84
Barracuda 36ES Product Manual, Rev. H
Notes.
[1]
See the
SCSI Interface Product Manual,
part number 75789509, Timing examples section.
[2]
Maximum SCSI asynchronous interface transfer rate is given in Section 4.2.3 of this manual.
[3]
Synchronous Transfer Period is determined by negotiations between an Initiator and a Drive. The Drive is
capable of setting periods as given in Section 9.5. See also the Synchronous data transfer section and the
Extended messages section of the
SCSI Interface Product Manual,
for a description of synchronous data
transfer operation.
9.11
Drive activity LED
The following table provides drive activity LED status.
Data In Byte Transfer (parameter)
T24
4.5-12
0.04
µ
s
Data Out Byte Transfer (parameter)
T25
4.5-13
0.04
µ
s
Next Data In Byte Access (parameter)
T26
4.5-12
0.12
µ
s
Next Data Out Byte Access (parameter)
T27
4.5-13
0.12
µ
s
Data In Byte Transfer (media) [2]
T28
4.5-12
0.04
µ
s
Data Out Byte Transfer (media) [2]
T29
4.5-13
0.04
µ
s
Next Data In Byte access (media [2]
T30
4.5-12
0.12
µ
s
Next Data Out Byte access (media [2]
T31
4.5-13
0.12
µ
s
MSG IN Byte Transfer
T32
4.5-5,7,8,14,15
0.04
µ
s
MSG OUT Byte Transfer
T33
4.5-2
0.04
µ
s
STATUS Byte Transfer
T34
4.5-5,8,15
0.04
µ
s
Synchronous Data Transfer Characteristics:
Request Signal Transfer Period [3]
–
–
various (800 ns max)
Table 21:
Drive activity LED status
Spindle status
Command status
LED status
Spinning up with DC power applied
N/A
On until spinup is complete
Spun down
Start Unit
On while processing the command
Powered down by removal of DC power N/A
Off due to absence of power
Spun up
Stop Unit
On while processing the command
Spun down
No command activity
Off
Spun down
Write/Read Buffer
On while processing the command
Spun down
SCSI Bus Reset
On while processing the reset
Spun down
Test Unit Ready
On while processing the command
Spun up
No command activity
Off
Spun up
Write/Read
On while processing the command
Spun up
SCSI Bus Reset
On while processing the reset
Spun up
Test Unit Ready
On while processing the command
Spun up
Format with Immediate option on On while the command is initially processed
Spun up
Format without Immediate
LED toggles on/off on each cylinder boundary
Table 20:
Disc drive SCSI timing (Continued)
Description
Waveform
symbol [1]
Waveform
table [1]
Typical timing
Содержание Barracuda 36ES ST318417N
Страница 1: ...Barracuda 36ES Family ST336737LW LC ST318437LW LC ST318417N W Product Manual Volume 1...
Страница 2: ......
Страница 3: ...Barracuda 36ES Family ST336737LW LC ST318437LW LC ST318417N W Product Manual Volume 1...
Страница 6: ......
Страница 10: ......
Страница 12: ...2 Barracuda 36ES Product Manual Rev H...
Страница 30: ...20 Barracuda 36ES Product Manual Rev H...
Страница 44: ...34 Barracuda 36ES Product Manual Rev H...
Страница 56: ...46 Barracuda 36ES Product Manual Rev H...
Страница 98: ...88 Barracuda 36ES Product Manual Rev H...
Страница 105: ......