for 5 seconds; the T. MOT. and WIND SPEED LEDs will flash 
alternately and the user has 30 seconds within which to select 
the functions of extended menu 2 using the SEL and SET but-
tons. When this time has elapsed the control unit returns to the 
main menu.

---------------------- EXTENDED MENU  2    -----------------

Reference LED                LED Off                              LED On

A) CODE               Auto movements = OFF      Auto movements = ON 
B) SENS. CODE   Anemometer Test = OFF         Anemometer Test = 
ON                   
C) T. MOT.                                Flashing beacon ON/OFF             
D) WIND SPEED                      Flashing beacon ON/OFF             

A) CODE (Automatic Movement Lock):

The  control  unit  enables  the  prevention  of  automatic  move-
ments  (Up  /  Down  sun  blind  movements  on  the  Wind  sensor 
command or Automatic sensors function), so that if a Stop com-
mand is sent from a radio control during movement, the control 
unit  momentarily  locks  the  automatic  movements  until  a  new 
Up or Down command is sent.. The control unit is supplied by 
the manufacturer with the Automatic Movement Lock disabled; 
to enable the function proceed as follows: check that the exten-
ded menu is enabled (T. MOT. and WIND SPEED LEDs start 
flashing simultaneously), use the SEL button to navigate to the 
CODE  LED  when  flashing  and  press  the  SET  button:  the 
CODE LED remains lit in a constant manner and programming 
is complete. Repeat the procedure to restore the previous con-
figuration.

B) SENS. CODE (Wired Anemometer Test):

The control unit can be used to check the operation of the con-
nected Wind sensor, and to make sure the rotation direction is 
correct. When installing the device, we recommend the blind is 
placed in an intermediate position so that you can see all con-
firmation movements  during  the test  procedures.  After making 
sure the Wind sensor is operating correctly, you must remem-
ber to disable the Test.

Anemometer Test:

 manually rotate the Anemometer blades; at 

the same time, the control unit will cause an upward movement 
lasting 5 seconds.

Programming:

 The control unit is supplied by the manufacturer 

with the Wired Wind sensor test disabled. To enable the Test, 
proceed as follows: check that extended menu 2 is enabled (T. 
MOT.  and  WIND  SPEED  LEDs  start  flashing  simultaneously), 
use the SEL button to navigate to the SENS. CODE LED when 
flashing and press the SET button: the SENS. CODE LED re-
mains  lit  in  a  constant  manner  and  programming  is  complete. 
Repeat the procedure to restore the previous configuration.

Important:

  for  information  on  the  Wireless  Wind  sensor  test, 

please refer to the Wireless Wind sensor manual.

R

ESET

To reset the default configuration of the control unit, press the 
SEL  and  SET  buttons  simultaneously;  all  indicator

 

LEDs  will 

switch on and then off again immediately.

4

Rev. 1.1      03/12/10

Содержание LR 2215 Series

Страница 1: ...trols upward movement until the motor running time has elapsed and T4 controls downward movement If a command is sent in the same direction before the motor running time has elapsed the control unit will ignore the command if a com mand is sent in the opposite direction before the motor running time has elapsed the control unit will invert the direction of the motor OPERATION USING DIFFERENT MODEL...

Страница 2: ...and Dip 2 ON The User present operating mode can be obtained using the radio control and the keypad i e control must be constantly en abled so that the blind or shutter can be moved as necessary The movement stops when the control is released 4 Venetian blind operation Dip 1 and 2 ON Venetian blind operation can be obtained using the radio con trol and the keypad this involves 2 seconds of User Pr...

Страница 3: ...le flash the same number of times as the stored Wind Safety threshold each WIND SPEED LED double flash corresponds to an increase of 5 km h for ex ample 5 WIND SPEED LED flashes 25 km h Wind Safety threshold selection from 5 to 40 km h The sensor is supplied with a default Wind Safety threshold set ting of 25 km h WIND SPEED LED OFF The Wind Safety threshold may be programmed in the following way ...

Страница 4: ...complete Repeat the procedure to restore the previous con figuration B SENS CODE Wired Anemometer Test The control unit can be used to check the operation of the con nected Wind sensor and to make sure the rotation direction is correct When installing the device we recommend the blind is placed in an intermediate position so that you can see all con firmation movements during the test procedures A...

Страница 5: ... provisions set out by current legislation Compliance with these obligations and the implementation of the minimum safety requirements is the responsibility of the installer We recommend installation is performed in full compliance with EN 60335 2 97 Household electrical appliances and similar Safety part 2 Particular requirements for drives for rolling shutters awnings blinds and similar equipmen...

Отзывы: