EX100/200 SERIES INSTRUCTIONS

Seametrics • 253.872.0284 

Page 11 seametrics.com

Grounding Guidelines:

For best results, use a good quality earth ground, such as 

metallic water piping or a driven ground, to ensure a good 

connection to earth ground and good noise suppression.

If the flow sensor is installed in metallic piping, for optimum 

connection clamp wire to the piping a short distance to one 

side of the flow sensor using an electrical grounding clamp. 

Connect the wire to the earth ground and to one of the 

housing screws.

For Non-Metallic Pipe: 

Connect one to the housing 

screws by wire to a good earth ground, such as metalic 

water piping or a rod driven into the ground.

EX meters are usually unaffected by moderate levels of 

electrical noise.  In some applications performance may be 

improved by taking the following steps:

•   Use shielded twisted pair cable (Belden 8723 or  

   

equivalent above ground or Alpha 35482 or equivalent 

burial).

•   Clamp a ferrite bead (Steward 28A2029-OAO or  

 

equivalent) on meter signal/power wire within 3/4”  

of the meter strain relief (tape or tie wrap in place if     

necessary).  See diagram below.

•   IMPORTANT - Connect the cable shield ground  

  

wire to ground, ONLY at power supply end of cable.

General Electrical Guidelines

•  Whenever possible avoid running control cables in 

the same conduit with or bundled with AC power.

•   Using shielded cable, be sure to connect shield to 

ground at power supply end of the cable. Do not 

connect other end of shield.

• 

 Avoid routing flow sensor cables in close proximity to 

a variable frequency drive.

•   Recommended power and output wiring is shielded 

twisted pair 18-22 AWG control cable.

•   

Recommended voltage is 12-24 Vdc. Note that 

unregulated power supplies can vary from nameplate 

voltage by a considerable amount, especially with AC 

line voltage fluctuation. Therefore 24V power supplies 

must be regulated.

See the Connections diagrams on the following pages for 

the appropriate terminals.

Power

A 12 - 24 Vdc power supply capable of at least 250 mA 

current output is needed.

Output

The  standard  output  is  pulses  with  flow  in  the  forward 

direction (Reverse flow output is optional [-15] ). Electrically 

it is an open collector opto isolated switch. The output is 

not internally powered.

Note: 

This output is limited to 6 mA at 30 Vdc maximum.

Caution: 

The EX100/200-Series have  

strong start and run currents.  When using 

solar panels and VRSLA batteries as a 

power source, use caution to insure the EX-

series sensor has the -50 Low-power Option and that 

all Seametrics products on the power circuit receive 

sufficient voltage and current under all conditions.  

Failure to do so will lead to unreliable operation and 

possible damage to the unit/s.  Please reference 

the technical bulletin, ‘Solar and Battery-Power 

Guildlines’ available on our website: www.seametrics.

com

ELECTRICAL CONNECTIONS

Earth Ground

Grounding  

Clamp

Place Ferrite 

Bead Here

Housing Screw

Metallic Pipe

Содержание EX100 Series

Страница 1: ...PROUDLY MADE IN THE USA C e rtified Compa n y ISO 9001 2008 EX100 200 Series Insertion Magnetic Flow Meter Instructions EX11x EX21x EX15x EX25x...

Страница 2: ...ections General Electrical Guidelines Page 11 Power Page 11 Output Page 11 Grounding Guidelines Page 11 Connection Diagrams Counter or PLC Page 12 A055 4 20 mA Output Page 12 FT520 Controller Page 12...

Страница 3: ...es converted using any of the Seametrics family of indicators and converters A modular system of electronics can be installed directly on the flow sensor or mounted remotely The FT430 externally power...

Страница 4: ...Valve Assembly 15x 25x only Bronze stainless optional with bronze ball valve Fitting Size Required 11x 21x 1 5 FNPT 15x 25x 2 FNPT Maximum Pressure 200 psi 14 bar Temperature Ambient 0 to 160 F 17 to...

Страница 5: ...are not recommended for installation downstream of a boiler feedwater pump where installation fault may expose the flow sensor to boiler pressure and temperature Maximum recommended temperature is 20...

Страница 6: ...ht If initial installation is performed on an unpressurized pipe cut a minimum 1 3 4 hole in the pipe If possible measure the wall thickness and write it down for use in depth setting Then install the...

Страница 7: ...ension D one more time 5 Fully tighten the compression nut Record your settings Once you have the meter set up and operational it is important to record you meter settings and save them future referen...

Страница 8: ...37 1 031 1 218 Stainless Steel 10S 0 120 0 120 0 134 0 148 0 165 0 180 0 188 0 188 0 188 0 218 0 250 0 312 0 312 Stainless Steel 40S 0 216 0 237 0 280 0 322 0 365 0 375 0 375 0 375 0 375 0 375 0 375 0...

Страница 9: ...age 9 seametrics com INSTALLATION Straight Pipe Recommendations X diameter 5X 10X Reduced Pipe Two Elbows In Plane Two Elbows Out Of Plane Expanded Pipe Swirling Flow Propeller Meter Partially Open Bu...

Страница 10: ...ault may expose the flow sensor to boiler pressure and temperature Maximum recommended temperature is 200 F Full Pipe Recommendations Better Installation Possible Problem Air can be trapped Allows air...

Страница 11: ...cable be sure to connect shield to ground at power supply end of the cable Do not connect other end of shield Avoid routing flow sensor cables in close proximity to a variable frequency drive Recomme...

Страница 12: ...dc Power Forward Output EX SERIES AO55 EX SERIES Sensor 4 20 mA 4 20 mA 24 Vdc Power 12V SEN1 G SEN2 EX SERIES 24 Vdc Power Power Forward Output FT520 Reverse Output Option 15 only Reverse Output Opti...

Страница 13: ...See Dual FT430 440 Diagram for an example of bidirectional connections _ _ _ _ _ _ _ S _ _ _ Power Pulse Out 2 Sensor Input Pulse Out 1 Scaled Scaled Reverse Output Option 15 only Power Forward Output...

Страница 14: ...ions Green White Black Red 12 24 Vdc Power _ S _ _ _ _ _ S _ _ _ Power Pulse Out 2 Sensor Input Pulse Out 1 Scaled 430 Pass Thru 440 Scaled 24 Vdc Power DL76 FT430 440 EX SERIES Sensor Input Reverse O...

Страница 15: ...es it may be necessary to adjust the flow meter under no flow conditions after it has been installed This should only be done if the indicated flow is low near the lower cutoff Zero Adjustment To perf...

Страница 16: ...h 100414 100414 7 Strain relief kit large includes 1 101850 101850 9 Tube Not field replaceable 10 Compression nut 100064 brass 100084 ss 11 Compression ferrule 100358 12 Adapter 100845 brass 100846 s...

Страница 17: ...ons Fluid conductivity 20 S cm Select another flow meter Output pulses incorrect Missing or incorrect ground wire Check for proper ground Incorrect depth setting Check depth setting see page 7 Fluid c...

Страница 18: ...Seametrics which cause damage to the products or cause abnormally frequent service calls or service problems h A new warranty period shall not be established for repaired or replaced material products...

Страница 19: ...EX100 200 SERIES INSTRUCTIONS Seametrics 253 872 0284 Page 19 seametrics com NOTES...

Страница 20: ...Seametrics 19026 72nd Avenue South Kent Washington 98032 USA P 253 872 0284 F 253 872 0285 1 800 975 8153 seametrics com LT 65200196r2 1 20161230 12 30 16...

Отзывы: