Initial set-up information
For the initial setup connect the cables or plug into a
mounted connector (if applicable), set the drive ID on
the bus and enable or disable the I/O line terminator
resistor packs (Hawk 1LP family "W" models only).
These procedures are described in paragraphs follow-
ing. Note whether drive model number ends in W, WD
or WC.
SCSI interface cable connection
The Hawk 1LP family wide drives are SCSI interface
drives. System connection on "W" and "WD" models is
via a 68 pin SCSI connector. System connection for
"WC" models is via an 80 pin SCSI and DC power
connector. The "WC" model plugs directly into a PCB or
bulkhead mounted mating 80 pin connector. Pin 1 is
noted in Figure 2. Some cables have a contrasting color
stripe on one edge to indicate pin 1. On the Hawk 1LP
wide drives the I/O connector is keyed by virtue of its
shape. There is only one way it can mate with the
mating input connector. Strain relief is recommended at
the cable in drives using cables. Do not block system
cooling air flow in routing of cables.
16 Hawk 1LP (Wide) Installation Guide, Rev. B