background image

NOTES

 

The electrical installation and the operation logics must comply with current regulations. Keep the power cables (motors, power supply) 
separated from the control cables (push-buttons, photo-eyes, radio, etc.). Separate conduits should be used to prevent noise issues. 

Note: 

Use “cable clips” and/or “duct/box pipes” fitting close to the control panel box so to protect the interconnection cables against pulling 

efforts.

INTENDED USE

 

VERG system has been designed exclusively for the automation of barriers. 

SPARE PARTS

The spare parts orders must be sent to:
     

 SEA S.p.A.  Zona Ind.le, 64020 S.ATTO  Teramo  Italy

SAFETY AND RESPECT FOR THE ENVIRONMENT

 

We recommend not to spoil the environment with product and circuit packing material. 

STORAGE

STORAGE TEMPERATURE

T

min

-30°C

T

max

+60°C

Humidity

min

5% without condensation

Humidity

max

90% without condensation

The product must be handled using suitable means. 

LONG-TERM STOP AND MAINTENANCE

 

The disassembly and/or stop and /or maintenance of the VERG automation system must be carried out by skilled and expert technicians. 

GUARANTEE LIMITS

For the guarantee see the sales conditions on the official SEA price list.

NOTE: THE MANUFACTURER SHALL NOT SHOULDER ANY RESPONSIBILITIES IN CASE OF DAMAGE CAUSED BY 
INAPPROPRIATE, WRONG OR CARELESS USE. 

SEA reserves the right to make all the necessary changes and modifications of the products and / or manuals without giving prior 
notice.

English

Sistemi Elettronici

di Apertura Porte e Cancelli

International registered trademark n. 804888

®

11) Release system

To release operate as follows

-       Turn the protection cap of the release.

Insert the 

and turn it about 180° into 

clockwise direction until the beam is released (Fig. 
12).

-       Open manually the beam.

        
To re-lock operate as follows

-       Turn the 

 into anti-clockwise direction 

(Fig. 13).

-    Extract the key.
-       Re-close the protection cap.

T shaped key 

T shaped key

PERIODICAL MAINTENANCE

All above mentioned operations must be executed exclusively by authorized installers.

Check the functionality of the release

 

Lubricate the bearing of the balance

Check the efficiency of the spring

Check the beam fixing screws and the balance and the casing

Check the integrity of the connexion cables  

Check the efficiency of the batteries (where included)

Check and eventually adjust the value of intervention of the  

anti-crash sensor.

Annually

Annually

Annually

Annually

Annually

Annually

Annually

To the attention of users and technicians 

180°

Fig.12

180°

Fig.13

Release

Lock

19

R
(OPTIONAL)

elease key with extractable cylinder

Release

Cod. 67411465                                                 Rev.00 - 12/2012                                                              

Fig.14

Содержание VERG 24V

Страница 1: ... system is composed of the following elements 1 Adjustable mechanical stop 2 Manual release with key 3 Galvanised steel rocker arm 4 VERG 24V casing cover with lock and DIN key 5 Balancing spring 6 Electronic control unit 7 Foundation plate out of galvanized steel 8 Emergency batteries 2x12V 2Ah 9 24V 2400 rpm electric motor 10 Reduction gear 11 Cataphoresis treated and polyester painted VERG 24V ...

Страница 2: ...Fig 2 Fig 1 Opening on the right Opening on the left 12 230 V 5 50 60 Hz 115 V 5 50 60 Hz 24Vdc 60 W 2400 20 55 C IP55 Yes 60 A Yes E 39 kg USER 1 24V RPM Adjustable mmeter lectronic Cataphoresis treated and polyester painted 128 56 1148 288 203 VERG 230V VERG 115V Note The frequency of use is valid only for the first hour at 20 C room temperature OVERALL DIMENSIONS To guarantee longer life of the...

Страница 3: ...ng nuts and washers Hole for the conduit containing the electrical cables 3 Post anchoring on the foundation plate Place the casing so that the holes on the base match the screws located on the foundation plate Make sure that the conduit for the cables goes through the large hole of the casing base Insert the bracket for anchoring the spring A in case of left hand mounting B in case of right hand ...

Страница 4: ...ing of the spring Anchor the spring on the bracket which has been mounted before S Insert the rod of the spring into the bracket B and insert the nuts D without tightening them OVAL BEAM Length m 3 4 5 Balance position 1 4 1 4 1 4 Spring Ø mm 6 7 5 8 5 Note Strictly follow the opening time to avoid bad working Note The springs and the bracket of anchorage are supplied with the beam Opening time 3 ...

Страница 5: ... Note For 4 and 5 m beams it is recommended to use the fork support or the flexible support English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 Fig 7 15 Cod 67411465 Rev 00 12 2012 ...

Страница 6: ... 8 Beam levelling Note this operation must be carried out only if the beam is not perfectly horizontal closing stage or vertical opening stage at the end of its stroke Release the beam with the special manual release so that it is free to open and close manually Release the screws of the limit switch on unscrewing the nuts on the mechanical stops fig 9 Loosen or tighten the stop screws so that the...

Страница 7: ... mA Battery Ah 9 Battery charger circuit English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 GND GND GND GND PSOL PSOL BAT BAT 28V 28V S S USER24 charge 200mA Solar Panel Batteries GND GND Grey connector CN1 charge 360mA charge 800mA 12V 12V 12V 12V 12 or 16 7 2 800 360 200 Fig 10 17 Cod 67411465 Rev 00 12 2012 ...

Страница 8: ...3 Receiving photocell 4 Key switch 5 Radio receiver 6 Flashing light 7 Push button station 8 Differential switch English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 ACCESSORIES FOR VERG FORK SUPPORT BATTERY KIT PHOTOCELLS KEY SWITCH WARNING LAMP Fig 11 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 2x1 2x1 4x1 3x1 5 3x1 Fig 11 2X1 1xRG58 18 Cod 67411465 Rev 00 12 ...

Страница 9: ...OT SHOULDER ANY RESPONSIBILITIES IN CASE OF DAMAGE CAUSED BY INAPPROPRIATE WRONG OR CARELESS USE SEAreserves the right to make all the necessary changes and modifications of the products and or manuals without giving prior notice English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 11 Release system To release operate as follows Turn the protection c...

Отзывы: