Cheetah 15K.5 SCSI Product Manual, Rev. D
13
4.3
Start/stop time
After DC power at nominal voltage has been applied, the drive becomes ready within 20 seconds if the Motor
Start Option is disabled (i.e., the motor starts as soon as the power has been applied). If a recoverable error
condition is detected during the start sequence, the drive executes a recovery procedure which may cause the
time to become ready to exceed 20 seconds. During spin up to ready time the drive responds to some com-
mands over the SCSI interface in less than 3 seconds after application of power. Stop time is 30 seconds from
removal of DC power.
If the Motor Start Option is enabled, the internal controller accepts the commands listed in the SCSI Interface
Product Manual less than 3 seconds after DC power has been applied. After the Motor Start Command has
been received the drive becomes ready for normal operations within 20 seconds typically (excluding an error
recovery procedure). The Motor Start Command can also be used to command the drive to stop the spindle
(see the SCSI Commands Reference Manual).
There is no power control switch on the drive.
4.4
Prefetch/multi-segmented cache control
The drive provides prefetch (read look-ahead) and multi-segmented cache control algorithms that in many
cases can enhance system performance. “Cache” as used herein refers to the drive buffer storage space when
it is used in cache operations. To select prefetch and cache features the host sends the Mode Select command
with the proper values in the applicable bytes in Mode Page 08h (see the SCSI Interface Product Manual).
Prefetch and cache operation are independent features from the standpoint that each is enabled and disabled
independently via the Mode Select command. However, in actual operation the prefetch feature overlaps
cache operation somewhat as is noted in Section 4.5.1 and Section 4.5.2.
All default cache and prefetch Mode parameter values (Mode Page 08h) for standard OEM versions of this
drive family are given in Table 10.
4.5
Cache operation
Note.
Refer to the SCSI Interface Manual for more detail concerning the cache bits.
Of the 16 Mbytes physical buffer space in the drive, approximately 13,000 kbytes can be used as a cache. The
buffer is divided into logical segments from which data is read and to which data is written.
The drive keeps track of the logical block addresses of the data stored in each segment of the buffer. If the
cache is enabled (see RCD bit in the SCSI Interface Manual ), data requested by the host with a read com-
mand is retrieved from the buffer, if possible, before any disc access is initiated. If cache operation is not
enabled, the buffer is still used, but only as circular buffer segments during disc medium read operations (dis-
regarding Prefetch operation for the moment). That is, the drive does not check in the buffer segments for the
requested read data, but goes directly to the medium to retrieve it. The retrieved data merely passes through
some buffer segment on the way to the host. All data transfers to the host are in accordance with buffer-full
ratio rules. See the explanation provided with the information about Mode Page 02h (disconnect/reconnect
control) in the SCSI Interface Manual.
The following is a simplified description of the prefetch/cache operation:
Case A—read command is received and all of the requested logical blocks are already in the cache:
1.
Drive transfers the requested logical blocks to the initiator.
Case B—A Read command requests data, and at least one requested logical block is not in any segment of
the cache:
1.
The drive fetches the requested logical blocks from the disc and transfers them into a segment, and then
from there to the host in accordance with the Mode Select Disconnect/Reconnect parameters, page 02h.
2.
If the prefetch feature is enabled, refer to section 4.5.2 for operation from this point.
Содержание 15K.5 - Cheetah - Hard Drive
Страница 1: ...Cheetah 15K 5 SCSI ST3300655LW ST3300655LC ST3146855LW ST3146855LC ST373455LW ST373455LC Users Guide...
Страница 6: ......
Страница 8: ...2 Cheetah 15K 5 SCSI Product Manual Rev D...
Страница 12: ...6 Cheetah 15K 5 SCSI Product Manual Rev D...
Страница 42: ...36 Cheetah 15K 5 SCSI Product Manual Rev D...
Страница 92: ......
Страница 93: ......