T1
Voltage is applied to the drive.
T2
After a delay, the startup current is applied and the spindle
begins to turn.
T3
The accelerating current is applied, causing the spindle speed
to increase.
T4
The spindle speed is close to the final, correct value. The drive
begins to lock in speed-control circuits.
T5
The actuator-lock solenoid releases the arm.
T6
The final speed-control lock is achieved.
T7
The servo is calibrated.
T8
The servo locks in on track 0 and the drive is ready.
T1
T2
T3
T5
T4
T6
T7
T8
0
1.0
1.7
2.0
0
2
1
4
3
6
5
8
7
amps
Seconds
Figure 1. Typical startup current profile