Seagate Nytro  2.5” x 7mm SSD Product Manual, Rev. A 

7

 

Scope

www.seagate.com

1.6

Out of Band Management (SMBus)

The provides sub-system management data to the host over the SMBus interface at 0x6A

.

Table 5  Out of Band Management (SMBus) Protocol 

Command

Code

Offset

(byte)

Description

0

00

Length of Status: 

Indicates number of additional bytes to read before encountering PEC. This value should always 

be 6 (06h) in implementations of this version of the spec.

01

Status Flags (SFLGS): 

This field indicates the status of the NVM subsystem.

SMBus Arbitration

 – Bit 7 is set ‘1’ after a SMBus block read is completed all the way to the stop bit without bus 

contention and cleared to ‘0’ if a SMBus Send Byte FFh is received on this SMBus slave address.

Drive Not Ready

 – Bit 6 is set to ‘1’ when the subsystem cannot process NVMe management commands, and the rest of 

the transmission may be invalid. If cleared to ‘0’, then the NVM subsystem is fully powered and ready to respond to man-
agement commands. This logic level intentionally identifies and prioritizes powered up and ready drives over their pow-
ered off neighbors on the same SMBus segment.

Drive Functional

 – Bit 5 is set to ‘1’ to indicate an NVM subsystem is functional. If cleared to ‘0’, then there is an 

unrecoverable failure in the NVM subsystem and the rest of the transmission may be invalid.

Reset Not Required 

- Bit 4 is set to ‘1’ to indicate the NVM subsystem does not need a reset to resume normal 

operation. If cleared to ‘0’ then the NVM subsystem has experienced an error that prevents continued normal 

operation. A controller reset is required to resume normal operation.

Port 0 PCIe Link Active

 - Bit 3 is set to ‘1’ to indicate the first port’s PCIe link is up (i.e., the Data Link Control and 

Management State Machine is in the DL_Active state). If cleared to ‘0’, then the PCIe link is down.

Port 1 PCIe Link Active

 - Bit 2 is set to ‘1’ to indicate the second port’s PCIe link is up. If cleared to ‘0’, then the second 

port’s PCIe link is down or not present.

Bits 1-0 shall be set to ‘1’.

02

SMART Warnings: 

This field shall contain the Critical Warning field (byte 0) of the NVMe SMART / Health Information 

log. Each bit in this field shall be inverted from the NVMe definition (i.e., the management interface shall indicate a 

‘0’ value while the corresponding bit is ‘1’ in the log page). See the NVMe specification for bit definitions.

If there are multiple controllers in the NVM subsystem, the management endpoint shall combine the Critical Warning 
field from every controller such that a bit in this field is:
Cleared to ‘0’ if any controller in the subsystem indicates a critical warning for that corresponding bit.
Set to ‘1’ if all controllers in the NVM subsystem do not indicate a critical warning for the corresponding bit.

03

Composite Temperature (CTemp): 

This field indicates the current temperature in degrees Celsius. If a temperature 

value is reported, it should be the same temperature as the Composite Temperature from the SMART log of hottest con-
troller in the NVM subsystem. The reported temperature range is vendor specific, and shall not exceed the 

range -60 to +127°C. The 8 bit format of the data is shown below.

This field should not report a temperature when that is older than 5 seconds. If recent data is not available, the 

NVMe management endpoint should indicate a value of 80h for this field.

   Value                   Description

   00h-7Eh              Temperature is measured in degrees Celsius (0 to 126C)
   7Fh                       127C or higher
   80h                       No temperature data or temperature data is more the 5 seconds old.
   81h                       Temperature sensor failure
   82h-C3h              Reserved
   C4                         Temperature is -60C or lower
   C5-FFh                 Temperature measured in degrees Celsius is represented in twos complement (-1 to -59C)

04

Percentage Drive Life Used (PDLU):

 Contains a vendor specific estimate of the percentage of NVM subsystem NVM life 

used based on the actual usage and the manufacturer’s prediction of NVM life. If an NVM subsystem has multiple con-
trollers the highest value is returned. A value of 100 indicates that the estimated endurance of the NVM in the NVM sub-
system has been consumed, but may not indicate an NVM subsystem failure. The value is allowed to exceed 100. 
Percentages greater than 254 shall be represented as 255. This value should be updated once per power-on hour and 
equal the Percentage Used value in the NVMe SMART Health Log Page.

06 : 05

Reserved: 

Shall be set to 0000h.

07

PEC: 

An 8 bit CRC calculated over the slave address, command code, second slave address and returned data. 

Algorithm is in SMBus Specifications.

Содержание Nytro 5000

Страница 1: ...100810196 Rev A January 2018 Seagate Nytro 5000 PCIe Gen 3 x4 NVMe 2 5 x 7mm Product Manual...

Страница 2: ...ing to drive capacity one gigabyte or GB equals one billion bytes and one terabyte or TB equals one trillion bytes Your computer s operating system may use a different standard of measurement and repo...

Страница 3: ...Supported 16 3 3 Log Page Support 17 3 4 SMART Attributes 18 4 0 Standards and Reference Documents 20 4 1 Regulatory Model Numbers 20 4 2 Standards 20 4 3 Agency and Safety Certifications 20 4 3 1 Sa...

Страница 4: ...able services include Presales Technical support Global Support Services telephone numbers business hours Authorized Service Centers For information regarding Warranty Support visit http www seagate c...

Страница 5: ...upercapacitor Learn cycle 9 0W See Section 1 4 and Section 1 5 for details Shock Operating Non Operating 1500G 0 5ms Gs Vibration Operating 3 08 GRMS 7 800Hz 16 3 GRMS 20 2000Hz Certification CE BSMI...

Страница 6: ...times Typical response times are measured under nominal conditions of temperature and voltage as measured on a representative sample of drives Measurements Measurements are performed on the drive aft...

Страница 7: ...3 W Here is more information on Power NVMe Autonomous Power States are not supported Typical power measurements are based on an average of drives tested under nominal conditions Maximum power is defi...

Страница 8: ...this field shall be inverted from the NVMe definition i e the management interface shall indicate a 0 value while the corresponding bit is 1 in the log page See the NVMe specification for bit definit...

Страница 9: ...slave address and returned data Algorithm is in SMBus Specifications 32 255 32 Vendor Specific This data structure shall not exceed the maximum read length of 255 specified in the SMBus version 3 spe...

Страница 10: ...the defined non operating limits See Table 8 Temperature and Humidity You can extend storage to 1 year packaged or unpackaged under optimal environmental conditions 40 C 40 relative humidity non cond...

Страница 11: ...on Reliability Data Mean Time Between Failures MTBF 2 million hours Data Retention 3 months 40 C Non recoverable Read Errors per bits read 1 per 10E16 NOTE Here is more information on Reliability MTBF...

Страница 12: ...st data that can be written by product when subjected to a specified workload at a specified operating and storage temperature over the specified product life For the specific workload to achieve this...

Страница 13: ...tion dimensions 2 5 models NOTE These dimensions conform to the Small Form Factor Standard documented in SFF 8200 and SFF 8639 The latest revisions may be found at www sffcommittee org 2 2 Bottom Cove...

Страница 14: ...nnector refer to www pcisig com website and the latest PCI Express Electromechanical specification SAS SATA SATA Express 1 st Port S7 S1 7 Pins SAS SA S S S PCI Sideband E6 E1 6 Pins Power SATA Expres...

Страница 15: ...0 S9 NU Not Used E6 RSVD Reserved Seagate Internal S10 NU Not Used P1 NU Not Used S11 GND Ground P2 NU Not Used S12 NU Not Used P3 CLKREQ Clock Request S13 NU Not Used P4 IfDet Interface Detect drive...

Страница 16: ...PETp3 Transmitter differential pair Lane 3 Positive E18 PETn3 Transmitter differential pair Lane 3 Negative E19 GND Ground E20 PERn3 Receiver differential pair Lane 3 Negative E21 PERp3 Receiver diffe...

Страница 17: ...Management Yes 03h O LBA Range Type No 04h M Temperature Threshold Yes 05h M Time limited Error Recovery Yes 06h O Volatile Write Cache No 07h M Number of Queues Yes 08h M Interrupt Coalescing Yes 09...

Страница 18: ...h M Set Features Yes 0Ah M Get Features Yes 0Ch M Async Event Request Yes 0Dh O Namespace Management No 10h M Firmware Commit Yes 11h M Firmware Image Download Yes 15h O Namespace Attachment No 80h O...

Страница 19: ...ed 100 A value of 100 indicates that the estimated endurance of the device has been consumed but may not indicate a device fail ure The value is allowed to exceed 100 Per centages greater than 254 sha...

Страница 20: ...8 16 Power On Hours Contains the number of power on hours This does not include time that the controller was powered and in a low power state condition 144 16 Unsafe Shutdowns Contains the number of u...

Страница 21: ...drive is capable of meeting the Class B limits of the FCC Rules and Regulations of the Canadian Department of Communications when properly packaged however it is the user s responsibility to assure t...

Страница 22: ...C compliance and provide CE marking for the system level products For compliance with the RoHS Recast Directive 2011 65 EU RoHS 2 see Section 4 4 1 on page 23 4 3 6 Australian RCM Compliance Mark If t...

Страница 23: ...ns Commission verification or certification of the device is required Seagate has tested this device in enclosures as described above to ensure that the total assembly enclosure disk drive motherboard...

Страница 24: ...phthalate DEHP Benzyl butyl phthalate BBP Dibutyl phthalate DBP and Diisobutyl phthalate DIBP in electrical and electronic equipment EEE 4 4 1 2 Substances of Very High Concern SVHC The European Union...

Страница 25: ...years in accordance with the Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products SJT 11364 2014 Part Name Hazardous Substances Pb Hg Cd Cr 6 PBB PBDE PCBA Cha...

Страница 26: ...e requirements in Section 5 of CNS 15663 effective January 1 2018 This product is Taiwan RoHS compliant The following table meets the Section 5 Marking of presence requirements Table 22 Taiwan Restric...

Страница 27: ...anical specification revision 3 0 NVMe Non Volatile Memory Express specification 1 2a PCIe CEM PCI Express Card Electromechanical specification revision 1 1 www pcisig com www nvmexpress org Trusted C...

Страница 28: ...ited States 408 658 1000 ASIA PACIFIC Seagate Singapore International Headquarters Pte Ltd 7000 Ang Mo Kio Avenue 5 Singapore 569877 65 6485 3888 EUROPE MIDDLE EAST AND AFRICA Seagate Technology SAS 1...

Отзывы: