SET
DESCRIPTION
DEFAULT NOTE
17
OPENING SPEED M1
30 100
Setting from 30 to 100
75
18
CLOSING SPEED M1
30 100
Setting from 30 to 100
75
19
OPENING SPEED M2
30 100
Setting from 30 to 100
75
20
CLOSING SPEED M2
30 100
Setting from 30 to 100
75
21
SLOWDOWN SPEED IN
OPENING M1
30 100
Setting from 30 to 100
30
22
SLOWDOWN SPEED IN
CLOSING M1
30 100
Setting from 30 to 100
30
23
SLOWDOWN SPEED IN
OPENING M2
30 100
Setting from 30 to 100
30
24
SLOWDOWN SPEED IN
CLOSING M2
30 100
Setting from 30 to 100
30
25
LEARNING SPEED
30 100
Setting from 30 to 100
50
26
LEAF DELAY IN
OPENING
Off 6
Setting from OFF to 6 seconds
3
27
LEAF DELAY IN
CLOSING
Off 20
Setting from OFF to 20 seconds
3
28
OPENING TORQ 1
10 100
Opening torque Motor 1: by increasing the torque, more
strenght will be required to execute the inversion in case
of obstacle
70
29
CLOSING TORQ 1
10 100
Closing torque Motor 1: by increasing the torque, more
strenght will be required to execute the inversion in case
of obstacle
70
30
OPENING TORQ 2
10 100
Opening torque Motor 2: By increasing the torque, more
strenght will be required to execute the inversion in case
of obstacle
70
31
CLOSING TORQ 2
10 100
Closing torque Motor 2: By increasing the torque, more
strenght will be required to execute the inversion in case
of obstacle
70
32
ENCODER
On
ON = Encoder enabled
OFF = Encoder disabled - shows working times learnt
Off
32
ENCODER
Potentiometer
Enables the reading of the potentiometer with LE card
Off
51
I.PAR.M1
- - - - - - - -
52
I.AP.M1
From the value learned
to ± 100 pulses
53
I.CH.M1
From the value learned
to ± 100 pulses
54
I.PAR.M2
- - - - - - - -
55
I.AP.M2
From the value learned
to ± 100 pulses
56
I.CH.M2
From the value learned
to ± 100 pulses
Reports the current position of the potentiometer on the leaf of Motor
1. This parameter is useful for seeing if the potentiometer is read
correctly
Reports the impulses stored by the control unit when the leaf of Motor
1 is fully open
Reports the impulses stored by the control unit when the leaf of Motor
1 is fully close
Reports the current position of the potentiometer on the leaf of Motor
2. This parameter is useful for seeing if the potentiometer is read
correctly
Reports the impulses stored by the control unit when the leaf of Motor
2 is fully open
Reports the impulses stored by the control unit when the leaf of Motor
2 is fully close
SPECIAL MENU
PRESS AT THE SAME TIME FOR 5 SECONDS TO ENTER OR TO EXIT THE SPECIAL MENU
USER 2 24V DG R1B "ALL - IN" SPECIAL MENU FUNCTIONS TABLE
For entering into the special menu move on one of the menu and press the UP and DOWN buttons at the same time for 5 seconds
For exiting the special menu press END or move on one of the menu and press the UP and DOWN at the same time for 5 seconds
SP MENU
UP DOWN
55
Содержание USER 2 24V DG R1B ALL-IN
Страница 38: ...Notes ...