Spinpoint M8 Product Manual REV 2.6
71
device shall suspend off-line data collection activity after an interrupting command and resume off-line
data collection activity after some vendor-specified event.
Bit 3 (off-line read scanning implemented bit) - If this bit is cleared to zero, the device does not support
off-line read scanning. If this bit is set to one, the device supports off-line read scanning
Bit 4 (self-test implemented bit) – If this bit is cleared to zero, the device does not implement the Short
and Extended self-test routines. If this bit is set to one, the device implements the Short and Extended
self-test routines.
Bit 7-5 (reserved).
SMART capability
The following describes the definition for the SMART capability bits. If the value of all of these bits is equal
to zero, then this device does not implement automatic saving of SMART data.
Bit 0 (power mode SMART data saving capability bit) – If the value of this bit equals one, the device
shall save its SMART data prior to going into a power saving mode (Idle, Standby, or Sleep) or
immediately upon return to Active or Idle mode from a Standby mode. If the value of this bit equals zero,
the device shall not save its SMART date prior to going into a power saving mode (Idle, Standby, or
Sleep) or immediately upon return to Active or Idle mode from a Standby mode.
Bit 1 (SMART data auto-save after event capability bit) – The value of this bit shall be equal to one for
devices complying with this standard.
Bits 2-15 (reserved).
Self-test routine recommended polling time
The self-test routine recommended polling time shall be equal to the number of minutes that is the minimum
recommended time before which the host should first poll for test completion status. Actual test time could be
several times this value. Polling before this time could extend the self-test execution time or abort the test
depending on the state of bit 2 of the off-line data capability bits.
The data structure checksum is the two’s compliment of the result of a simple eight-bit addition of the first 511
bytes in the data structure.
8.2.34.6 SMART read log sector (D5h)
This command returns the indicated log sectors to the host.
8.2.34.7 SMART return status (DAh)
This command is used to communicate the reliability status of the device to the host at the host’s request. If a
threshold exceeded condition is not detected by the device, the device shall set the Cylinder Low register to
4Fh and the Cylinder High register to C2h. If the device detects a threshold-exceeded condition, the device
shall set Cylinder Low register to F4h and Cylinder High register to 2Ch
8.2.34.8 SMART write log sector (D6h)
This command writes number of 512-byte data sectors to the indicated log sector.
Содержание Spinpoint M8
Страница 1: ...M8 Product Manual 2 5 Hard Disk Drive March 6 2013 Rev 2 6...
Страница 17: ...Spinpoint M8 Product Manual REV 2 6 11 SPECIFICATIONS Figure 3 1 Measurement Position...
Страница 26: ...Spinpoint M8 Product Manual REV 2 6 20 INSTALLATION Figure 4 7 Pin Locations on the Drive PCBA...
Страница 29: ...Spinpoint M8 Product Manual REV 2 6 23 Cover Assembly Figure 5 1 Exploded Mechanical View...