![Sealite GSM Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/sealite/gsm/gsm_owners-manual_1227791015.webp)
GSM Cell-Phone
Monitoring & Control System
Latest products and information available at
www.sealite.com
15
Alarm Sources Summary
All of the following alarm conditions can be programmed via SMS text message to be either ENABLED
or DISABLED.
If an alarm condition that has been enabled occurs, an SMS text message will be automatically sent to
all the cell phone numbers listed in the Report List.
Command
Parameter Function
Enable
Command
Format
Disable
Command
Format
add
alarm
batlo
Alarm SMS “batlo” is asserted
when the battery voltage falls to
a low level (flat battery). An alarm
condition will be set if the system
battery voltage falls below 10.0V
indicating a flat battery. The lantern
will be turned OFF if the battery
voltage falls below 10.0V.
add alarm
batlo
delete alarm
batlo
nodata
Alarm SMS “nodata” is asserted
when the GSM module loses
communication with the lantern
circuitry.
add alarm
nodata
delete alarm
nodata
LED Failure
Alarm SMS LED Failure is asserted
when an individual LED in the
lantern fails and the lantern sends a
signal to the GSM.
NOTE: only available on certain
lanterns.
add alarm
ledfail
Delete alarm
ledfail
rotation
Alarm SMS Rotation is asserted
when the external rotation sensor
detects a failure in a 3rd Party
Rotating Table. The Lantern sends a
signal to the GSM.
NOTE: only available on certain
lanterns
add alarm
rotation
Delete alarm
rotation
temp
Alarm SMS Temp is asserted when
an Internal or External Temperature
Sensor falls out of a pre-set
boundary and the lantern sends a
signal to the GSM.
NOTE: only available on certain
lanterns.
add alarm
temp
Delete alarm
temp
Mains fail
Alarm SMS Mains Fail is asserted
when AC power is disrupted and the
lantern sends a signal to the GSM.
NOTE: only available on certain
lanterns
add alarm
mains
Delete alarm
mains