background image

GENERAL SAFETY INFORMATION 

An  appliance  shall  be  provided  with  an  instruction  manual.  The  instruction  manual  shall  give  instructions  for  the 
installation, operation, and user maintenance of the appliance.
The installation instructions shall specify the need for a grounding-type receptacle for connection to the supply and 
shall stress the importance of proper grounding.
The installation instructions shall inform the installer that permanent wiring is to be employed as required by local 
codes, and instructions for conversion to permanent wiring shall be supplied.

Information shall be supplied with a gate operator for:

a) The required installation and adjustment of all devices and systems to effect the primary and secondary protection 
against entrapment (where included with the operator).
b)  The  intended  connections  for  all  devices  and  systems  to  effect  the  primary  and  secondary  protection  against 
entrapment. The information shall be supplied in the instruction manual, wiring diagrams, separate instructions, or the 
equivalent.

Vehicular gate operators (or systems)

A vehicular gate operator shall be provided with the information in the instruction manual that defines the different 
vehicular gate operator Class categories and give examples of each usage. The manual shall also indicate the use for 
which the particular unit is intended as defined in Glossary, Section 3. The installation instructions for vehicular gate 
operators shall include information on the Types of gate for which the gate operator is intended.

A gate operator shall be provided with the specific instructions describing all user adjustments required for proper 
operation of the gate. Detailed instructions shall be provided regarding user adjustment of any clutch or pressure relief 
adjustments provided. The instructions shall also indicate the need for periodic checking and adjustment by a qualified 
technician of the control mechanism for force, speed, and sensitivity.

Instructions for the installation, adjustment, and wiring of external controls and devices serving as required protection 
against entrapment shall be provided with the operator when such controls are shipped with the operator.

Instructions regarding intended installation of the gate operator shall be supplied as part of the installation instructions 
or as a separate document. The following instructions or the equivalent shall be supplied where applicable:

IMPORTANT INSTALLATION INSTRUCTIONS

a) Install the gate operator only when:

1) The operator is appropriate for the construction of the gate and the usage Class of the gate,
2) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet 

(1.22 m) above the ground to prevent a 2-1/4 inch (57.2 mm) diameter sphere from passing through the openings 
anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position,

3) All exposed pinch points are eliminated or guarded, and
4) Guarding is supplied for exposed rollers.

b) The  operator  is  intended  for  installation  only  on  gates  used  for  vehicles.  Pedestrians  must  be  supplied  with  a 
separate access opening. The partial access opening shall be designed to promote pedestrian usage. Locate the gate 
such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate.

c) The  gate  must  be  installed  in  a  location  so  that  enough  clearance  is  supplied  between  the  gate  and  adjacent 
structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access 
areas.

d) The gate must be properly installed and work freely in both directions prior to the installation of the gate operator. Do 
not over-tighten the operator clutch or pressure relief valve to compensate for a damaged gate.

e) The gate operator controls must be placed so that the user has full view of the gate area when the gate is moving and 
AWAY FROM THE GATE PATH PERIMETER.

f) Controls intended for user activation must be located at least six feet (6’) away from any moving part of the gate and 
where the user is prevented from reaching over, under, around or through the gate to operate the controls. Outdoor or 
easily accessible controls shall have a security feature to prevent unauthorized use.

g) The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of the reset control shall not 
cause the operator to start.

h) A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate where easily visible

International registered trademark n. 2.777.971

Содержание Libra Full Tank

Страница 1: ...N W 21st unit 160 DORAL MIAMI Florida FL 33172 USA Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 web site www sea usa com e mail sales sea usa com REV 11 09 2018 NEW MINI TANK HALF TA...

Страница 2: ...danger 8 Do not allow children to play or stay within the path of the moving gate 9 Keep remote control or any other control devices out of the reach of children in order to avoid possible involuntary...

Страница 3: ...ng intended installation of the gate operator shall be supplied as part of the installation instructions or as a separate document The following instructions or the equivalent shall be supplied where...

Страница 4: ...es on not assessable further risks SEA USA Inc in its relentless aim to improve the products is allowed to make whatsoever adjustment without giving notice This doesn t oblige SEA to up grade the past...

Страница 5: ...to move toward a rigid objact closer than 16 inches 406mm are not required to be provided with a means of entrapment protection B1 and B2 means of entrapment protection MUST be MONITORED HORIZONTAL S...

Страница 6: ...the whole movement of the leaf PRECAUTIONS SEA motors have been created for the automation of gates used by vehicles only Be aware to avoid the crossing of the gate path because it is very dangerous f...

Страница 7: ...FULLTANK high quality hydraulic operator condominium industrial use max leaf length of 23 feet Ideal for CONTINUOUS use Available in 4 models AC up to 5 9 feet with lock in opening and closing for le...

Страница 8: ...E TECHNICAL FEATURES 7 22 feet 23 feet 100 55 Use rate Max leaf length HALF TANK 19 68 feet 5 9 feet HALF TANK HALF TANK LARGE HT LARGE FULL TANK FULL TANK FULL TANK LARGE FULL TANK LARGE MINI TANK 9...

Страница 9: ...ig 11 Release By pass valves Rear attachment Breather screw Front bracket Shaft Cover End cover Shaft FULL TANK Oscillating fork Brass pin short Long front fixation hinge Electric Motor Pump Distribut...

Страница 10: ...tic frame Adjustm ent key By pass valves only for the installe r Aluminium release with key Optional Oil fill in cover Long front fixation hinge Brass pin short Breather screw R o d e n d m o u n t i...

Страница 11: ...Adjustm ent key By pass valves only for the installe r Aluminium release with key Optional Small antivibration plastic frame Brass pin short Long front fixation hinge Breather screw Shaft NEW MINI TAN...

Страница 12: ...ST have separate entrance TYPICAL INSTALLATION Fig 15 Fig 16 inside inside Outside Outside Inward installation Outward installation 1 Operator 2 Mechanical stop 3 Electronic control unit 4 Flashing la...

Страница 13: ...13 inside outside a d b INWARD INSTALLATION c Fig 17...

Страница 14: ...4 9 84 9 84 9 84 9 84 9 84 9 84 9 84 9 96 a inches b inches d max inches Max opening Angle Max stroke inches Stroke for 90 inches 4 92 6 69 2 95 125 14 48 11 61 5 11 6 69 3 14 125 14 64 11 81 5 51 9 2...

Страница 15: ...15 inside outside OUTWARD INSTALLATION a d b c Fig 18...

Страница 16: ...ches Max opening Angle Max stroke inches Stroke for 90 inches 9 84 3 93 100 14 01 13 46 10 03 3 75 95 13 58 13 22 10 43 3 75 95 10 62 3 54 90 12 99 10 82 90 12 79 10 82 90 12 55 9 84 9 84 3 54 3 54 13...

Страница 17: ...the rear oscillating bracket as shown in Fig 19 Attach the spheric joint as shown in Fig 20 and 21 Start positioning the rear bracket as specified on following pages Rear oscillating bracket installa...

Страница 18: ...he back fixation close the leaf and do as follows 1 Release the operator as in Fig 56 to 61 2 Pull out completely the chromium plated rod afterwards bring it back about 0 40 inches 3 Fix the rod on th...

Страница 19: ...perfectly leveled NOTE If the brackets are installed before the operator place the front bracket inch lower than the rear bracket Fig 26 HT LARGE FT LARGE MINI TANK HT FT Fig 27 Fig 28 2 75 4 in Fig...

Страница 20: ...parallel to the gate Fig 29 Fix the stop with the two included screws Put the provided bush A into the rod At this point hook the rod on the front fixation To adjust the stop in opening act on disc an...

Страница 21: ...mechanical positive stops does not cause the reduction of the shaft stroke 1 Release the unit as in Fig 56 to 61 2 Let the rod come out about 3 4 of its run 3 Put the limit switch stops on the front...

Страница 22: ...e sure that the two discs A and B perfeclty fit in opening phase Up Down BREATHER SCREW Fig 36 Fig 37 Unscrew and take off at the end of the installation IMPORTANT Take off the breather screw lower pa...

Страница 23: ...pressure are similar with the opening pressure set slightly higher than the closing one By pass valves are placed under the key release system By pass valve 1 1 2 2 3 3 4 4 Grey Movement in opening Ye...

Страница 24: ...external release mounting Kit for Half Tank Fig 43 Fig 44 Fig 45 Fig 46 by pass cover ALUMINIUM RELEASE WITH KEYMOUNTING HALF TANK MINI TANK Accessory on request EXTERNALRELEASE MOUNTING HALF TANK MI...

Страница 25: ...ig 47 Fig 48 INSTALLATION ON MASONRY PILLARS MAKING A NICHE FullTank Version FullTank Large Version HalfTank MiniTank Version HalfTank Large Version Fig 49 If you have to make a niche observe the dime...

Страница 26: ...n is adjustable by rotating the screw for the brake regulation Rotating clockwise Increase the effect of the slow down Rotating Anti clockwise Decrease the the effect of the slow down NOTE REMEMBER to...

Страница 27: ...27 OIL LEVEL MEASUREMENT HALF TANK NEW MINI TANK Insertion into the motor in 3 34 2 16 3 34 Fig 53 OIL LEVEL MEASUREMENT FULL TANK Oil level Fig 54...

Страница 28: ...examination to prevent in Fig 55 crushing conveying cutting grappling trapping so as to guarantee a safe installation for people things and animals Re Laws in force in the country where installation h...

Страница 29: ...l it stops see Fig 59 remove it put it under the lid and close the lid again Attention Turning the key over 1 turn 360 could damage the release Turn the key anti clockwise to tighten the lid remove th...

Страница 30: ...nti clockwise Fig 60 61 To relock the operator do as follows Insert the key and turn it clockwise until it stops Fig 60 61 Attention To release cut current supply PLASTIC RELEASE SYSTEM HALF TANK NEW...

Страница 31: ...must contact SEAfor instructions WARRANTY for the original buyer only Hydraulic and oil bath motors 36 months warranty from the date of invoice on manufacturing assembling and workmanship defects Ele...

Страница 32: ...0850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 USA Phone 1 305 594 1151 Fax 1 305 594 7325 Toll Free 800 689 4716 web site www sea usa com e mail sales sea usa com International registered tradem...

Отзывы: