background image

   

1.1. 

PERSONAL PRECAUTIONS

  When using the analyser, please observe all normal safety rules concerning

:

 

Protection against the dangers of electric current.

 

Protection of the analyser against misuse.

  Full compliance with safety standards can only be guaranteed if used with the test leads supplied. If necessary, these must be replaced with genuine  

 

 

Sealey  leads with the same electronic ratings. Failure to do so will invalidate the warranty.

 

DO NOT

 use leads if damaged or if the wire is bared in any way. 

1.2.  

GENERAL SAFETY INSTRUCTIONS

  Familiarise yourself with the application and limitations of the analyser as well as the potential hazards. 

IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN.

  When the analyser is linked to a measurement circuit, do not touch unused analyser terminals.

  When the scale of the value to be measured is unknown set the selector to the highest range available.

  Before rotating the range selector to change functions, disconnect test leads from the circuit under test.

  WARNING! 

Never perform resistance measurements on live circuits. 

Only measure on disconnected circuits.

  Always be careful when working with voltages above 60V DC or 30V AC. Keep fingers behind the probe barriers whilst measuring.

 

When not in use, store the analyser carefully in a safe, dry, childproof location. Storage temperature range -10

°

C to 50

°

C.

 

Never apply voltage or current to the analyser that exceeds the specified maximum.

 

WARNING! 

Do not make current measurements on the 10A scale for longer than 10 seconds in every 15 minutes. Exceeding 10 seconds may cause damage  

 

to the analyser and test leads.

INStruCtIONS FOr:

12 FUNCTION DIGITAL AUTOmOTIvE ANALYSER

MODEL No:

TA101

thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, 

give you years of trouble free performance.

1.  SAFETY INSTRUCTIONS

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREmENTS, WARNINGS & CAUTIONS. USE THE PRODUCT 

CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO mAY CAUSE DAmAGE AND/OR PERSONAL INJURY AND WILL 

INvALIDATE THE WARRANTY. PLEASE KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

2.  INTRODUCTION

 

Functions

Function

Test Range

AC Voltage

326mV - 1000V

326

Ω  − 

32.6M

326

µ

10A

2cyl 180°- 8cyl 45°
0  -  3260rpm  and

0  -  3260rpm  x10

326

µ

10A

-20°C to 750°C

-4°F  to  1400°F

0 - 99.9%

typically 

1mA

Durable bi-composite case and integral stand suitable for the toughest 

workshop conditions. Large, hi-contrast LCD display with 18mm high 

digital read-out and analogue bar graph. Includes auto-ranging, 

data-hold, auto-polarity, auto-power-off and low battery display 

functions. Bar graph simplifies lambda sensor testing. Supplied with  

capped test probes and K-type thermocouple. 

C o n n e c t i o n s

Frequency

Diode test
Continuity test

DC 

Current

AC 

Current

<50 Ohms
320Hz  -  32kHz

t a c h o m e t e r

t e m p e r a t u r e

Duty 

Cycle

r e s i s t a n c e

Dwell 

Angle

3.26V - 750V

DC Voltage

v

RPm  +  COm

v

RPm  +  COm

µ

AmA  /  10A  +  COm

v

RPm  +  COm

Display

3 3/4 digits LCD display with a max. reading 3260. Digital height 18mm. 

 

Polarity:

 

Auto polarity indication. 

measurement Rate:

  

3 times per second.

Over Range Indication

:   “OL” displayed on the LCD.

Low Battery Indication

:  the      symbol is displayed when the battery voltage drops below the operating level.

Auto-Power- Off

Analyser automatically shuts down after approx. 10 minutes of inactivity. 

 

Press 

“Hold”

 to switch on again.

Operating Environment

:  0°C to 40°C (32°F to 104°F) at <75% relative humidity.

Storage Environment

-10°C to 50°C (14°F to 122°F) at <75% relative humidity.

Power

Single standard 9 Volt battery (PP3).

Fuse

F10A/250V and F0.5A/250V.

Dimensions

200 x 93 x 50 mm.

Weight Approx

Approx. 400g including battery and holder.

1. 

OFF Position

2. 

AC/DC voltage (+10)

3. 

Resistance/Diode/Audible Continuity (+10) 

4. 

AC/DC Current (+10)

5. 

Frequency

6. 

Tachometer

7. 

Duty Cycle

8. 

Temperature

9. 

Dwell Angle

10.  Select AC/DC/Resistance/Diode/Continuity

Function Guide (Fig.2)

Fig.1

Fig.2

Original Language Version

tA101   Issue No.2 - 19/12/11

Содержание TA101

Страница 1: ...IONS CAREFULLY NOTE THE SAFE OPERATIONAL REQUIREMENTS WARNINGS CAUTIONS USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED FAILURE TO DO SO MAY CAUSE DAMAGE AND OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY PLEASE KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE 2 introducTION Functions Function Test Range AC Voltage 326mV 1000V 326Ω 32 6MΩ 326µA 10A 2cyl 180 8cyl 45...

Страница 2: ... are sure that you understand the procedures is it safe to proceed with testing WARNING Risk of electrocution High voltage circuits both AC and DC are very dangerous and should be measured with great care Operating temperature range 0 C to 40 C Remember to turn off analyser when measurement is completed Note If OL appears in the display during a measurement the value exceeds the range you have sel...

Страница 3: ...ment 4 11 1 Insert the black test lead into the negative COM socket and the red test lead into the positive VΩRPM socket 4 11 2 Turn the function dial to the desired position that corresponds with the correct number of cylinders for the engine being tested 4 11 3 If the vehicle uses a DIS ignition system with no distributor connect the red test lead to the TACH tachometer signal line which is conn...

Страница 4: ...s accessories and packaging should be sorted taken to a recycle centre and disposed of in a manner which is compatible with the environment When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information WARNING Do not dispose of by fire This could result in an explosion Before disposing of batter...