Fault Diagnostics
VIB. Troubleshooting
Dishwasher troubleshooting
Two NTC’s protect the heater. Both NTC’s are checked by the control – if they
overheat, the control shuts down the dishwasher (
E:08
error code). The
dishwasher shuts down if only one NTC returns a signal (
E:12
error code) or if
they show different values (
E:11
error code).
Heat pump terminal measurements
There are two connectors, 7-pin and 3-pin.
7-pin connector (heater / NTC’s / pump ground)
The 7-pin connector connects to the heat pump heater, NTC’s and
ground.
3-pin connector (3-pole BLDC motor)
The 3-pin connector connects to the 3-pole BLDC motor. The power
control module controls motor speed, starting and stopping.
Drain pump
There is a single 3-pin connector, connecting to the 3-pole BLDC pump motor.
Resistances as follows:
1 – 2:
89.6
Ω
(@ 68 ºF)
2 – 3:
89.6
Ω
(@ 68 ºF)
3 – 1:
89.6
Ω
(@ 68 ºF)
702_58300000150187_ara_en_a
7
Pump
Motor
6 5
4
3
2
1
7 –
NTC 1
6 –
NTC common
5 –
NTC 2
4 –
Line (hot)
3 –
X1 (heater common)
2 –
Neutral
1 –
Ground