NOTE: 

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental    

 

capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the  

 

 

appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user    

 

maintenance shall not be made by children without supervision.

 

2. 

INTRODUCTION

Manufactured from heavy duty corrosion resistant materials in either stainless steel or polypropylene. Suction pump suitable for drawing brackish 

water up to 8 metres. Includes a removable filter for easier maintenance.

3. 

SPECIFICATION

4.  INSTALLATION

 

The pump may be gravity or suction fed. Gravity feed is the preferred arrangement as this 

 

will place less strain on the long term operation of the pump. Depending on the installation, 

 

various plumbing accessories will be required. Determine requirements and if necessary 

 

contact your local Sealey dealer for advice on obtaining appropriate accessories. 

4.1.   

 PUMP

4.1.1.   

Locate pump in a suitable area, ensuring that there is good air circulation. Externally the

 

pump is not designed to be totally waterproof to protect it from possible wet situations.

 

Bolt the pump to a flat horizontal surface with the outlet pipe (fig.1A) pointing vertically 

 upwards.

4.2.    

GRAVITY FEED

 (preferred arrangement when the feed water level is above the pump 

 inlet).

4.2.1.1. 

   Fit an isolation valve to the gravity feed pipe. Valve is used to turn water off and to restrict 

 the flow if required. 

4.3.    

SUCTION FEED

 (when the feed water level is lower than the pump inlet).

4.3.1.   

If the distance (HA) is less than 4mtr; use a feed pipe of 1” diameter.

4.3.2.   

If the distance (HA) is greater than 4mtr; use a feed pipe of greater than 1” diameter. 

4.3.3.   

The distance (HA) must not exceed 8mtr. 

4.3.4. 

  

Connect a filter valve to the feed pipe inlet (fig.1B) to ensure water will be retained in

 pump system.  

 

 

4.3.5.   

Connect other end to pump inlet. The filter should be situated approximately 0.5mtr 

 beneath the water level.

4.3.6.   

We advise that a check valve is installed directly on the delivery line, to prevent the pump being damaged by “water hammer” and that a  

 

cut-off valve is also installed (downstream from check valve) to facilitate maintenance work. 

 

 NOTE:

 With both gravity and suction feed ensure that the supply inlet pipe is the same height as the pump inlet or lower, and that, if  

 

  connecting to a drinking water supply, the water authority regulations are adhered to.

5.  OPERATION

 

‰

  

WARNING!

 Ensure that you read, understand and apply Section 1 Safety Instructions.

5.1.    

Check inlet water pipe is turned on or that inlet suction feed is placed in the water supply to a depth of at least 0.5mtr.

5.2.    

If using gravity feed, check and set the outlet restriction valve as necessary.

5.3. 

  

Prime the pump via the filler hole (fig.1C). Replace cap and ensure that there are no leaks. Open any closing/cut-off devices on the    

 

delivery tube.

5.4. 

  

To run the pump, plug into the electrical mains supply and press the switch located on the side of the pump to ‘I’.

5.5.    

If, for any reason, the motor should overheat, a thermal circuit breaker will automatically activate and stop the pump. If this happens,  

 

switch the mains power off and unplug. Check the reason for overheating and remedy the problem. If the pump is not switched off, the  

 

motor will cool, after which it will automatically re-start.

6.  MAINTENANCE

 

‰

  

WARNING!

 

Apart from the exceptions listed below, mechanical and electrical service maintenance and repair must only be  

  undertaken by an authorised service agent. Failure to observe this rule may be dangerous and will invalidate your warranty.

 

‰

  

WARNING!

 

Ensure that the pump is disconnected from the mains power supply before attempting any service or maintenance.

6.1. 

  

Keep all parts of the pump clean. Rinse and drain via draining hole (fig.1D) when not in use. Check all electrical connections to ensure  

 

that they are in good condition.

6.2.    

If pump becomes blocked, remove the inlet pipe and direct a jet of water through the outlet whilst running the motor for several seconds.

 

  Repeat this operation until the blockage has been expelled. If this action does not remedy the problem contact your local Sealey service  

 

 agent.

6.3. 

  

Unscrew the lid of the inlet filter (anticlockwise) remove the filter gauze and clean it in running water, see fig.1.E. Replace.

6.4. 

  

Clean any accessory filters according to the manufacturer’s instructions.

Model no

WPS060.V3

WPS062S.V2

Cut-out

Manual

Manual

Outlet OD

1”BSP

1”BSP

Maximum output

3000ltr/hr

3300ltr/hr

Maximum head

35mtr

38mtr

Maximum suction height

8mtr

8mtr

Maximum particle size

1mm

1mm

Motor power

650W

800W

Supply

230V

230V

fig.1