Страница 1: ...ommand impulse is received before the activation of the limit switch the direction of movement of the mechanism will be reversed whether engaged in opening or closing operations Step by step Using either the radio control CODE led lit or the low tension button panel PUL to operate the gates commands will have the following effect the first command impulse activates the opening mechanism either for...

Страница 2: ... key selects the type of function to be stored selection is indicated by a flashing LED By pressing the key repeatedly you can select the desired function The selection remains active for 10 seconds indicated by the flashing LED after 10 seconds the control unit returns to its original status SET key programmes the information according to the type of function selected previously using the SEL key...

Страница 3: ... key to the RIT ANTE LED when flashing press the SET key wait for the desired interval of time then press the SET key again the fixed door delay time of 2 seconds during opening is stored the door delay time during closing is stored for the programmed time and the RIT ANTE LED is on To restore the initial configuration without door delay go to the RIT ANTE LED when flashing then press the SET key ...

Страница 4: ...f the transmission code not enabled to enable the function proceed as follows check the extended menu 2 is enabled the T PAUSA and RIT ANTE LEDs flash simultaneously press the SEL button until the TIPO MOTOR LED flashes then press the SET key at the same time the LED TIPO MOTOR turns on and remains steady and programming is complete Repeat the operation to restore the previous configuration B AUTO...

Страница 5: ... the TIPO MOTORE AUTO PGM and CODE LEDs are steady while the CODE PED Led flashes press SET to confirm The default setting is Level 3 RESET To restore the default configuration press the SEL and SET keys simultaneously all RED LEDs will light up and then switch off DIAGNOSTICS Photocell test The control unit can be fitted with safety devices in accordance with step 5 1 1 6 of the EN 12453 standard...

Страница 6: ...back of the casing is set up for mounting on a wall holes for mounting with nogs or holes for screws Take all precautions to ensure the IP degree of protection is not affected during installation If applicable the keypad for manual control must be mounted in such a way as not to compromise the safety of the user The motor reducer used to move the shutter must comply with section 5 2 7 of EN 12453 ...