APNEA
31
The step counter function will be terminated automatically and will switch to the
watch screen if not used for 4 hours.
LAYOUT PEDOMETER
REPLACING THE BATTERY
•
WARNING!
Batteries should always be replaced by an authorized SEAC Center,
because this is a delicate operation with a high probability of subsequent
flooding of the computer if performed by inexpert personnel.
SEAC declines all responsibility for problems resulting from changing the
battery.
•
WARNING!
When replacing the CR2450 battery, it's a good idea to also replace the
O-ring of the battery cap with an original SEAC O-ring.
a) Fully unscrew and remove the four screws from the battery compartment
using a PH 00 model Phillips head screwdriver.
b) Insert a small flathead screwdriver into the special opening located on the
bottom of the cap to lift the lid.
c) If needed, again using the small flathead screwdriver, prize up the battery
from its housing and remove it.
d) Insert the new battery, snapping it into its housing and making sure that
the “+” polarity sign is facing outward.
e) Remove the old O-ring from the housing in the metal cover and replace
it with the new one. Make sure that the O-Ring is not damaged, and once
inserted make sure it isn't twisted at any point.
f) Position the cover on the APNEA case, and press it evenly downward. Make
sure that in the area around the screws, the cover is flush with the case.
g) Keep the cover pressed down on the APNEA case while replacing the
three screws. Although the four screws are screwed through four metal