12) Standard installation
In Fig.18 you find the necessary wiring for the barrier installation.
The two numbers placed next to the electric cables show their quantity and section.
Legend:
1) Electronic control unit
2) Photocell (receiver)
3) Photocell (transmitter)
4) Key switch
5) Radio receiver
6) Warning light
7) Push button board
8) Differential switch
Fig.18
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
2x1
2x1
2x1 1XRG58
4x1
3x1,5
3x1
PHOTOCELLS
SKIRT (ONLY ON SIDE BEAM)
COUNTER PLATE
FOR FORK SUPPORT
KEY SWITCH
WARNING LAMP
13) Accessories
for
STORM
FIXED FORK
SUPPORT
ADJUSTABLE
FORK SUPPORT
FEXLIBLE SUPPORT