7)   Beam balancing

Release the beam with manual release, so 
that it is free to be opened and closed 
manually (Fig.8).

Place the beam at approx. 45°.

Loosen or tighten the spring stretching nut 
until the spring counterbalances the weight of 
the 45° beam (Fig. 8). The best balancing 
position is obtained when the beam reaches 
the position shown in Fig. 8.

After having obtained the balancing, lock the 
nuts of the spring stretcher with the counter 
nut and re-block the motor.

Should the balancing of the beam not be 
perfect and the   length of the spring stretcher 
(T) be   too long, cut it about half of its length.   

Spring 

 nut

stretching

Anchoring

lock nut

8)   Beam levelling

Note: this operation must be carried out only if 
the beam is not perfectly horizontal (closing 
stage) or vertical (opening stage) at the end of its 
stroke.

Release the beam with the special manual 
release so that it is free to open and close 
manually.

Release the screws of the limit switch on 
unscrewing the nuts on the mechanical stops 
(fig.9).

Loosen or tighten the stop screws so that the 
beam is released in its vertical position 
(opening stage) (Fig. 9) and horizontal position 
(closing stage).

After having executed the levelling lock the 
screws of the limit switch tightening the nuts on 
the mechanical stops and re-lock the beam.

Stop adjustment

screws

Lock nuts

Rocker

arm

English

Sistemi Elettronici

di Apertura Porte e Cancelli

International registered trademark n. 804888

®

4

°

5

T

Fig. 8

Fig.9

16

Cod. 67411465                                                 Rev.00 - 12/2012                                                              

Содержание VERG 24V

Страница 1: ... system is composed of the following elements 1 Adjustable mechanical stop 2 Manual release with key 3 Galvanised steel rocker arm 4 VERG 24V casing cover with lock and DIN key 5 Balancing spring 6 Electronic control unit 7 Foundation plate out of galvanized steel 8 Emergency batteries 2x12V 2Ah 9 24V 2400 rpm electric motor 10 Reduction gear 11 Cataphoresis treated and polyester painted VERG 24V ...

Страница 2: ...Fig 2 Fig 1 Opening on the right Opening on the left 12 230 V 5 50 60 Hz 115 V 5 50 60 Hz 24Vdc 60 W 2400 20 55 C IP55 Yes 60 A Yes E 39 kg USER 1 24V RPM Adjustable mmeter lectronic Cataphoresis treated and polyester painted 128 56 1148 288 203 VERG 230V VERG 115V Note The frequency of use is valid only for the first hour at 20 C room temperature OVERALL DIMENSIONS To guarantee longer life of the...

Страница 3: ...ng nuts and washers Hole for the conduit containing the electrical cables 3 Post anchoring on the foundation plate Place the casing so that the holes on the base match the screws located on the foundation plate Make sure that the conduit for the cables goes through the large hole of the casing base Insert the bracket for anchoring the spring A in case of left hand mounting B in case of right hand ...

Страница 4: ...ing of the spring Anchor the spring on the bracket which has been mounted before S Insert the rod of the spring into the bracket B and insert the nuts D without tightening them OVAL BEAM Length m 3 4 5 Balance position 1 4 1 4 1 4 Spring Ø mm 6 7 5 8 5 Note Strictly follow the opening time to avoid bad working Note The springs and the bracket of anchorage are supplied with the beam Opening time 3 ...

Страница 5: ... Note For 4 and 5 m beams it is recommended to use the fork support or the flexible support English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 Fig 7 15 Cod 67411465 Rev 00 12 2012 ...

Страница 6: ... 8 Beam levelling Note this operation must be carried out only if the beam is not perfectly horizontal closing stage or vertical opening stage at the end of its stroke Release the beam with the special manual release so that it is free to open and close manually Release the screws of the limit switch on unscrewing the nuts on the mechanical stops fig 9 Loosen or tighten the stop screws so that the...

Страница 7: ... mA Battery Ah 9 Battery charger circuit English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 GND GND GND GND PSOL PSOL BAT BAT 28V 28V S S USER24 charge 200mA Solar Panel Batteries GND GND Grey connector CN1 charge 360mA charge 800mA 12V 12V 12V 12V 12 or 16 7 2 800 360 200 Fig 10 17 Cod 67411465 Rev 00 12 2012 ...

Страница 8: ...3 Receiving photocell 4 Key switch 5 Radio receiver 6 Flashing light 7 Push button station 8 Differential switch English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 ACCESSORIES FOR VERG FORK SUPPORT BATTERY KIT PHOTOCELLS KEY SWITCH WARNING LAMP Fig 11 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 2x1 2x1 4x1 3x1 5 3x1 Fig 11 2X1 1xRG58 18 Cod 67411465 Rev 00 12 ...

Страница 9: ...OT SHOULDER ANY RESPONSIBILITIES IN CASE OF DAMAGE CAUSED BY INAPPROPRIATE WRONG OR CARELESS USE SEAreserves the right to make all the necessary changes and modifications of the products and or manuals without giving prior notice English Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 11 Release system To release operate as follows Turn the protection c...

Отзывы:

Похожие инструкции для VERG 24V