background image

Barracuda 36ES Product Manual, Rev. H

15

5.2.6

Hot plugging Barracuda 36ES disc drives

The ANSI SPI-3 (T10/1302D) document defines the physical requirements for removal and insertion of SCSI
devices on the SCSI bus. Four cases are addressed. The cases are differentiated by the state of the SCSI bus
when the removal or insertion occurs.

Case 1 - All bus devices powered off during removal or insertion

Case 2 - RST signal asserted continuously during removal or insertion

Case 3 - Current I/O processes not allowed during insertion or removal

Case 4 - Current I/O process allowed during insertion or removal, except on the device being changed

Seagate Barracuda 36ES disc drives support all four hot plugging cases. Provision shall be made by the sys-
tem such that a device being inserted makes power and ground connections prior to the connection of any
device signal contact to the bus. A device being removed shall maintain power and ground connections after
the disconnection of any device signal contact from the bus (see T10/1302D SPI-3 Annex C).

It is the responsibility of the systems integrator to assure that no hazards from temperature, energy, voltage, or
ESD potential are presented during the hot connect/disconnect operation.

All I/O processes for the SCSI device being inserted or removed shall be quiescent. All SCSI devices on the
bus shall have receivers that conform to the SPI-3 standard.

If the device being hot plugged uses single-ended (SE) drivers and the bus is currently operating in low voltage
differential (LVD) mode, then all I/O processes for all devices on the bus must be completed, and the bus qui-
esced, before attempting to hot plug. Following the insertion of the newly installed device, the SCSI host
adapter must issue a Bus Reset, followed by a synchronous transfer negotiation. Failure to perform the SCSI
Bus Reset could result in erroneous bus operations.

The SCSI bus termination and termination power source shall be external to the device being inserted or
removed.

End users should not mix devices with high voltage differential (HVD) drivers and receivers and devices with
SE, LVD, or multimode drivers and receivers on the same SCSI bus since the common mode voltages in the
HVD environment may not be controlled to safe levels for SE and LVD devices (see ANSI SPI-3).

The disc drive spindle must come to a complete stop prior to completely removing the drive from the cabinet
chassis. Use of the Stop Spindle command or partial withdrawal of the drive, enough to be disconnected from
the power source, prior to removal are methods for insuring that this requirement is met. During drive insertion,
care should be taken to avoid exceeding the limits stated in Section 6.4.4, "Shock and vibration" in this manual.

5.2.7

S.M.A.R.T.

S.M.A.R.T. is an acronym for Self-Monitoring Analysis and Reporting Technology. This technology is intended
to recognize conditions that indicate a drive failure and is designed to provide sufficient warning of a failure to
allow data back-up before an actual failure occurs. 

Note.

The firmware will monitor specific attributes for degradation over time but cannot predict instantaneous
drive failures.

Each attribute has been selected to monitor a specific set of failure conditions in the operating performance of
the drive, and the thresholds are optimized to minimize “false” and “failed” predictions.

Controlling S.M.A.R.T.

The operating mode of S.M.A.R.T. is controlled by the DEXCPT bit and the PERF bit of the “Informational
Exceptions Control Mode Page” (1Ch). The DEXCPT bit is used to enable or disable the S.M.A.R.T. process.
Setting the DEXCPT bit will disable all S.M.A.R.T. functions. When enabled, S.M.A.R.T. will collect on-line data
as the drive performs normal read/write operations. When the PERF bit is set, the drive is considered to be in
“On-line Mode Only” and will not perform off-line functions.

Содержание Barracuda 36ES ST318417N

Страница 1: ...Barracuda 36ES Family ST336737LW LC ST318437LW LC ST318417N W Product Manual Volume 1...

Страница 2: ......

Страница 3: ...Barracuda 36ES Family ST336737LW LC ST318437LW LC ST318417N W Product Manual Volume 1...

Страница 4: ...Barracuda SeaFAX SeaFONE SeaBOARD and SeaTDD are either registered trademarks or trademarks of Seagate Technology LLC Other product names are registered trademarks or trademarks of their owners Seaga...

Страница 5: ...ual Volume 2 part number 75789509 Revision Date Writer Engineer Sheets Affected Rev A 12 11 2000 K Schweiss B Reynolds 1 1 v thru ix 1 94 Rev B 02 22 2001 K Schweiss B Reynolds 4 55 57 59 and 80 Rev C...

Страница 6: ......

Страница 7: ...3 Generalized performance characteristics 9 4 3 Start stop time 10 4 4 Prefetch multi segmented cache control 10 4 5 Cache operation 10 4 5 1 Caching write data 11 4 5 2 Prefetch operation 12 5 0 Reli...

Страница 8: ...48 9 3 1 Inquiry Vital Product data 52 9 3 2 Mode Sense data 54 9 4 SCSI bus conditions and miscellaneous features supported 61 9 5 Synchronous data transfer 63 9 5 1 Synchronous data transfer period...

Страница 9: ...nfiguration dimensions 33 Figure 15 J6 jumper header for LW and LC models 38 Figure 16 J6 jumper header for N model 39 Figure 17 J5 jumper header on LW and W models only 40 Figure 18 J2 option select...

Страница 10: ......

Страница 11: ...his manual The SCSI Interface Product Manual part num ber 75789509 describes general SCSI interface characteristics of this and other families of Seagate drives The SCSI Interface Product Manual refer...

Страница 12: ...2 Barracuda 36ES Product Manual Rev H...

Страница 13: ...properly packaged However it is the user s responsibility to assure that the drive meets the appropriate EMI requirements in their system Shielded I O cables may be required if the enclosure does not...

Страница 14: ...Technology International Manufacturing start date 02 2001 Manufacturer nationality Singapore Taiwanese BSMI If this model has two Chinese words meaning EMC certification followed by an eight digit ide...

Страница 15: ...utomatic features that relieve the host from the necessity of knowing the physical characteristics of the targets logical block addressing is used The head and disc assembly HDA is sealed at the facto...

Страница 16: ...data embedded on each surface to elimi nate mechanical transducer adjustments and related reliability concerns A high performance actuator assembly with a low inertia balanced patented straight arm de...

Страница 17: ...servo design Self diagnostics performed when power is applied to the drive 1 1 Interleave Zoned bit recording ZBR Vertical horizontal or top down mounting Dynamic spindle brake 2 048 kbyte data buffe...

Страница 18: ...of blocks field A value greater than the maximum number of LBAs is rounded down to the maximum capacity 3 7 Factory installed accessories OEM Standard drives are shipped with the Barracuda 36ES Instal...

Страница 19: ...differential LVD interface mode 5 0 to 80 Mbytes sec 5 0 to 160 Mbytes sec ST336737 ST318437 ST318417 Drive capacity 36 954 18 400 18 400 Gbytes formatted rounded off Read write heads 4 2 2 Bytes tra...

Страница 20: ...typically excluding an error recovery procedure The Motor Start Command can also be used to command the drive to stop the spindle see SCSI Interface Product Manual part number 75789509 There is no po...

Страница 21: ...e configurations which includes their use in the prefetch operation if enabled even when cache operation is disabled see Section 4 5 2 The number of segments may be selected using the Mode Select comm...

Страница 22: ...that is prefetched replaces data already in some buffer segment s the host can limit the amount of prefetch data to optimize system perfor mance The max prefetch field bytes 8 and 9 limits the amount...

Страница 23: ...recovery procedures without operator interven tion 5 1 2 Read errors Before determination or measurement of read error rates The data that is to be used for measurement of read error rates must be ve...

Страница 24: ...drive shall have accumulated at least nine months of operation Data shall be calculated on a rolling average base for a minimum period of six months MTBF is based on the following assumptions 8 760 po...

Страница 25: ...I Bus Reset could result in erroneous bus operations The SCSI bus termination and termination power source shall be external to the device being inserted or removed End users should not mix devices wi...

Страница 26: ...s are logged and compared to the num ber of total operations for a given attribute The interval defines the number of operations over which to mea sure the rate The counter that keeps track of the cur...

Страница 27: ...d Recovered errors will not be reported as diagnostic failures 5 2 8 2 Implementation This section provides all of the information necessary to implement the DST function on this drive 5 2 8 2 1 State...

Страница 28: ...Value field in its Self Test Results Log page in non volatile memory The host may use Log Sense to read the results from up to the last 20 self tests performed by the drive The self test results valu...

Страница 29: ...to purchase additional boxes Seagate recommends shipping by an air ride carrier experienced in handling computer equipment Product repair and return information Seagate customer service centers are th...

Страница 30: ...20 Barracuda 36ES Product Manual Rev H...

Страница 31: ...Motor Start Option is enabled and the drive has not yet received a Start Motor command 5 See Section 6 2 1 Conducted Noise Immunity Specified voltage tolerance is inclusive of ripple noise and transi...

Страница 32: ...s against inadvertent writing during power up and down Daisy chain operation requires that power be maintained on the SCSI bus terminator to ensure proper termination of the peripheral I O cables To a...

Страница 33: ...le 0 0 2 4 6 8 10 12 14 16 0 0 0 5 1 0 1 5 2 0 2 5 3 0 A Seconds AC Envelope 12 Volt Current during spindle start Typical Amperes Nominal average DC curve T0 T3 T1 T2 T5 T4 0 0 2 4 6 8 10 12 14 16 0 0...

Страница 34: ...ent profile 0 0 2 4 6 8 10 12 14 16 0 0 0 5 1 0 1 5 2 0 2 5 3 0 A Seconds AC Envelope 12 Volt Current during spindle start Typical Amperes Nominal average DC curve T0 T3 T1 T2 T5 T4 0 0 2 4 6 8 10 12...

Страница 35: ...m read operations refer to the following I O rate curve see Figure 7 Locate the typical I O rate for a drive in your system on the horizontal axis and read the corresponding 5 volt current 12 volt cur...

Страница 36: ...9 Locate the typical I O rate for a drive in your system on the horizontal axis and read the cor responding 5 volt current 12 volt current and total watts on the vertical axis To calculate BTUs per ho...

Страница 37: ...temperatures see note 1 The maximum allowable continuous or sustained temperature for rated MTBF is 113 F 45 C To confirm that the required cooling for the drive is provided place the drive in its fi...

Страница 38: ...k not exceeding 63 Gs at a maximum duration of 2 msec half sinewave Shock may be applied in the X Y or Z axis b Non operating The limits of non operating shock shall apply to all conditions of handlin...

Страница 39: ...ged in single or multipacks with a gross weight of 20 pounds 8 95 kg or less by Seagate for general freight shipment shall withstand a drop test from 48 inches 1 070 mm against a concrete floor or equ...

Страница 40: ...assumes system recovery routines are available c Non operating The limits of non operating vibration shall apply to all conditions of handling and transportation This includes both isolated drives an...

Страница 41: ...iguration dimensions See Section 8 3 Drive mounting Figure 12 LW and W mounting configuration dimensions Height 1 000 in 25 4 mm Width 4 000 in 101 6 mm Depth 5 75 in 146 05 mm Weight 1 2 pounds ST336...

Страница 42: ...32 Barracuda 36ES Product Manual Rev H Figure 13 LC mounting configuration dimensions 0 Notes 1 2 3 4 5 6 7 8 8 9 88 8 8 8 8 8 8 8 8 Dimension Table 3 2 5 6 4 7...

Страница 43: ...Barracuda 36ES Product Manual Rev H 33 Figure 14 N mounting configuration dimensions Notes 0 1 2 3 4 5 6 7 8 8 9 88 8 8 8 8 8 8 8 8 Dimension Table 2 1 4 6 3 7...

Страница 44: ...34 Barracuda 36ES Product Manual Rev H...

Страница 45: ...such as are required in video applications For addi tional information on this refer to the Error Recovery Page table in the SCSI Interface Product Manual which describes the Mode Select Mode Sense Er...

Страница 46: ...default value of FF FF Minimum recovery time limit is achieved by setting the Recovery Time Limit field to 00 01 7 3 SCSI systems errors Information on the reporting of operational errors or faults ac...

Страница 47: ...desired operation prior to power on If jumpers are changed after power has been applied recycle the drive power to make the new settings effective Installation instructions are provided by host syste...

Страница 48: ...rs retain cover 11 9 7 5 3 1 Drive Activity LED 4 6 Dashed area is optional host circuitry external to the drive connected to host supplied optional usage plug Do not connect anything to pins 13 20 5V...

Страница 49: ...SCSI ID 4 SCSI ID 5 SCSI ID 6 SCSI ID 7 L E D R E S R E S Reserved Pin 1 Shipped with cover installed Do not install jumpers retain cover 11 9 7 5 3 1 Drive Activity LED Ground 4 6 Dashed area is opti...

Страница 50: ...4P Ground Host 4 Alternate Usage Plug Pins 1 3 5 and 7 are optional connections to switching circuits in host equipment to establish drive ID Remote Switches For ID selection use jumpers as shown or...

Страница 51: ...elay Motor Start Enable Remote Motor Start Write Protect Parity Disable Term Power to SCSI Bus S E D S M E W P P D R E S R E S T P 1 Jumper Positions Force single ended bus mode applies to LW model on...

Страница 52: ...J5 connector signals conform to SFF 8009 Revision 2 0 Unitized Connector for Cabled Drives signal assignments for auxiliary connectors 2 These signals are also on 80 pin J1 I O connector See tables 1...

Страница 53: ...wer connected drive 1 starts after 12 second delay drive 2 starts after 24 second delay etc On On Drive spindle starts when Start Unit command received from host Delayed start feature is overridden an...

Страница 54: ...d using the tempera ture measurement guidelines described in Section 6 4 1 Forced air flow may be required to keep temperatures at or below the specified case temperatures in which case the drive shou...

Страница 55: ...to 5 25 inch adapter frame verify with Seagate Tech nology that the drive can meet the shock and vibration specifications given herein while mounted in such an adapter frame Adapter frames that are av...

Страница 56: ...46 Barracuda 36ES Product Manual Rev H...

Страница 57: ...sages supported by the SCSI 2 and SCSI 3 modes of the Barracuda 36ES family drives Table 4 SCSI messages supported by Barracuda 36ES family drives Message name Message code Supported by SCSI 2 3 Abort...

Страница 58: ...18h N Copy and verify 3Ah N Format unit 1 04h Y Block Format N Bytes from index Y Physical sector format Y DPRY bit supported N DCRT bit supported Y STPF bit supported Y IP bit supported Y DSP bit su...

Страница 59: ...ense 10 same pages as Mode Sense 1Ah 5Ah Y Prefetch 34h N Read 08h Y Read buffer modes 0 2 3 Ah and Bh supported 3Ch Y Read capacity 25h Y Read defect data 10 37h Y Read defect data 12 B7h Y Read exte...

Страница 60: ...diagnostics pages 00h Y Translate page 40h Y DST logical unit self test diagnostics Y Set limits 33h N Start unit stop unit spindle ceases rotating 1Ch 1Bh Y Synchronize cache 35h Y Test unit ready 00...

Страница 61: ...reflect model of drive The table above shows hex values for Model ST336737LC Values for all models are listed below ST336737LC 33 33 36 37 33 37 4C 43 ST336737LW 33 33 36 37 33 37 4C 57 ST318437LC 33...

Страница 62: ...length 14 4 23 Product serial number Y Implemented operating definition page 81h 0 Peripheral qualifier peripheral device type 1 Page code number 81 2 Reserved 00 3 Page length 03 4 SAVIMP 0 current o...

Страница 63: ...pages Descriptions of their usage are not available at this time Jumper settings page C2h 0 Peripheral qualifier peripheral device type Y 1 Page code number C2 2 Reserved 00 3 Page length 02 4 SCSI ID...

Страница 64: ...hese are hex numbers representing the changeable values for mode page 01 Note that bytes 04 05 06 and 07 are not changeable because those fields are all zeros If some changeable code had a hex value E...

Страница 65: ...4 00 00 02 5E 02 00 00 01 00 39 00 57 40 00 00 00 03 CHG 83 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 04 SAV 84 16 00 74 9B 04 00 00 00 00 00 00 00 00 00 00 00 00 00 00 1C 2...

Страница 66: ...ns set to the firmware default condition one for drives with the LW interface Drives man ufactured with all other interfaces LC set the Saved value of the PM bit set to the Server mode zero 3 When the...

Страница 67: ...4 00 00 02 5E 02 00 00 01 00 39 00 57 40 00 00 00 03 CHG 83 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 04 SAV 84 16 00 74 9B 02 00 00 00 00 00 00 00 00 00 00 00 00 00 00 1C 2...

Страница 68: ...ns set to the firmware default condition one for drives with the LW interface Drives man ufactured with all other interfaces LC set the Saved value of the PM bit set to the Server mode zero 3 When the...

Страница 69: ...4 00 00 02 5E 02 00 00 01 00 39 00 57 40 00 00 00 03 CHG 83 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 04 SAV 84 16 00 74 9B 02 00 00 00 00 00 00 00 00 00 00 00 00 00 00 1C 2...

Страница 70: ...ns set to the firmware default condition one for drives with the LW interface Drives man ufactured with all other interfaces LC set the Saved value of the PM bit set to the Server mode zero 3 When the...

Страница 71: ...er from SCSI I O cable pin 26 Y Active termination enabled N and W models only N Adaptive caching Y Adaptive read look ahead Y Arbitrating system Y ASYNC burst rate of 5 Mbytes sec single ended Y Asyn...

Страница 72: ...me per cylinder N Sparing scheme per track N Sparing scheme per volume Y Sparing scheme per zone Y Strict bit support Y Sustained transfer rate of 3 Mbytes sec single ended N Sync spindles rotational...

Страница 73: ...s 22 and 23 show the locations of the DC power connector SCSI interface connector drive select head ers and option select headers Details of the physical electrical and logical characteristics are giv...

Страница 74: ...a 36ES Product Manual Rev H Figure 21 N model drive physical interface 50 pin SCSI I O connector Pin 1 SCSI I O Connector Pin 1 DC Power Connector J6 J1 Pin 1P 2P 3P 4P Power 12V 12V ret 5V ret 5V J1...

Страница 75: ...Barracuda 36ES Product Manual Rev H 65 Figure 22 LW and W model drive physical interface 68 pin J1 SCSI I O connector Figure 23 LC model drive physical interface 80 pin J1 SCSI I O connector Pin Power...

Страница 76: ...s Some type of external termination circuits must be provided for these drives by the end user or designers of the equipment into which the drives will be integrated See Standard X3T10 1302D sections...

Страница 77: ...connectors Part numbers for the different type connectors that mate with the various Barracuda 36ES I O connectors are given in the sections following 9 6 4 1 Mating connectors for N model drives N m...

Страница 78: ...can be on the end with the terminator the host having no terminator 4 Total interface cable length must not exceed that specified in ANSI document X3T10 1302D including host adapter initiator The cab...

Страница 79: ...ctor is keyed by means of its shape see Figure 26 Figure 26 Nonshielded 68 pin SCSI device connector used on W and LW drives Amp Model 786096 7 Female 68 pin panel mount Amp Model 786090 7 Female 68 p...

Страница 80: ...interface cable length must not exceed that specified in ANSI document X3T10 1302D including host adapter initiator The cable length restriction limits the total number of devices allowed 5 SCSI ID7 h...

Страница 81: ...become too long for safe power transmission to the drive Daisy chain 80 conductor cables should especially not be allowed since the power carrying conductors on the 80 conductor interface were not in...

Страница 82: ...72 Barracuda 36ES Product Manual Rev H Figure 28 Nonshielded 80 pin SCSI SCA 2 connector used on LC drives Front View End View Top View Back View...

Страница 83: ...onnector contact number 13 Cable conductor number 12 Connector contact number 13 Signal name 1 GND 1 1 2 2 DB0 GND 3 3 4 4 DB1 GND 5 5 6 6 DB2 GND 7 7 8 8 DB3 GND 9 9 10 10 DB4 GND 11 11 12 12 DB5 GND...

Страница 84: ...9 10 39 DBP1 GND 6 11 12 40 DB0 GND 7 13 14 41 DB1 GND 8 15 16 42 DB2 GND 9 17 18 43 DB3 GND 10 19 20 44 DB4 GND 11 21 22 45 DB5 GND 12 23 24 46 DB6 GND 13 25 26 47 DB7 GND 14 27 28 48 DBP GND 15 29 3...

Страница 85: ...12 40 DB0 DB1 7 13 14 41 DB1 DB2 8 15 16 42 DB2 DB3 9 17 18 43 DB3 DB4 10 19 20 44 DB4 DB5 11 21 22 45 DB5 DB6 12 23 24 46 DB6 DB7 13 25 26 47 DB7 DBP 14 27 28 48 DBP Ground 15 29 30 49 Ground DIFFSN...

Страница 86: ...NC 10 6 46 DIFFSNS 8 DB11 7 47 GND DB10 8 48 GND DB9 9 49 GND DB8 10 50 GND I O 11 51 GND REQ 12 52 GND C D 13 53 GND SEL 14 54 GND MSG 15 55 GND RST 16 56 GND ACK 17 57 GND BSY 18 58 GND ATN 19 59 GN...

Страница 87: ...6 46 DIFFSNS 8 DB11 7 47 DB11 DB10 8 48 DB10 DB9 9 49 DB9 DB8 10 50 DB8 I O 11 51 I O REQ 12 52 REQ C D 13 53 C D SEL 14 54 SEL MSG 15 55 MSG RST 16 56 RST ACK 17 57 ACK BSY 18 58 BSY ATN 19 59 ATN DB...

Страница 88: ...may be used to implement equivalent contact assignments 13 Connector contacts are on 0 100 inch 2 54 mm centers 9 7 Electrical description Barracuda 36ES LW and LC model drives are multimode devices T...

Страница 89: ...t characteristics shall additionally conform to EIA RS 485 Figure 29 LVD output signals Input characteristics Each signal Vs received by LVD interface receiver circuits shall have the following input...

Страница 90: ...e terminator power is an active circuit which has an input source voltage selected by jumper plug TP See Figure 19 Applies to N and W models 5 Interface signal levels and logical sense at the drive I...

Страница 91: ...neral cable characteristics A characteristic impedance of 100 ohm 10 is recommended for unshielded flat or twisted pair ribbon cable However most available cables have a somewhat lower characteristic...

Страница 92: ...ween the SCSI I O cable and the drive I O connector or on the end of a short I O cable stub extending past the last cable connector LC drives are designed to be plugged into a backpanel connector with...

Страница 93: ...ndent Reselect Identify MSG to Data media T16 4 5 11 Command Dependent Data to Status T17 4 5 15 Command Dependent Status to Command Complete MSG T18 4 5 5 8 15 0 98 s Command Complete MSG to Bus Free...

Страница 94: ...2 T31 4 5 13 0 12 s MSG IN Byte Transfer T32 4 5 5 7 8 14 15 0 04 s MSG OUT Byte Transfer T33 4 5 2 0 04 s STATUS Byte Transfer T34 4 5 5 8 15 0 04 s Synchronous Data Transfer Characteristics Request...

Страница 95: ...5 toll free 9 A M to 7 P M eastern time Monday through Friday Tape Purchases US customers can purchase Seagate data cartridges tape supplies accessories and select Seagate tape drive products 24 hours...

Страница 96: ...87 Warranty Service Call Center Toll free Direct dial FAX Internet USA 1 800 468 3472 1 405 936 1456 1 405 936 1462 Mexico and Latin America 1 405 936 1456 1 405 936 1464 Canada Memofix 1 800 636 6349...

Страница 97: ...ervices For Asia Pacific presales and technical support dial the toll free number for your specific country The Asia Pacific toll free numbers are available from 6 00 A M to 10 45 A M and 12 00 P M to...

Страница 98: ...88 Barracuda 36ES Product Manual Rev H...

Страница 99: ...ulkhead connector 66 bus device reset message 54 bytes per sector 50 bytes surface 9 bytes track 9 C cabinet cooling 44 cable 63 cable length 80 cache 10 11 12 cache buffer 7 cache miss 11 cache mode...

Страница 100: ...mounting 31 45 constraints 13 drive orientation 44 drive power 37 drive primary defects list 35 drive SCSI timing 83 drive select header 63 drive spindle 43 drive transfer 11 drive volume 37 drive wa...

Страница 101: ...gical 10 logical block 10 11 12 logical characteristics 63 logical segment mode select page 08h 10 low level format 37 low voltage differential LVD drivers and receivers 7 LVD 79 LVD interface receive...

Страница 102: ...ower supply voltage 13 power carrying conductor 71 power on 37 78 power on operating hours 14 power on reset 54 power up 22 43 power up hours 14 prefetch 10 11 12 prefetch read look ahead 10 12 prefet...

Страница 103: ...single ended drive 80 single ended SCSI driver 80 single ended SCSI receiver 80 site installation 14 software interleave 12 source voltage 80 spare part 14 spindle 22 spindle startup 43 standard day 2...

Страница 104: ...te error 13 V vibration 28 30 vital product data 52 volatile memory 54 voltage 10 21 W warranty 7 18 wet bulb temperature 27 wide SCSI Ultra160 interface 5 WP jumper 43 wrap around 11 write caching 11...

Страница 105: ......

Страница 106: ...Seagate Technology LLC 920 Disc Drive Scotts Valley California 95066 4544 USA Publication Number 75789521 Rev H Printed in USA...

Отзывы: