24
Barracuda 1 and 2 Product Manual, Rev. C
To confirm that required cooling for the Barracuda electronics and HDA is
provided, place the drive in its final mechanical configuration, perform
random write/read operations, and after the temperatures stabilize, measure
the case temperature of the components listed below.
Air-flow cooling
ST11950N and ST12550N single-ended drives
MTBF
500k hours
Card
Component
Reference
case temperature (°C)
TYFX
Transmitter
U5
57
TYFX
Writer
U35
66
TYFX
LSI
U4
60
TYFX
VIC2
U20
59
TYFX
1021
U55
57
HDA housing
Figure 11
48
The air-flow pattern with which the temperature guidelines above were
generated is shown in Figure 6 (opposite direction). Local average air
velocity was 0.61 msec (120 lfpm) and inlet air temperature to the drive was
30°C (86°F).
The maximum allowable HDA case temperature is 60°C.
Figure 7. TYFX temperature measurement locations
U5
U35
U4
U20
U55
Содержание Barracuda ST11950N
Страница 1: ...Barracuda 1 and 2 Disc Drive ST11950N ND ST11950W WD ST12550N ND ST12550W WD Product Manual Volume 1...
Страница 2: ......
Страница 3: ...Barracuda 1 and 2 Disc Drive ST11950N ND ST11950W WD ST12550N ND ST12550W WD Product Manual Volume 1...
Страница 6: ......
Страница 12: ...2 Barracuda 1 and 2 Product Manual Rev C...
Страница 14: ...4 Barracuda 1 and 2 Product Manual Rev C...
Страница 20: ...10 Barracuda 1 and 2 Product Manual Rev C...
Страница 30: ...20 Barracuda 1 and 2 Product Manual Rev C...
Страница 40: ...30 Barracuda 1 and 2 Product Manual Rev C...
Страница 52: ...42 Barracuda 1 and 2 Product Manual Rev C...
Страница 54: ...44 Barracuda 1 and 2 Product Manual Rev C...
Страница 88: ...78 Barracuda 1 and 2 Product Manual Rev C...
Страница 93: ...Barracuda 1 and 2 Product Manual Rev C 83...