TECHNICAL FEATURES
Supply voltage
Motor power supply
Motor power
Motor speed
Working temperature
Opening/closing time
Protection class
Manual release system
Usage frequency
Anti-crushing device
Holding block
Slowdown
Barrier body treatment
Weight
Electronic equipment
INSTALLATION INSTRUCTIONS
1) Spring position
Thanks to its high flexibility, the barrier you are installing can be closed
on the right-hand or left-hand side of the post, according to your needs.
e.g. if the spring is on the right-hand side, the guard closes on the left
(see Fig. 2).
English
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
Fig.2
Fig.1
Opening on the right
Opening on the left
12
230 V~ ± 5% - 50/60 Hz 115 V~ ± 5% - 50/60 Hz
24Vdc
60 W
2400
-20° + 55°C
IP55
Yes
60%
A
Yes
E
39 kg
USER 1 24V
RPM
Adjustable
mmeter
lectronic
Cataphoresis treated and polyester painted
128
56
1
148
288
203
VERG 230V
VERG 115V
Note
: The frequency of
use is valid only for the
first hour at 20°C room
temperature.
OVERALL DIMENSIONS:
*To guarantee longer life of the barrier, SEA
recommend to adjust the speed giving an extra time
of at least 1 sec from the Max Speed as for this chart.
** SEA grant those performances only for the 1st
hour of operation. After 1 st hours cycles can drop
up to 50%. Cycles are granted only with slowdown
active. Periodically check the balance of the beam.
VERG 2mt 3mt 4mt 5mt
Max Speed* 2-3 sec 3-4 sec 4-5 sec 5-6 sec
Cycles** 60% 50% 45% 35%
BEAMS RECOMMENDED SPEED
Cod. 67411465 Rev.00 - 12/2012