Error / Acknowledge Indication
If the key sequence is invalid, or an out of bounds value is attempted to be set, the light
flashes 5 times for 1 second. (The command then needs to be sent from the start.)
The light flashes 5 times for 1 second.
When a key sequence has been entered successfully the light will respond
acknowledgement with a long 1 second flash.
Configuration Settings
The intensity and flash codes can be changed using the IR Remote Control. The lamp
intensity and flash code settings are set to the last detected change, carried out with the IR
Remote Control.
Example #1:
If the Intensity is set to 10nm via the PC Configuration Tool, and is then set to
8nm using the IR Remote Control, the intensity setting will change to 8nm. It the intensity is
then changed via the PC Configuration Tool, eg 7nm, then the intensity will be set to 7nm.
Example #2:
The flash code is set using the PC Configuration Tool to 0.5sec ON, 4.5sec
OFF. After disconnecting the PC Configuration Tool the operator then can change the flash
code using the IR Remote to any three number sequence as found in the manual appendix.
The new flash code is now configured to the selected flash code. Eg 163 (0.5sec ON, 0.5sec
OFF).
Use the IR Remote to read the flash code and it will flash with the 3 number sequence that
matches the flash codes in the Appendix.