Seav LR 2215 Series Скачать руководство пользователя страница 3

If the maximum number of radio controls has been reached and 
a  programming  process  started,  the  control  unit  will  indicate 
that  it  has  failed  by  flashing  all  the  LEDs  except  the  CODE 
LED,  which  will  remain  lit  in  a  constant  manner. After  10  se-
conds the control unit exits programming mode.

2)

SENS. CODE  

(Wireless Sensor programming)

Wireless Wind sensor programming:

To  programme  the  Wireless  Wind  Sensor  transmission  code, 
proceed as follows: Use the SEL button to navigate to a posi-
tion  where  the  SENS.  CODE  LED  flashes;  at  the  same  time, 
send  the  Wireless  Wind  sensor  code  using  the  special  button 
inside  the  sensor.  The  SENS.  CODE  LED  will  remain  lit  in  a 
fixed manner and programming will be complete. If the Wireless 
Wind sensor code is not sent within 2 minutes, the control unit 
exits programming mode. 

Deleting the codes:

To  delete  the  Wireless  Wind  sensor  codes  stored  in  the 
memory, proceed as follows: press the SEL button; the SENS. 
CODE LED will start to flash. Then press the SET button; the 
SENS.  CODE  LED  will  switch  off  and  the  procedure  is  com-
plete.

Wireless Wind sensor already stored warning:

If the user attempts to perform the programming procedure for 
a Wireless Wind sensor which is already stored in the memory, 
the SENS. CODE LED will begin to flash rapidly for a few mo-
ments, to indicate that this procedure cannot be performed; the 
unit then returns to the programming stage once again.

Maximum number of Wireless Wind sensors which can be  
stored:

If  the  maximum  number  of  Wireless  Wind  sensors  has  been 
reached  and  a  programming  process  started,  the  control  unit 
will indicate that it has failed by flashing all the LEDs except the 
SENS. CODE LED, which will remain lit in a constant manner. 
After 10 seconds the control unit exits programming mode.

Warning indicator:

If there is no communication between the Wireless Wind sensor 
and the control unit, after 20 minutes the safety upward move-
ment will be activated automatically. If this lack of communica-
tion persists, further commands will still, nevertheless, result in 
the control unit being set to safety mode.

3)

T. MOT. 

(Max. Motor Timer programming time 4 minutes) 

The control unit comes with a motor power supply time of two 
minutes (T. MOT. LED OFF).
The motor running time must be programmed when the shutter 
is down, in the following manner:
Press the SEL button until the T. MOT LED flashes, then press 
and  hold  the  SET  button;  the  shutter  will  begin  to  move  up-
wards.  Once  the  desired  position  has  been  reached,  release 
the SET button – at this very moment, the motor running time 
will be stored and the T. MOT LED will remain lit.
If  you  are  using  an  automation  which  has  a  stop  limit,  we  re-
commend  that  you  set  a  time  which  exceeds  the  stop  limit  of 
the shutter by a few seconds.
If you want unlimited motor running time, perform the same pro-
gramming  procedure,  holding  down  the  SET  button  for  less 
than two seconds; the T. MOT LED will remain lit and the un-
limited  time  function  will  be  set.  The  procedure  may  be  re-
peated if a mistake is made during programming.

4)

WIND SPEED 

(Wind Safety threshold programming)

Displaying the programmed Wind threshold:

The  Wind  Safety  threshold  may  be  displayed  in  the  following 
way: use the SEL button to navigate to the WIND SPEED LED 
position; the LED will double-flash the same number of times as 
the  stored  Wind  Safety  threshold  (each  WIND  SPEED  LED 
double-flash  corresponds  to  an  increase  of  5  km/h),  (

for  ex­

ample: 5 WIND SPEED LED flashes = 25 km/h).

Wind Safety threshold selection from 5 to 40 km/h

The sensor is supplied with a default Wind Safety threshold set-
ting of 25 km/h (WIND SPEED LED OFF).
The Wind Safety threshold may be programmed in the following 
way: use the SEL button to navigate to the WIND SPEED LED, 
then press the SET button to start the programming procedure: 
the WIND SPEED LED will double-flash at the same time (each 
WIND SPEED LED double-flash corresponds to an increase of 
5 km/h). Press the SET button when the desired threshold has 
been reached; at that moment the selected value will be stored 
in  the  memory  and  the  WIND  SPEED  LED  will  remain  lit  (

for 

example: 5 WIND LED double­flashes = 25 km/h).

The  procedure  may  be  repeated  if  a  mistake  is  made  during 
programming.

EXTENDED MENU  1

The control unit is supplied by the manufacturer with the option 
of selecting only the functions listed in the main menu.
To  enable  the  functions  of  extended  menu  1,  proceed  as  fol-
lows:  press  and  hold  the  SET  button  for  5  seconds;  the  T. 
MOT.  and  WIND  SPEED  LEDs  will  start  flashing  alternately. 
The user then has 30 seconds in which to select the extended 
menu  functions  using  the  SEL  and  SET  buttons.  After  30 
seconds the control unit returns to the main menu.

---------------------- EXTENDED MENU  1    -----------------

Reference LED                LED Off                              LED On

A) CODE              remote PGM = OFF                       remote PGM = 
ON
B) SENS. CODE   Safety upward mov. =OFF     Safety upward mov. 
=ON
C) T. MOT.                                Flashing beacon ON/OFF             
D) WIND SPEED                      Flashing beacon ON/OFF             

A) CODE 
(Remote programming of radio control):

The  control  unit  allows  the  transmission  code  to  be  pro-
grammed remotely, without using the SEL button on the unit it-
self.
To  programme  a  transmission  code  remotely,  proceed  as  fol-
lows: send the radio control code continuously for more than 10 
seconds;  the  control  unit  will  enter  the  programming  mode  as 
described above for the CODE LED in the main menu.
The  control  unit  is  supplied  by  the  manufacturer  with  remote 
programming of a transmission code not enabled; to enable the 
function  proceed  as  follows:  check  that  the  extended  menu  is 
enabled (T. MOT. and WIND SPEED LEDs start flashing altern-
ately), use the SEL button to navigate to the CODE LED when 
flashing and press the SET button: the CODE LED remains lit 
in  a  constant  manner  and  programming  is  complete.  Repeat 
the procedure to restore the previous configuration.

B) SENS. CODE (Safety upward movement):

The control unit is supplied by the manufacturer with the Safety 
upward movement function disabled; if you wish to enable the 
function,  so  that  after  12  hours  of  Wind  sensor  inactivity  the 
control unit automatically sends a command for Safety upward 
movement, proceed as follows: check that the extended menu 
is enabled (T. MOT. and WIND SPEED LEDs start flashing al-
ternately), use the SEL button to navigate to the SENS. CODE 
LED  when  flashing  and  press  the  SET  button:  the  SENS. 
CODE LED remains lit in a constant manner and programming 
is complete. Repeat the procedure to restore the previous con-
figuration.

EXTENDED MENU  2

The  control  unit  is  supplied  by  the  manufacturer  with  the  only 
option  of  selecting  the  functions  listed  in  the  main  menu  dir-
ectly.
To  enable  the  functions  in  extended  menu  2,  proceed  as  fol-
lows:  access  extended  menu  1  (as  described  in  the  corres-
ponding paragraph), then press the SET button again and hold 

3

Rev. 1.1      03/12/10

Содержание LR 2215 Series

Страница 1: ...trols upward movement until the motor running time has elapsed and T4 controls downward movement If a command is sent in the same direction before the motor running time has elapsed the control unit will ignore the command if a com mand is sent in the opposite direction before the motor running time has elapsed the control unit will invert the direction of the motor OPERATION USING DIFFERENT MODEL...

Страница 2: ...and Dip 2 ON The User present operating mode can be obtained using the radio control and the keypad i e control must be constantly en abled so that the blind or shutter can be moved as necessary The movement stops when the control is released 4 Venetian blind operation Dip 1 and 2 ON Venetian blind operation can be obtained using the radio con trol and the keypad this involves 2 seconds of User Pr...

Страница 3: ...le flash the same number of times as the stored Wind Safety threshold each WIND SPEED LED double flash corresponds to an increase of 5 km h for ex ample 5 WIND SPEED LED flashes 25 km h Wind Safety threshold selection from 5 to 40 km h The sensor is supplied with a default Wind Safety threshold set ting of 25 km h WIND SPEED LED OFF The Wind Safety threshold may be programmed in the following way ...

Страница 4: ...complete Repeat the procedure to restore the previous con figuration B SENS CODE Wired Anemometer Test The control unit can be used to check the operation of the con nected Wind sensor and to make sure the rotation direction is correct When installing the device we recommend the blind is placed in an intermediate position so that you can see all con firmation movements during the test procedures A...

Страница 5: ... provisions set out by current legislation Compliance with these obligations and the implementation of the minimum safety requirements is the responsibility of the installer We recommend installation is performed in full compliance with EN 60335 2 97 Household electrical appliances and similar Safety part 2 Particular requirements for drives for rolling shutters awnings blinds and similar equipmen...

Отзывы: