Barracuda 18FC Product Manual, Rev. B
17
Seagate repair centers may refuse receipt of components improperly packaged or obviously damaged in tran-
sit. Contact your authorized Seagate distributor to purchase additional boxes. Seagate recommends shipping
by an air-ride carrier experienced in handling computer equipment.
Product repair and return information
Seagate customer service centers are the only facilities authorized to service Seagate drives. Seagate does
not sanction any third-party repair facilities. Any unauthorized repair or tampering with the factory seal voids
the warranty.
5.3.8
Hot plugging the drive
Inserting and removing the drive on the FC-AL will interrupt loop operation. The interruption occurs when the
receiver of the next device in the loop must synchronize to a different input signal. FC error detection mecha-
nisms, character sync, running disparity, word sync, and CRC are able to detect any error. Recovery is initiated
based on the type of error.
The disc drive defaults to the FC-AL Monitoring state, Pass-through state, when it is powered-on by switching
the power or hot plugged. The control line to an optional port bypass circuit (external to the drive), defaults to
the Enable Bypass state. If the bypass circuit is present, the next device in the loop will continue to receive the
output of the previous device to the newly inserted device. If the bypass circuit is not present, loop operation is
temporarily disrupted until the next device starts receiving the output from the newly inserted device and
regains synchronization to the new input.
The Pass-through state is disabled while the drive performs self test of the FC interface. The control line for an
external port bypass circuit remains in the Enable Bypass state while self test is running. If the bypass circuit is
present, loop operation may continue. If the bypass circuit is not present, loop operation will be halted while the
self test of the FC interface runs.
When the self test completes successfully, the control line to the bypass circuit is disabled and the drive enters
the FC-AL Initializing state. The receiver on the next device in the loop must synchronize to output of the newly
inserted drive.
If the self-test fails, the control line to the bypass circuit remains in the Enable Bypass state.
Note.
It is the responsibility of the systems integrator to assure that no temperature, energy, voltage hazard,
or ESD potential hazard is presented during the hot connect/disconnect operation. Discharge the static
electricity from the drive carrier prior to inserting it into the system.
Caution.
The drive motor must come to a complete stop prior to changing the plane of operation. This time is
required to insure data integrity.
Содержание Barracuda 18FC ST118273FC
Страница 1: ... Barracuda 18FC Disc Drive ST118273FC Product Manual Volume 1 ...
Страница 2: ......
Страница 3: ... Barracuda 18FC Disc Drive ST118273FC Product Manual Volume 1 ...
Страница 6: ......
Страница 10: ......
Страница 12: ......
Страница 18: ......
Страница 28: ......
Страница 34: ......
Страница 42: ......
Страница 64: ......
Страница 68: ......
Страница 75: ......