background image

instructions for

DIGITAL DIESEL & FLUID FLOW METER

model no: 

Tp101.v2

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

 

‰

  

WARNING! 

ensure health & safety, local authority, and general workshop practice regulations are strictly adhered to when using this  

 equipment.

 

9

   familiarise yourself with product application and limitations, as well as the specific potential hazards peculiar to this product.

 

9

   maintain the meter in good condition (use an authorised service agent).

 

9

   replace or repair damaged parts. use genuine parts only. non authorised parts will invalidate the warranty.

 

9

   use only to meter diesel fuel, kerosene, petrol, water, windscreen washer or water/urea solutions. 

 

9

   ensure safety eye protection and protective clothing are worn when using this product.

 

9

   Keep the work area clean, uncluttered and ensure there is adequate lighting.

 

9

   maintain correct balance and footing. ensure the floor is not slippery and wear non slip shoes.

 

9

   Keep children and unauthorised persons away from the working area.

 

9

   After use, drain any fluids from the equipment before storage. 

 

9

   dispose of waste liquids in accordance with local authority regulations.

 

8

  

DO NOT 

exceed the maximum pressure of 50bar.

 

8

  

DO NOT

 use the equipment near open flames.

 

8

  

DO NOT 

smoke whilst using this equipment. 

 

8

  

DO NOT

 use for corrosive fluids.

 

8

  

DO NOT 

dismantle, tamper with or adapt the equipment for any purpose other than for which it is designed.

 

8

  

DO NOT 

use the unit if it has been dropped or mishandled, check the unit to ensure there is no damage.

 

8

  

DO NOT 

use taper connections, use parallel connectors only.

 

8

 

  DO NOT 

use compressed air on the turbine, the excessive rotation will damage the unit.

 

9

   Keep the meter clean and store in a safe dry, childproof location. 

 

‰

   

WARNING! DO NOT

 allow uncontrolled discharge of fluids thus polluting the environment. All liquids must be disposed of according to 

 

local authority regulations.

2.  INTRODUCTION

robust rubber housing with integral digital electronic metering. easy to read large, four digit, 28mm high lcd display calibrated in litres, quarts, 

pints and gallons. features flow rate indication. 1” x 1” BsP male/female fitting. Powered by 2 x AAA batteries (supplied). iP65 rated protection.

3.  SpECIFICATION

model no: ...................................................................tP101.V2

flow rate: ................................................................7-120ltr/min

4.  OpERATION

 

‰

  

WARNING!

 

DO NOT

 use the meter without a filter installed BEFORE the meter.

  

4.1.    

Installation refer to fig's 1 & 3

4.1.1. 

  

This is a bi-directional meter with 1” threaded male & female ports. The meter can be fixed in any position - fixed inline or  

 

 

mobile on a control nozzle.

4.1.2.   

remove the four screws (2) and separate the card housing (5) from the turbine assembly (6).

4.1.3. 

  

Rotate the card housing in any of the four positions as shown in fig.1 and tighten the card housing with four screws (2)

refer to 

instruction

manual

fig.1

tP101.V2  | issue:1   30/11/17

Original Language Version

© Jack sealey limited

Содержание TP101.V2

Страница 1: ... liquids in accordance with local authority regulations 8 8 DO NOT exceed the maximum pressure of 50bar 8 8 DO NOT use the equipment near open flames 8 8 DO NOT smoke whilst using this equipment 8 8 DO NOT use for corrosive fluids 8 8 DO NOT dismantle tamper with or adapt the equipment for any purpose other than for which it is designed 8 8 DO NOT use the unit if it has been dropped or mishandled ...

Страница 2: ... The meter features two buttons RESET and CAL which individually perform two main functions and together perform other secondary functions 4 4 1 1 RESET key is used to reset the Batch TOTAL and Reset TOTAL 4 4 1 2 CAL key is used to enter the calibration mode 4 4 1 3 Combination of RESET CAL keys is used to change the unit of measurement and other secondary functions 4 4 2 Turbine Assembly it has ...

Страница 3: ...our combinations of units of measurement as shown in fig 7 4 8 3 Press CAL key for more than 2 seconds to store new settings The METER will return to Standby Mode see fig 8 Note No new calibration is required after changing the Unit of Measurement 4 9 Normal Dispensing Mode see fig 9 4 9 1 While the media is flowing through the meter Batch Total and Reset Total are displayed at the same time 4 9 2...

Страница 4: ...the display page is showing the Reset TOTAL is shown press and hold the Reset key again until the Resettable TOTAL turns to zero see fig 17 and fig 18 4 11 1 4 Finally the page with the new Reset TOTAL is displayed see fig 19 4 12 Calibration 4 12 1 In standby mode press and hold the CAL key to see the current calibration factor Factory K Factor Factory set default factor It is equal to 1 indicate...

Страница 5: ...isplayed 4 12 4 1 In field Calibration Sequence 1 Wait until the METER returns into Standby display shows TOTAL see fig 22 2 Press CAL key for more than 2 seconds The METER enters calibration mode and shows CAL The words FACT or USER indicate which factor factory or user is currently in use see fig 23 3 Press the meter and hold the RESET key The METER shows FIELD and the Batch Total is zero The me...

Страница 6: ... basis of several performed dispensing operations this can be corrected by applying a correction to the current calibration factor as shown below New cal Factor Old Cal Factor x 100 E 100 Example Error percentage found E 0 3 value observed is 0 3 less than actual CURRENT calibration factor 1 000 New USER K FACTOR 1 000 100 0 3 100 1 000 100 0 3 100 1 003 1 Wait until the METER enters Standby displ...

Страница 7: ...fixed battery symbol appears In this condition the METER continues to operate correctly but the fixed icon warns the user that it is time to change the batteries see fig 42 5 2 1 2 If meter operation continues without changing the batteries the second battery alarm level will be reached which will prevent any operation In this condition the battery icon starts to flash and is the only one to remai...

Страница 8: ... 12 months from purchase date proof of which is required for any claim Weee Regulations Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information Batte...