage 0 1 Alarm lead output doorbell signal voltage 50 0 Indicator light is always...

Страница 29: ...4 bits wiegand data no check bit 0 1 Single key output 6 bits wiegand data with parity bit 2 Single key output 8bits wiegand data with complement check bit 3 4 digit key buffered output 4 1 5 digit k...

Страница 30: ...mat card number to add users 10 10 digit format card number 10 10 digit format card number Input 10 digit format card number to add users 11 ID read card ID read card Specify ID number and read card t...

Страница 31: ...e closing prompt tone for 0 99 seconds 10 40 0 Set the alarm time to 0 means no alarm 0 1 99 Set the alarm time to 1 99 minutes 41 0 Disable anti dismantle alarm function 0 1 Enable anti dismantle ala...

Страница 32: ...more than 2 seconds Admin password mainly used to operation second zone related content as shown in the following table Way to enter menu Hold down for more than 2 seconds 2 Admin password Menu Parame...

Страница 33: ...D 10 10 digit format card number card quantity Add 10 digit format serial number card users 21 Read card read card Delete card user by reading card 8 8 digit format number 8 8 digit format number Spec...

Страница 34: ...ightness of the backlit 14 2 2 Increase the brightness of the backlit 55 1 1 Decrease the keypad tone 10 2 2 Increase the keypad tone 6 Precautions in use Lead line cannot be connected wrong especiall...

Страница 35: ...rd Change by Setting card or press the key to initialize Can enter management mode but part of the menu is invalid 1 can t setting some menu in default password only can change admin password Change A...

Отзывы: