3.  SPECIFICATION

 

Model No:

. . . . . . . . . . . . . . . . . .

VEN200.V4

. . . . . . . . . . . . . . . . . .

VEN250.V2

. . . . . . . . . . . . . . . . . . . . . . .

VEN300.V3

 

Power:. . . . . . . . . . . . . . . . . . . . .180W  . . . . . . . . . . . . . . . . . . . . . . 300W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .500W

 Supply:  . . . . . . . . . . . . . . . . . . . .230V~50Hz. . . . . . . . . . . . . . . . . . 230V~50Hz . . . . . . . . . . . . . . . . . . . . . . . 230V~50Hz

 

Fan Diameter: . . . . . . . . . . . . . . .200mm  . . . . . . . . . . . . . . . . . . . . . 250mm  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300mm

 

Fan Speed:  . . . . . . . . . . . . . . . . .2800rpm . . . . . . . . . . . . . . . . . . . . 2800rpm  . . . . . . . . . . . . . . . . . . . . . . . . . . . 2800rpm

 

Max. Airflow:

  . . . . . . . . . . . . . . . .25m³/min(883cfm). . . . . . . . . . . . . 45m³/min(1590cfm) . . . . . . . . . . . 65m³/min(2225cfm)

 

Static Pressure:. . . . . . . . . . . . . .3.1mbar  . . . . . . . . . . . . . . . . . . . . 3mbar  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.9mbar

 

Noise Level:  . . . . . . . . . . . . . . . .

61dB(A)

  . . . . . . . . . . . . . . . . . . . .

66dB(A)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

61dB(A)

 

IP Rating:  . . . . . . . . . . . . . . . . . .IP55  . . . . . . . . . . . . . . . . . . . . . . . IP55  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IP55

 

Replacement Ducting (5mtr):. . . .VEN200AK1 . . . . . . . . . . . . . . . . .  VEN250AK1  . . . . . . . . . . . . . . . . . . . . . VEN300AK1

 

Replacement Ducting (10mtr)  . . .VEN200AK2 . . . . . . . . . . . . . . . . .  VEN250AK2  . . . . . . . . . . . . . . . . . . . . . VEN300AK2

 

Overall efficiency (n):

. . . . . . . . . .45.8% . . . . . . . . . . . . . . . . . . . . . . 42.8%  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51%

 

Measurement category:. . . . . . . .C. . . . . . . . . . . . . . . . . . . . . . . . . . C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C

 

Efficiency category:

. . . . . . . . . . .static . . . . . . . . . . . . . . . . . . . . . . . static . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . static

 

Efficiency grade:

  . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . . . . . . 40  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

 

Specific ratio:

. . . . . . . . . . . . . . . .0.81  . . . . . . . . . . . . . . . . . . . . . . . 0.88. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.83

4.  OPERATION

4.1.    

To extract air: attach the ducting (fig.1) to the inlet side of the ventilator, 

 

ensuring a tight fit. Secure by pulling the string tight and knotting it.

 

Locate the other end of the ducting in the area from which you wish to 

 

extract air.

4.2.    

To ventilate: attach the ducting to the outside side of the ventilator and 

 

locate the other end of the ducting in the area that you wish to ventilate.

NOTE: 

The ducting has locating lugs attached to it; these can be used to

 

suspend the ducting if required.

4.3.    

Connect the mains plug to a suitable electric supply

.

4.4.    

Move the toggle switch to start the unit; select a low or high fan speed 

 

as required.

fig.1

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

WEEE REGULATIONS

Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment 

(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid 
waste authority for recycling information.

ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 
according to local regulations.

Original Language Version

© Jack Sealey Limited

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call 

our technical team on [email protected] or 01284 757505.

Important

: No Liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.

VEN200.V4, VEN250.V2, VEN300.V3     Issue: 1    16/04/21

Отзывы: