GSS1515.V2, GSS1515G.V2 Issue: 2(I) - 13/04/17
Original Language Version
© Jack Sealey Limited
71
FIXP ADBOLT KEEPER
WITH 16mm SCREWS
B
71
FIXP ADBOLT KEEPER
WITH 3.0*10MM RIVET
A
Z19
Z21
Z21
Z20
Z22
Step 7:
Fit the panels together
Attach the side walls to the back wall, then the front wall, then the roof. Fix all the components using self tapping screws. Fix part 71
(pad bolt keeper) using 16mm self-tapping screws (diagram A) or using rivets (diagram B) ensuring the keeper lines up with the pad
bolt. Also attach parts Z19, Z20, Z21 and Z22 (Corner brace) to each corner using the self-tapping screws provided.
FIX PAD BOLT KEEPER
WITH 16MM SCREWS
FIX PAD BOLT KEEPER
WITH 3.0 X 10MM RIVETS
A
B