background image

2.  INTRODUCTION

 

Model No. SD004

 - 60W Soldering Station with rapid heat up. MCU Controlled temperature calibration. LCD Display screen  

 

 

showing current temperature and settings. User-friendly menu. Maintains temperatures between 150-450°C. Capable of pre-setting  

 

three frequently used temperatures. Supplied with soldering sponge and soldering iron stand.

3.  SPECIFICATION

Model No:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . SD004

Frequency: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

50Hz

Heating Element Voltage:. . . . . . . . . . . . . . . . .

26V AC

Power:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

60W

Supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V

Temperature Accuracy:. . . . . . . . . . . . . . . . . . . .

±10°C

Temperature Range:. . . . . . . .

150-450°C(302-842°F)

Temperature Stability:. . . . . .

±2°C (in still air, no load)

Tip-to-Ground Resistance: . . . . . . . . . . . . . . . . . .

< 2Ω

Tip-to-Ground Voltage: . . . . . . . . . . . . . . . . . . . < 2mV

Replacement tip . . . . . . . . . . . . . . . . . . . . . . SD003ST

Replacement heating element . . . . . . . . . . .SD004HE

Replacement iron and cable  . . . . . . . . . . . . SD004IC

Optional extra:

 

Tip thermometer................................SD003TT

4.  OPERATION

 

 

 

 NOTE: 

Dampen the sponge wiper before using the soldering station.

4.1.    

CONNECTION

4.1.1.   

Push the DIN plug attached to the iron lead into the socket on the front panel of the control unit.

4.1.2.   

Plug the power cable into the mains power supply after ensuring that it is to the correct standard.

4.2. 

  

SWITCHING ON (fig.1)

4.2.1.  

 

Switch the on/off switch to the ‘

     

’ setting. Switch is located on the side of the unit. 

4.2.2.   

The current set temperature will be displayed for 3 seconds.

4.2.3.   

After a further 3 seconds, the display will show the real-time temperature of the tip and charging activity if heating is required.

NOTE:  

The number of bars shown by the analogue current display (fig.1.7) represent the current being applied to the tip.

4.3. 

  

TEMPERATURE SETTING (fig.2, fig.3, fig.4)

4.3.1. 

  

The factory set default temperatures stored by buttons: 1, 2 and 3 are 200,300 and 400°C respectively.

4.3.2.   

Select button 1, 2 or 3 to initiate required stored temperature.

4.3.3. 

  

With the normal settings applied, the temperature can be adjusted by means of the ▲ and▼ buttons (fig.3).

4.3.4. 

  

The display will go to ‘SET’ and the required temperature will either increase or decrease. Holding the button down will allow rapid  

 

adjustment.

4.3.5.   

When the button is released, the display will revert to ‘real’ to illustrate the current temperature.

  

S

D004              Issue 1        19/08/2019

Original Language Version

© Jack Sealey Limited

1 . . . . . . . . . . . . . . . . . . . . . . . . . Set Temperature Mode

2 . . . . . . . . . . . . . . . . . . . .Real-Time Temperature Mode

3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Calibration Mode

4 . . . . . . . . . . . . . . . . . . . Temperature Stored: Channel1

5

 . . . . . . . . . . . . . . . . . . . Temperature Stored: Channel2

6

 . . . . . . . . . . . . . . . . . . . Temperature Stored: Channel3

7 . . . . . . . . . . . . . . . . . . . . . . . Analogue Current Display

8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fahrenheit Values

9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Celsius Values

10 . . . . . . . . . . . . . . . . . . . . .Real-Time Tip Temperature

fig.1

fig.2

fig.3

fig.4

Содержание SD004

Страница 1: ...in plug If in doubt contact a qualified electrician a Connect the GREEN YELLOW earth wire to the earth terminal E b Connect the BROWN live wire to the live terminal L c Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician ...

Страница 2: ... to the setting Switch is located on the side of the unit 4 2 2 The current set temperature will be displayed for 3 seconds 4 2 3 After a further 3 seconds the display will show the real time temperature of the tip and charging activity if heating is required NOTE The number of bars shown by the analogue current display fig 1 7 represent the current being applied to the tip 4 3 TEMPERATURE SETTING...

Страница 3: ...conds CAL will be displayed 4 5 5 After making any required adjustments press to save the setting 5 ERROR MESSAGES 5 1 If either of the two screens below are displayed turn the unit off and replace the heating element refer to section 7 2 H E indicates heating element failure S E indicates Sensor element failure 6 TEMPERATURE UNITS 6 1 To change the units used in the measurement of temperature hol...

Страница 4: ...d fluids according to local regulations WEEE REGULATIONS Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information Note It is our policy to continually...