background image

2

CONTENTS

INTRODUCTION/WARRANTY. . . . . . . . . . . . . . . . . . . . . 2

SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5

SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6

PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

INTRODUCTION

Please read our instructions before you install and use your
new pump; this will help you obtain full value and good ser-
vice from it. It will also help you avoid needless service costs
that result from causes we cannot control and cannot cover
in our warranty.

Carefully read and follow all safety instructions in this
manual or on pump.

This is a safety alert symbol.

When you see this symbol on your pump or in this manual,
look for one of the following signal words and be alert to the
potential for personal injury.

warns about hazards that 

will 

cause serious

personal injury, death or major property damage if ignored.

warns about hazards that 

can 

cause serious

personal injury, death or major property damage if ignored.

warns about hazards that 

will 

or 

can 

cause

minor personal injury or property damage if ignored.

The word 

NOTICE 

indicates special instructions which are

important but not related to hazards.

1. Read these rules and instructions carefully. Failure to fol-

low them could lead to serious bodily injury and/or prop-
erty damage.

2. Check your local codes before installing. You must com-

ply with their rules.

3. Vent sewage or septic tank according to local codes.

4. Do not install pump in any location classified as haz-

ardous by National Electrical Code, ANSI/NFPA 70-1984.

Hazardous voltage. Can shock, burn

or cause death.

During operation the pump is in water.

To avoid fatal shocks, proceed as follows if pump needs
servicing:

5A. Disconnect power to outlet box before pulling pump

cord plug.

5B. Take extreme care when changing fuses. Do not stand

in water or put your finger in fuse socket.

5C. Do not modify cord and plug unless removing plug com-

pletely and wiring pump directly into switch box or con-
troller. When using cord and plug, plug into a grounded
outlet only. When wiring to a system control, connect
pump ground lead to system ground.

6.

Do not run pump dry. Dry running can overheat pump,
(causing burns to anyone handling it) and will void warranty.

7. Pump normally runs hot. To avoid burns when servicing

pump, allow it to cool for 20 minutes after shutdown be-
fore handling it.

8. In normal service, motor should not need oiling. 

DO

NOT 

attempt to oil pump motor. A special oil has been

put into the motor housing at the factory; use of any
other oil will void warranty and could damage the pump.

NOTICE:

This unit is not designed for applications involving

salt water or brine! Use with salt water or brine will void
warranty.

LIMITED LIFETIME WARRANTY on CRAFTSMAN

®

PROFESSIONAL 

1/2-HP SUBMERSIBLE SEWAGE PUMP 

Provided that it is installed and operated according to the instructions in the owner’s manual, if this pump ever fails for the origi-
nal purchaser due to a defect in material or workmanship, return it to your nearest Sears store, and Sears will replace it free of
charge. You pay for labor if you choose to have Sears install the replacement pump.

Warranty service is available by calling Sears at 1-800-4-MY-HOME

®

.

LIABILITY LIMITATION

Sears is not liable for loss or damage to property, nor for any incidental or consequential loss or expense from property damage,
that results directly or indirectly from the use of this product. Some states do not allow the exclusion or limitation of property,
incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This warranty applies only while this product is used in the United States.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, IL 60179

GENERAL SAFETY INFORMATION

Содержание Craftsman 390.304051

Страница 1: ...ng Instructions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Installation Electrical Service Repair Pa...

Страница 2: ...emoving plug com pletely and wiring pump directly into switch box or con troller When using cord and plug plug into a grounded outlet only When wiring to a system control connect pump ground lead to s...

Страница 3: ...tighten only The rate of flow in the discharge pipe must keep any solids present in suspension in the fluid To meet minimum flow requirements 2 feet per second in discharge line size pipe as follows A...

Страница 4: ...voids the warranty and could ruin the pump ELECTRICAL CONNECTIONS Risk of electric shock When servicing pump always disconnect power to electrical outlet and remove pump electric cord from outlet The...

Страница 5: ...s disconnect power to electrical outlet and remove pump electric cord from outlet 1 If pump does not operate a Check for loose plug at electric outlet b Check for blown fuses or tripped circuit breake...

Страница 6: ...works Switch Replacement Figure 7 NOTICE Float must be able to swing through its complete arc without interference from sidewall of sump plumbing or any other object 1 Unplug cord from power source 2...

Страница 7: ...ower Volute 3 PW5 15P Impeller 4 U30 912PS Screw 4 required 5 PW1 10P Upper Volute 6 PS117 54 TSE Power Cord Assembly 7 U30 955PS 8 x 5 8 Type A Screw 8 CC0030 13 Clamp 9 PS117 144P Float Switch Repai...

Страница 8: ...xisting Agreement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES America...