5.2.6.2.4

Log page entries

When the drive begins DST, it creates a new entry in the Self-test Results Log page. The new entry is created by inserting a 
new self-test parameter block at the beginning of the self-test results log parameter section of the log page. Existing data will 
be moved to make room for the new parameter block. The drive reports 20 parameter blocks in the log page. If there are 
more than 20 parameter blocks, the least recent parameter block will be deleted. The new parameter block will be initialized 
as follows:

1.

The Function Code field is set to the same value as sent in the DST command

2.

The Self-Test Results Value field is set to Fh

3.

The drive will store the log page to non-volatile memory

After a self-test is complete or has been aborted, the drive updates the Self-Test Results Value field in its Self-Test Results 
Log page in non-volatile memory. The host may use Log Sense to read the results from up to the last 20 self-tests performed 
by the drive. The self-test results value is a 4-bit field that reports the results of the test. If the field is set to zero, the drive 
passed with no errors detected by the DST. If the field is not set to zero, the test failed for the reason reported in the field.

The drive will report the failure condition and LBA (if applicable) in the Self-test Results Log parameter. The Sense key, ASC, 
ASCQ, and FRU are used to report the failure condition.

5.2.6.2.5

Abort

There are several ways to abort a diagnostic. You can use a SCSI Bus Reset or a Bus Device Reset message to abort the 
diagnostic.

You can abort a DST executing in background mode by using the abort code in the DST Function Code field. This will cause 
a 01 (self-test aborted by the application client) code to appear in the self-test results values log. All other abort mechanisms 
will be reported as a 02 (self-test routine was interrupted by a reset condition).

5.2.7

Product warranty

Beginning on the date of shipment to the customer and continuing for the period specified in your purchase contract, 
Seagate warrants that each product (including components and subassemblies) that fails to function properly under normal 
use due to defect in materials or workmanship or due to nonconformance to the applicable specifications will be repaired or 
replaced, at Seagate’s option and at no charge to the customer, if returned by customer at customer’s expense to Seagate’s 
designated facility in accordance with Seagate’s warranty procedure. Seagate will pay for transporting the repair or 
replacement item to the customer. For more detailed warranty information, refer to the standard terms and conditions of 
purchase for Seagate products on your purchase documentation.

The remaining warranty for a particular drive can be determined by calling Seagate Customer Service at 1-800-468-3472. 
You can also determine remaining warranty using the Seagate web site (www.seagate.com). The drive serial number is 
required to determine remaining warranty information.

Shipping

When transporting or shipping a drive, use only a Seagate-approved container. Keep your original box. Seagate approved 
containers are easily identified by the Seagate Approved Package label. Shipping a drive in a non-approved container voids 
the drive warranty.

Seagate repair centers may refuse receipt of components improperly packaged or obviously damaged in transit. Contact 
your authorized Seagate distributor to purchase additional boxes. Seagate recommends shipping by an air-ride carrier 
experienced in handling computer equipment.

Product repair and return information

Seagate customer service centers are the only facilities authorized to service Seagate drives. Seagate does not sanction 
any third-party repair facilities. Any unauthorized repair or tampering with the factory seal voids the warranty.

Содержание Cheetah 100516226

Страница 1: ...tah 15K 7 SAS 100516226 Rev F December 2012 Standard models ST3600057SS ST3450857SS ST3300657SS Self Encrypting Drive models ST3600957SS ST3450757SS ST3300557SS SED FIPS 140 2 models ST3600857SS ST345...

Страница 2: ...877 PUB TEK1 877 782 8351 to request permission When referring to drive capacity one gigabyte or GB equals one billion bytes and one terabyte or TB equals one trillion bytes Your computer s operating...

Страница 3: ...EEK TIME 8 4 2 1 Access time 8 4 2 2 Format command execution time minutes 8 4 2 3 General performance characteristics 9 4 3 START STOP TIME 9 4 4 PREFETCH MULTI SEGMENTED CACHE CONTROL 9 4 5 CACHE OP...

Страница 4: ...3 Default password 31 8 3 RANDOM NUMBER GENERATOR RNG 31 8 4 DRIVE LOCKING 32 8 5 DATA BANDS 32 8 6 CRYPTOGRAPHIC ERASE 32 8 7 AUTHENTICATED FIRMWARE DOWNLOAD 32 8 8 POWER REQUIREMENTS 32 8 9 SUPPORTE...

Страница 5: ...11 4 2 Physical characteristics 50 11 4 3 Connector requirements 50 11 4 4 Electrical description 50 11 4 5 Pin descriptions 50 11 4 6 SAS transmitters and receivers 51 11 4 7 Power 51 11 5 SIGNAL CHA...

Страница 6: ...s business hours Authorized Service Centers For information regarding Warranty Support visit http www seagate com support warranty and returns For information regarding data recovery services visit ht...

Страница 7: ...l Disk Encryption FDE models before a differentiation between drive based encryption and other forms of encryption was necessary Note The Self Encrypting Drive models indicated on the cover of this pr...

Страница 8: ...meeting the Class B limits of the FCC Rules and Regulations of the Canadian Department of Communications when properly packaged however it is the user s responsibility to assure that the drive meets t...

Страница 9: ...ial content declarations for all parts and materials for the disk drives documented in this publication Current supplier declarations include disclosure of the inclusion of any RoHS regulated substanc...

Страница 10: ...ontinue to leverage your existing investment in SCSI while gaining a 3Gb s serial data transfer rate Cheetah 15K 7 SAS SED models have provisions for Security of Data at Rest based on the standards de...

Страница 11: ...own mounting Dynamic spindle brake 16 Mbyte data buffer Drive Self Test Background Media Scan Power Save Cheetah 15K 7 SAS SED models have the following additional features Automatic data encryption d...

Страница 12: ...f LBAs in the Number of Blocks field changes the total drive capacity to the value in the Number of Blocks field A value greater than the maximum number of LBAs is rounded down to the maximum capacity...

Страница 13: ...and formatting 4 2 SEEK TIME See Section 11 4 1 SAS physical interface on page 47 and the SAS Interface Manual part number 100293071 for additional timing details 4 2 1 Access time NOT INCLUDING CONTR...

Страница 14: ...ing a START STOP UNIT command with the START bit equal to 1 the drive waits for a NOTIFY ENABLE SPINUP primitive After receiving a NOTIFY ENABLE SPINUP primitive through either port the drive becomes...

Страница 15: ...ntrol in the SAS Interface Manual The following is a simplified description of the prefetch cache operation Case A read command is received and all of the requested logical blocks are already in the c...

Страница 16: ...nd after the data has been transferred into the cache but before the data has been written to the medium If an error occurs while writing the data to the medium and Good status has already been return...

Страница 17: ...red Unrecoverable Data Errors resulting from the same cause are treated as 1 error for that block 5 1 3 Seek errors A seek error is defined as a failure of the drive to position the heads to the addre...

Страница 18: ...d during the hot connect disconnect operation Discharge the static electricity from the drive carrier prior to inserting it into the system Caution The drive motor must come to a complete stop prior t...

Страница 19: ...interval and failure counters are reset and the process starts over Predictive failures S M A R T signals predictive failures when the drive is performing unacceptably for a period of time The firmwar...

Страница 20: ...l block address LBA of the drive The short test is time restricted and limited in length it does not scan the entire media surface but does some fundamental tests and scans portions of the media If DS...

Страница 21: ...010b for the extended test in bytes 1 bits 5 6 and 7 5 2 6 2 3 Short and extended tests DST has two testing options 1 short 2 extended These testing options are described in the following two subsect...

Страница 22: ...log All other abort mechanisms will be reported as a 02 self test routine was interrupted by a reset condition 5 2 7 Product warranty Beginning on the date of shipment to the customer and continuing...

Страница 23: ...V supply Table 3 600 GB DC power requirements NOTES 3 GBIT MODE 6 GBIT MODE AMPS AMPS AMPS AMPS Voltage 5V 12V 2 5V 12V 2 Regulation 5 5 5 2 5 5 2 Avg idle current 1 7 0 37 0 81 0 38 0 81 Maximum star...

Страница 24: ...ting current random read Typical DC 1 6 1 0 45 1 01 0 47 1 02 Maximum DC 3 1 0 48 1 08 0 51 1 06 Maximum DC peak 3 1 28 2 90 1 30 2 84 Peak operating current random write Typical DC 1 6 1 0 52 0 90 0...

Страница 25: ...econd for 450GB and 300GB models Current and power specified at nominal voltages 7 During idle the drive heads are relocated every 60 seconds to a random location within the band from three quarters t...

Страница 26: ...rm up 5 No terminator power 6 2 1 Conducted noise immunity Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 10 MHz Maximum allowed noise values given...

Страница 27: ...CHEETAH 15K 7 SAS PRODUCT MANUAL REV F 22 Figure 2 Typical 450GB current profiles Figure 3 Typical 300GB current profiles...

Страница 28: ...To calculate BTUs per hour multiply watts by 3 4123 Figure 4 ST3600057SS DC current and power vs input output operations per second 450GB model Typical power dissipation under idle conditions in 6Gb...

Страница 29: ...zed Failure Rate AFR is 122 F 50 C The maximum allowable HDA case temperature is 60 C Occasional excursions of HDA case temperatures above 122 F 50 C or below 41 F 5 C may occur without impact to the...

Страница 30: ...ues below assume that no condensation on the drive occurs a Operating 5 to 95 non condensing relative humidity with a maximum gradient of 20 per hour b Non operating 5 to 95 non condensing relative hu...

Страница 31: ...may promote degraded operational performance during the abnormal shock period Specified operational performance will continue when normal operating shock levels resume Shock may be applied in the X Y...

Страница 32: ...r Z axis b Operating abnormal Equipment as installed for normal operation shall not incur physical damage while subjected to periodic vibration not exceeding 15 minutes of duration at major resonant f...

Страница 33: ...ld films used in Seagate products are especially sensitive to the presence of sulfide chloride and nitrate contaminants Sulfur is found to be the most damaging In addition electronic components should...

Страница 34: ...0 36 014 146 99 MAX 5 787 MAX 131 17 5 164 85 60 3 370 41 15 1 620 2X 29 21 2X 1 150 1 45 057 3 17 125 20 14 793 50 80 2 000 101 60 25 4 000 010 2X 100 13 2X 3 942 98 42 3 875 20 68 814 33 40 1 315 0...

Страница 35: ...ve their modules tested National Voluntary Laboratory Accreditation Program NVLAP accredited laboratories perform cryptographic module compliance conformance testing Seagate Enterprise SED The SED dri...

Страница 36: ...n engine A unique data encryption key is used for each of the drive s possible16 data bands see Section 8 5 8 2 CONTROLLED ACCESS The drive has two security partitions SPs called the Admin SP and the...

Страница 37: ...ndaries 8 6 CRYPTOGRAPHIC ERASE A significant feature of SEDs is the ability to perform a cryptographic erase This involves the host telling the drive to change the data encryption key for a particula...

Страница 38: ...the drive if programmed to do so performs error recovery procedures to attempt to recover the data The error recovery procedures used depend on the options previously set in the Error Recovery Parame...

Страница 39: ...d it restarts on each command Therefore each command s total recovery time is subject to the recovery time limit Note A recovery time limit of 0 will use the drive s default value of FF FF Minimum rec...

Страница 40: ...been verified the drive proceeds with the normal write command If the LBAs have not been verified by BMS Pre Scan will convert the write to a write verify to certify that the data was properly writte...

Страница 41: ...t logical block size 10 1 DRIVE ORIENTATION The drive may be mounted in any orientation All drive performance characterizations however have been done with the drive in horizontal disks level and vert...

Страница 42: ...int when a known force F is applied to the fourth point 10 4 GROUNDING Signal ground PCBA and HDA ground are connected together in the drive and cannot be separated by the user The equipment in which...

Страница 43: ...s a unique SAS address The two ports have the capability of independent port clocking e g both ports can run at 6Gbit sec or the first port can run at 6Gbit sec while the second port runs at 3Gbit sec...

Страница 44: ...evice Behavior page C3h Y Firmware Numbers page C0h Y Implemented Operating Def page 81h Y Jumper Settings page C2h Y Supported Vital Product Data page 00h Y Unit Serial Number page 80h Y Lock unlock...

Страница 45: ...id disk Drive Geometry page 04h Y Unit Attention page 00h Y Verify Error Recovery page 07h Y Xor Control page 10h N Mode Sense 10 same pages as Mode Sense 1Ah 5Ah Y Prefetch 34h N Read 08h Y Read Buff...

Страница 46: ...Equal 31h N Search Data High 30h N Search Data Low 32h N Seek 0Bh Y Seek Extended 2Bh Y Send Diagnostics 1Dh Y Supported Diagnostics pages 00h Y Translate page 40h Y Set Limits 33h N Start Unit Stop...

Страница 47: ...es list that are not changeable by the Mode Select command get their values from default values storage When power is applied to the drive it takes saved values from the media and stores them as curre...

Страница 48: ...all zeros In byte 02 hex value FF equates to the binary pattern 11111111 If there is a zero in any bit position in the field it means that bit is not changeable Since all of the bits in byte 02 are on...

Страница 49: ...00 00 00 00 00 88 aa 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 10 29 0e 00 50 00 c5 00 00 68 64 aa 50 06 05 b0 00 29 2d d4 06 00 00 00 00 00 00 00 88 aa 00 00 00 00 00 00 00 00 00 00 00 0...

Страница 50: ...4b 65 50 06 05 b0 00 29 28 55 07 00 00 00 00 00 00 00 88 aa 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 10 29 0e 00 50 00 c5 00 00 15 4b 66 50 06 05 b0 00 29 28 54 06 00 00 00 00 00 00 00 8...

Страница 51: ...0 00 80 00 00 00 01 00 00 00 00 00 00 00 88 aa 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00 14 2a 0e 00 50 00 c5 00 00 5f 66 d6 50 00 00 00 80 00 00 01 03 00 00 00 00 00 00 00 88 aa 00 00 00...

Страница 52: ...face Manual Figure 12 Physical interface Table 11 Miscellaneous features Supported Feature or condition N Automatic contingent allegiance N Asynchronous event notification N Synchronized locked spindl...

Страница 53: ...1 27 6X 1 27 14X 15 875 0 35MIN 15 875 33 43 0 05 B 4 90 0 08 0 84 0 05 22X 0 15 B P15 P1 S7 S1 SEE Detail1 0 30 0 05 4X 4 00 0 08 0 15 D 0 30 0 05 2X 41 13 0 15 B B C C A A 0 20 B 42 73 REF C OF DATU...

Страница 54: ...5X 0 40 0 05 X 45 3X CORING ALLOWED IN THIS AREA 2 25 0 05 4 85 0 05 0 10 B E S14 S8 4 40 0 15 SEE Detail 2 3 90 0 15 SECTION A A SECTION C C A 0 35 0 05 45 R0 30 0 08 C 1 95 0 08 0 08 0 05 1 23 0 05...

Страница 55: ...n provides a pin out of the SAS device and a description of the functions provided by the pins Table 13 SAS pin descriptions PIN SIGNAL NAME SIGNAL TYPE PIN SIGNAL NAME SIGNAL TYPE S1 Port A Ground P1...

Страница 56: ...d by the system to reduce inrush current to the drive during hot plugging 11 5 SIGNAL CHARACTERISTICS This section describes the electrical signal characteristics of the drive s input and output signa...

Страница 57: ...Forward Equalizer FFE optimized to provide balanced receive margins over a range of channels bounded by the best and worst case channels as defined by the relevant ANSI standard 11 7 ADDITIONAL INFORM...

Страница 58: ...0 caching write data 11 Canadian Department of Communications 3 capacity unformatted 8 CBC 31 check condition status 47 chemical pollutants 28 Cipher Block Chaining 31 class B limit 3 clear ACA functi...

Страница 59: ...Read After Write 35 inquiry data 42 installation 36 interface commands supported 39 error rate 12 errors 12 illustrated 47 physical 47 requirements 38 intermediate condition met good status 47 interm...

Страница 60: ...nted cache control 9 preventive maintenance 12 protection of data at rest 31 Q queue tagging 47 R radio interference regulations 3 Random number generator 31 RCD bit 10 read error rates 12 33 read wri...

Страница 61: ...em chassis 37 T task management functions 38 Abort task set 38 Clear ACA 38 Clear task set 38 terminate task 38 task management response codes 38 Function complete 00 38 Function not supported 05 38 F...

Страница 62: ...ted States 408 658 1000 ASIA PACIFIC Seagate Singapore International Headquarters Pte Ltd 7000 Ang Mo Kio Avenue 5 Singapore 569877 65 6485 3888 EUROPE MIDDLE EAST AND AFRICA Seagate Technology SAS 16...

Отзывы: