Savvio 10K.5 SAS Product Manual, Rev. D
5.2.2
Format command execution time for 512-byte sectors (minutes)
900GB
600GB
450GB
300GB
Maximum (with verify)
234
156
117
78
Maximum (without verify)
116
75
58
36
Note.
There is approximately a 1.5 increase in time to format a SED drive versus a non-SED drive of the same capacity.
5.2.3
General performance characteristics
Minimum sector interleave
1 to 1
Data buffer to/from disc media (one 512-byte logical block)*
1.00 to 1.91 Gb/s
Sustained transfer rate
89 to 160 MiB/s **
93 to 168 MB/s
SAS Interface maximum instantaneous transfer rate
600 MB/s* per port
(dual port = 1200 MB/s*)
Logical block sizes
512 (default), 520, 524 or 528.
Read/write consecutive sectors on a track
Yes
Flaw reallocation performance impact (for flaws reallocated at format time using the
spare sectors per sparing zone reallocation scheme.)
Negligible
Average rotational latency
3.0ms
*Assumes no errors and no relocated logical blocks. Rate measured from the start of the first logical block transfer to or
from the host.
** MiB/s x 1.048 = MB/s
5.3
Start/stop time
The drive accepts the commands listed in the
SAS Interface Manual
less than 3 seconds after DC power has
been applied.
If the drive receives a NOTIFY (ENABLE SPINUP) primitive through either port and has not received a START
STOP UNIT command with the START bit equal to 0, the drive becomes ready for normal operations within 30
seconds (excluding the error recovery procedure).
If the drive receives a START STOP UNIT command with the START bit equal to 0 before receiving a NOTIFY
(ENABLE SPINUP) primitive, the drive waits for a START STOP UNIT command with the START bit equal to 1.
After receiving a START STOP UNIT command with the START bit equal to 1, the drive waits for a NOTIFY
(ENABLE SPINUP) primitive. After receiving a NOTIFY (ENABLE SPINUP) primitive through either port, the
drive becomes ready for normal operations within 20 seconds (excluding the error recovery procedure).
If the drive receives a START STOP UNIT command with the START bit and IMMED bit equal to 1 and does
not receive a NOTIFY (ENABLE SPINUP) primitive within 5 seconds, the drive fails the START STOP UNIT
command.
The START STOP UNIT command may be used to command the drive to stop the spindle. Stop time is 20 sec-
onds (maximum) from removal of DC power. SCSI stop time is 20 seconds. There is no power control switch
on the drive.
Содержание Savvio 10K
Страница 6: ...iv Savvio 10K 5 SAS Product Manual Rev D...
Страница 8: ......
Страница 36: ...28 Savvio 10K 5 SAS Product Manual Rev D Figure 2 Current profiles for 600GB models...
Страница 37: ...Savvio 10K 5 SAS Product Manual Rev D 29 Figure 3 Current profiles for 450GB models...
Страница 85: ...Savvio 10K 5 SAS Product Manual Rev D 77 W warranty 19 Z zero latency read 66 zone bit recording ZBR 7...
Страница 86: ...78 Savvio 10K 5 SAS Product Manual Rev D...
Страница 87: ......