12
When the Software Application is launched, a test of the battery under load
is performed. When this happens you may notice the backlighting turn on
temporarily. If the battery voltage under load is less than 2.0V (Minimum
Voltage), the device will remain off or locked, on a screen with the words “
LOW
BAT
”. In some cases you may see a continuing Reset for a few cycles.
If the battery voltage under load is below 1.8V (Start Voltage), the backlighting
may remain on continuously until the computer battery is completely drained. In
this case, the computer will not turn on at all and no text appears on the LCD.
The Battery icon on the display has 2 segments:
Segment 1: Battery Outline ==> Battery lower than Minimum Voltage (do not
dive).
Segment 2: First Bar from the bottom ==> Battery lower than 2.1V (Low level.
The voltage could plummet during a dive in especially cold water).
Theoretical run-time, linked strictly to the quality of the battery installed:
Mode
Theoretical average run-time
(years)
Factory Mode
8.4
Watch
3.0
100 sessions/year
2.9
200 sessions/year
2.7
300 sessions/year
2.1
The data indicated above:
• refer to a new battery of recent manufacture (and therefore not subject to
excessive auto-draining);
• refer to use at 25°C/77°F;
• refer to use that does not entail direct exposure to sunlight;
• do not include consumption by backlighting and audible alarms.