![Seakeeper 8000 GYRO Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/seakeeper/8000-gyro/8000-gyro_operation-manual_1223536031.webp)
OPERATION
MANUAL
Product:
Document
#:
Rev:
Page:
MODEL
8000
GYRO
90141
3
3
of
11
Section
3:
POWER
FAILURES,
ALARMS,
AND
TROUBLESHOOTING
The
alarm
will
not
clear
until
the
reset
condition
listed
on
the
table
below
is
achieved
and
the
operator
presses
the
POWER
ON/OFF
button.
The
operator
can
then
press
LOCK/UNLOCK
on
the
Display
home
page
to
continue
stabilization.
The
Gyro
will
not
automatically
switch
to
POWER
ON
and
UNLOCK.
Display
Indication
Description
Reset
condition
Troubleshooting
ALARM
1
BEARING
1
TEMP
HIGH
Bearing
1
temperature
above
80
°C
Bearing
1
temperature
below
55
°C
Refer
to
Seakeeper
Drawing
90149
&
verify:
(1)
boat
seawater
pump
is
on,
(2)
seawater
supplied
to
gyro
heat
exchanger
(3)
gyro
glycol
pump
is
running,
(4)
no
glycol
leaks.
ALARM
2
BEARING
2
TEMP
HIGH
Bearing
2
temperature
above
80
°C
Bearing
2
temperature
below
55
°C
Refer
to
Seakeeper
Drawing
90149
&
verify:
(1)
boat
seawater
pump
is
on,
(2)
seawater
supplied
to
gyro
heat
exchanger
(3)
gyro
glycol
pump
is
running,
(4)
no
glycol
leaks.
ALARM
3
BEARING
3
TEMP
HIGH
Bearing
3
temperature
above
80
°C
Bearing
3
temperature
below
55
°C
Refer
to
Seakeeper
Drawing
90149
&
verify:
(1)
boat
seawater
pump
is
on,
(2)
seawater
supplied
to
gyro
heat
exchanger
(3)
gyro
glycol
pump
is
running,
(4)
no
glycol
leaks.
ALARM
4
BEARING
4
TEMP
HIGH
Bearing
4
temperature
above
80
°C
Bearing
4
temperature
below
55
°C
Refer
to
Seakeeper
Drawing
90149
&
verify:
(1)
boat
seawater
pump
is
on,
(2)
seawater
supplied
to
gyro
heat
exchanger
(3)
gyro
glycol
pump
is
running,
(4)
no
glycol
leaks.
ALARM
5
MOTOR
TEMP
HIGH
Motor
temperature
above
110
°C
Motor
temperature
below
85
°C
Refer
to
Seakeeper
Drawing
90149
&
verify:
(1)
boat
seawater
pump
is
on,
(2)
seawater
supplied
to
gyro
heat
exchanger
(3)
gyro
glycol
pump
is
running,
(4)
no
glycol
leaks.
ALARM
6
DRIVE
TEMP
HIGH
Temperature
of
Motor
Drive
Box
electronics
above
55
°C
Temperature
of
Motor
Drive
Box
electronics
below
45
°C
Refer
to
Seakeeper
Drawing
90149
&
verify:
(1)
boat
seawater
pump
is
on,
(2)
seawater
supplied
to
gyro
heat
exchanger
(3)
gyro
glycol
pump
is
running,
(4)
no
glycol
leaks.
ALARM
8
COOLANT
PUMP
FAULT
Coolant
pump
current
draw
less
than
0.5
A
indicating
a
bad
connection,
a
bad
pump,
or
a
lack
of
coolant.
Coolant
pump
current
draw
more
than
0.5
A.
1)
Determine
if
the
pump
is
running
by
sound
or
touch.
2)
If
the
pump
appears
to
be
running
but
is
noisy,
then
it
is
likely
that
there
is
air
in
the
glycol
loop.
Add
glycol/water
to
reservoir
until
2/3
full.
3)
If
pump
is
not
running
refer
to
Seakeeper
Drawing
90149
Cable
Block
Diagram
and
check
J2
connector
on
Gyro
Control
Box
and
pump
connector
next
to
pump.
4)
Contact
Seakeeper
distributor
for
cooling
circuit
parts
and
service.
ALARM
11
DRIVE
FAULT
Fault
signal
in
Motor
Drive
Box
(none)
1)
Verify
boat's
AC
breaker
supplying
power
to
the
Gyro
is
on.
2)
Refer
to
Seakeeper
Drawing
90149
Cable
Block
Diagram
&
check
for
AC
power.
3)
Check
motor
connector
on
Motor
Drive
Box
ALARM
12
LOW
BRAKE
PRESSURE
Hydraulic
pressure
in
brake
low
Hydraulic
pressure
in
brake
in
normal
range
1)
Check
all
hydraulic
components
for
leaks.
2)
Refer
to
Seakeeper
Drawing
90149
Cable
Block
Diagram
&
check
connectors
on
Brake
Pressure
Switches
and
on
Gyro
Control
Box.
3)
Contact
Seakeeper
distributor
for
brake
circuit
parts
and
service.
Содержание 8000 GYRO
Страница 1: ...Rev 3 JULY 2013 OPERATION MANUAL MODEL 8000 GYRO...
Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 4: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 16: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 28: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 40: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 44: ...THIS PAGE INTENTIONALLY LEFT BLANK...