background image

STORM 24V

®

International registered trademark n. 2.777.971

web site: www.sea-usa.com

e-mail: [email protected]

SEA USA Inc. 

10850 N.W.  21st unit 160 DORAL MIAMI 

Florida (FL) 33172

Phone:++1-305.594.1151  Fax: ++1-305.594.7325

Toll Free: 800.689.4716

Rev. 00 - 11.2010

Code 67411125

Содержание STORM 24V

Страница 1: ...red trademark n 2 777 971 web site www sea usa com e mail sales sea usa com SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 Rev 00 11 2010 Code 67411125 ...

Страница 2: ...tions from the control panel s to the operator s must be made in a waterproof junction box The system requires a separate power supply circuit Check that the main power supply circuit breakers are separated intended solely for this equipment and rated for 15AMPS Visually check that the circuit breakers are in OFF position and mark the circuit breakers USED prior to installation Permanent wiring mu...

Страница 3: ... stopping the gate properly all the pinch points and potential entrapment areas are reduced Check and test all reversing devices The installer should instruct user on the operator system s proper operation They should together review the basic functions of the reversing devices and how to periodically test them Reversing devices include one or more of the followings reversing loops photocells reve...

Страница 4: ...consists of The cataphoresis and epoxy treated dust painted steel sheet casing protects all mechanical and electric devices from atmospheric agents On request it is also possible to receive the casing in stainless steel The balancing spring is delivered according to the beam length inside the beam kit See spring tab GATE 1 electronic control unit for 230 version and USER 1 24V for 24V version adva...

Страница 5: ...n the desired side it is possible to invert it following the instructions Fig 1 Note The frequency of use is valid only for the first hour at 20 C room temperature Rectangular beam Barrier Length 16 40 feet 19 68 22 96 24 60 D Spring 0 41 in 0 43 0 45 0 49 Fexlible support yes yes yes yes Linear beam Barrier Length D Spring Fexlible support yes yes yes Type of skirt 14 76 feet 18 04 21 32 Barrier ...

Страница 6: ...ig 4 and 5 N B Before executing this operation release the motor reducer as shown in Fig 19 Once exchanged the connecting rod tighten its fixation screw and lubricate with grease Use DIN 51502 KP2 N 20 K 2 K 20 grease Tighten at Max 50 Nm Spring support Spring tensioning bolt Fig 3 Mi 39 n 0 in Min 39 in 0 Fig 6 Fig 4 Fig 5 Connecting rod Connecting rod SEA USA Inc 10850 N W 21st unit 160 DORAL MI...

Страница 7: ...tion plate as in Fig 8 Level the plate with care The plate has got a central hole for electric wiring so before filling the hole with concrete put an elettric wire sheathing on the hole Concrete Fondation plate to be levelled Wire sheathing Clamps 60 Fig 8 15 74 31 49 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 Int...

Страница 8: ...n Tighten the column to the foundation plate screwing the provided nuts and bolts with care Fixing nuts bolts Hole for wire sheathing Fig 9 Fig 10 5 Mounting of the central beam with fork Fig 10 Beam Nuts and bolts for beam fixing SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 International registered trademark n 2 77...

Страница 9: ...g 11 Fig 11 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 International registered trademark n 2 777 971 Storm 24V Rev 00 11 2010 Code 67411125 9 ...

Страница 10: ...eam at 45 Fig 14 After balancing fix the spring adjusting bolt locknut with the bolt and block the motor reducer 9 Barrier power supply Now it is possible to power supply the barrier Place the beam at approx 45 and execute the balancing with the nuts of Fig 14 To obtain a correct balancing the beam must be on 45 and the operator must be unlocked SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Flor...

Страница 11: ...rews so that the beam stays in perfectly vertical position in opening and in perfectly horizontal position in closing Fig 15 After levelling fix the end stroke by tightening the lock nuts on the limit switch and block the actuator Spring tension adjusting bolt Spring bolt locknut 11 Levelling of the central beam with fork First extract the screws B than the screws C Fig 16 Continue as described in...

Страница 12: ... button board 8 Differential switch Fig 18 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 2x1 2x1 2x1 1XRG58 4x1 3x1 5 3x1 PHOTOCELLS SKIRT ONLY ON SIDE BEAM COUNTER PLATE FOR FORK SUPPORT KEY SWITCH WARNING LAMP 13 Accessories for STORM FIXED FORK SUPPORT ADJUSTABLE FORK SUPPORT FEXLIBLE SUPPORT ONLY BEAM SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 To...

Страница 13: ...CE Check the functionality of the release Annually Lubricate all moving parts Annually Check the efficiency of the spring balancing Annually Check the beam fixing screws the balance and the casing Annually Check the integrity of the connexion cables Annually All above mentioned operations must be executed exclusively by authorized installers SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida ...

Страница 14: ...nths warranty from the date of invoice on manufacturing assembling and workmanship defects Electro mechanic motors and electronic control systems 24 months warranty from the date of invoice on manufacturing assembling and workmanship defects Lepus and Full Tank Standard model 60 months warranty from the date of invoice on manufacturing assembling and workmanship defects No warranty will be recogni...

Страница 15: ......

Страница 16: ...w sea usa com e mail sales sea usa com SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 International registered trademark n 2 777 971 ...

Отзывы:

Похожие инструкции для STORM 24V