For a positive-grounded vehicle, connect the NEGATIVE (BLACK) 

clamp from the jump starter to the NEGATIVE (NEG, N, -) 

ungrounded post of the battery. Connect the POSITIVE (RED) clamp 

to the vehicle chassis or engine block away from the battery. Do not 

connect the clamp to the carburettor, fuel lines or sheet-metal body 

parts. Connect to a heavy gauge metal part of the frame or engine 

block.

4.8 

When finished using the jump starter, remove the clamp from the 

vehicle chassis and then remove the clamp from the battery terminal. 

Disconnect the clamps from the unit.

5.  FEATURES

1. 

LCD display

2. 

 Display button

3. 

Smart cable green and red 

LEDs 

4. 

ON/OFF switch

5. 

Micro USB input port  

for recharging

6. 

3A   input/output USB port

7. 

Quick Charge™    

3.0 USB output port

8. 

2.4A USB output port

9. 

SSL-JC smart cable  

with battery clamps

10. 

Jump start output   

 socket

11. 

LED light

Not shown:

12. 

Micro USB-USB  

  charging cable

13. 

Carrying case

Содержание SL69S

Страница 1: ...NUAL AND READ BEFORE USE This manual will explain how to use the unit safely and effectively Please read and follow these instructions and precautions carefully MODEL SL69S Jump Starter OWNER S MANUAL SL69S issue 2 10 11 06 02 20 ...

Страница 2: ... WARNING RISK OF EXPLOSIVE GASES WORKING IN THE VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL OPERATION IT IS IMPORTANT THAT YOU FOLLOW THESE INSTRUCTIONS EACH TIME YOU USE THE UNIT To reduce the risk of battery explosion follow these instructions and those published by the battery manufacturer and the manufacturer of any equipment you intend to use ...

Страница 3: ...reduce the risk of a battery explosion follow these instructions and those published by the battery manufacturer and the manufacturer of any equipment you intend to use in the vicinity of the battery Review the cautionary markings on these products and on the engine 1 11 Do not set the unit on flammable materials such as carpeting upholstery paper cardboard etc 1 12 Never place the unit directly a...

Страница 4: ...Y CAUSE A BATTERY EXPLOSION TO REDUCE THE RISK OF A SPARK NEAR THE BATTERY 4 1 Plug the clamps into the unit and then attach the output cables to the battery and chassis as indicated below Never allow the output clamps to touch each other 4 2 Position the DC cables to reduce the risk of damage by the bonnet door and moving or hot engine parts NOTE If it is necessary to close the hood during the ju...

Страница 5: ...t of the frame or engine block 4 8 When finished using the jump starter remove the clamp from the vehicle chassis and then remove the clamp from the battery terminal Disconnect the clamps from the unit 5 FEATURES 1 LCD display 2 Display button 3 Smart cable green and red LEDs 4 ON OFF switch 5 Micro USB input port for recharging 6 3A input output USB port 7 Quick Charge 3 0 USB output port 8 2 4A ...

Страница 6: ... of the charging cable into a charger s USB port 2 Plug your charger into a live AC or DC power outlet 3 The LCD display will light the digit begins to flash and show IN indicating that charging has begun 4 The jump starter will fully charge in 7 8 hours When the unit is fully charged the display will show 100 5 When the battery is fully charged disconnect your charger from the outlet and then rem...

Страница 7: ...fer to section 10 Troubleshooting When the condition is corrected the smart cable will automatically reset NOTE Cold weather may affect the performance of the jump starter s lithium battery If you hear only a click and the engine does not turn over try the following With the jump starter connected to the car battery and the green LED illuminated on the smart cable turn on all lights and electrical...

Страница 8: ... ON position 2 Hold down the display button for 3 seconds 3 Once the LED light is on press and release the display button to cycle through the following modes Steady glow Flash for an SOS signal Flash in strobe mode 4 When finished using the LED light press and hold the display button until the light turns off 5 Slide the ON OFF switch to the OFF position 6 Recharge the unit as soon as possible af...

Страница 9: ...Red LED Green LED off beeps once per second The vehicle battery voltage is lower than 10 5V User can connect to jump starter and turn key to jump start the vehicle When cable is correctly connected to both battery and jump starter Green LED blinking Red LED off no beep Fake high battery voltage is detected but reverse charging protection did not activate User can turn key to jump the vehicle Smart...

Страница 10: ...en LEDs beeps once per second Temperature protection NOTE When the condition is corrected the smart cable will automatically reset 11 SPECIFICATIONS Auxiliary output USB x2 5V 2 4A 5V Quickcharge 3 0 Type C 5V 3A Cable clamp length 440mm Capacity 15Ah 3 2V 3 75Ah 12 8V Max current 1000A Max starting capacity 6L Petrol 3L Diesel Size W x D x H 95 x 40 x 185mm ...

Страница 11: ...be sorted taken to a recycling centre and disposed of in a manner which is compatible with the environment When the product becomes completely unserviceable and requires disposal drain any fluids if applicable into approved containers and dispose of the product and fluids according to local regulations Note It is our policy to continually improve products and as such we reserve the right to alter ...

Страница 12: ...ce with the above Directive s Technical file compiled by Jack Sealey Ltd Being the responsible person appointed by the manufacturer Signed Date Name Position Place Bury St Edmunds Lithium Jump Starter Power Pack SL69S v1 2014 30 EU EMC Directive 2011 65 EU RoHS Directive References to harmonised standard s EN 55032 2015 EN 55035 2017 25 July 2018 Steve Buckle Marketing Director XVII2813 Sealey Gro...