32
inserts fixed in the case, we recommend not tightening with excessive
force to reduce the risk of stripping. The recommended torque is 12 Ncm.
The O-ring seal on the battery compartment is radial, so excessive closing
force on the compartment screws is not necessary.
NOTE
Do not dispose of used batteries in the environment or discard them as ordinary
waste; we recommend using special battery disposal services.
APNEA SERIAL NUMBER
The APNEA serial number is engraved on the back of the case and can also
be viewed on the display in the “INFO” function along with the version of the
firmware installed.
EC CERTIFICATION
APNEA is compliant with CE Regulations.
The EU Declaration of Conformity is available at: www.seacsub.com
CARE AND MAINTENANCE
• Keep your computer clean and dry. Do not expose the computer to chemical
agents, including alcohol.
Use only fresh water to clean your computer, removing all saline deposits.
Leave the computer to dry naturally; do not use jets of hot or cold air. A jet of
pressurized air hitting the pressure sensor could damage it irreparably.
• Do not expose the computer directly to the sun or to sources of heat above
50°C. Store the computer in a cool (5°C - 25°C) and dry place.
• Do not place the computer in a hyperbaric chamber.
The computer is designed for a reading accuracy of +/- 2%. The degree of
accuracy required by the European standards is +/- 3.5%.
European standards require that the unit be checked periodically to monitor the
precision of its depth and time readings.
• The warranty will be forfeited if the computer is opened by an unauthorized
service center.
• The computer is manufactured to withstand use in seawater, but after the dive