sealey group, Kempson Way, suffolk Business park, Bury st edmunds, suffolk. ip32 7aR
01284 757500
01284 703534
www.sealey.co.uk
enViRonment pRotection
recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Weee Regulations
dispose of this product at the end of its working life in compliance with the eu directive on Waste electrical and electronic equipment
(Weee). When the product is no longer required, it must be disposed of in an environmentally protective way. contact your local solid
waste authority for recycling information.
BatteRy RemoVal
under the Waste Batteries and Accumulators regulations 2009, Jack sealey ltd are required to inform potential purchasers of products
containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack
Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.
note
: it is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
important
: no liability is accepted for incorrect use of this product.
Warranty
: Guarantee is 12 months from purchase date, proof of which is required for any claim.
5. inBuilt safety systems
5.1.
This jump starter is fitted with sophisticated electronic safety systems to protect the unit and the connected battery in the result of
accidental user error. Even with these protection systems in place, extreme care should be taken with the correct identification of the
system voltage and the batteries being jump started.
5.1.1.
Short circuit protection: In the event of accidentally touching the Positive and Negative clamps together while switched on, the unit
will shut off output power thereby preventing a dangerous overload situation. A small spark may still emit from the alligator clamps,
care should still be taken to not short circuit the unit around lead acid batteries
5.1.2.
Reverse Polarity Protection: If the unit is accidentally connected in the reverse polarity when switched on, the red LED on the front
panel will illuminate along with a continuous warning tone (beep). Power will not output during reverse connection, simply switch off the
main switch and correct the polarity of the connection before attempting to use again. the jump start will only detect a reverse polarity
connection when the main switch is on.
5.1.3.
24V battery connection protection: in the event of accidental connection to a 24V battery system, the jump start unit will automatically
enable its overload protection and switch power output off. the red led will illuminate on at the front panel, along with the warning tone.
even though this protection will protect the jump start from catastrophic failure, extreme care should be taken by the user to correctly
identify the type of battery to be jump started and the operating voltage of the system.
5.1.4.
over load and over temperature protection: When in use as a jump starter, if load is too big or unit is under load for too long, the red led
on front panel will flash, also the jump starter will stop output. After a period of resting time it will automatically start again.
5.1.5.
low Voltage alert – a single beep will be heard every 25 seconds when recharging is required, or approximately 60% remaining charge.
this will occur only when the main power switch is switched on.