58 Sedan Bridge
(585 Sedan Bridge)
3.9
S
ECTION
3 • U
SING
Y
OUR
B
OAT
MASTER IGNITION
PORT
STBD
12. S
TARTING
THE
G
ENERATOR
Sea Ray
®
strongly urges you to fully comply with the
manual provided by the generator manufacturer. The
generator is warranted separately by the
generator manufacturer, NOT Sea Ray
®
. Follow the
recommended maintenance and warranty schedule
in your Generator Operator’s Manual included in the
Owner’s Manual Packet. Generator abuse or
improper maintenance may adversely affect claims
made under generator manufacturer separate
warranty.
7. Turn battery switches OFF.
A. E
MERGENCY
S
TOP
B
UTTON
Your yacht is equipped with an emergency stop
button for each engine located on the control station
switch panel. The emergency stop switch gives the
boat operator the ability to shut down the engines
in an emergency situation.
In any situation which requires the engines to be
shut down immediately, press and hold emergency
stop switch until engine(s) stops completely.
Release switch.
NOTE: Run bilge blowers for 4 minutes before
restarting engine(s). Follow engine starting
instructions.
(Remote control switches are located on the main
distribution panel or local switches on the
generator.)
1. Check fuel tank levels.
2. Check remote fuel valves
making sure the feed and
return valves are operating on
the same fuel tank.
3. Check oil and coolant levels for
proper readings.
4. Check generator for coolant drain plug installation.
5. Open the generator seacock.
6. Run the bilge blowers for at least four minutes
before starting and any time the generator is
running. If fuel fumes are detected, do not start
the generator until the source of fumes is
determined and corrected and the bilge area is
safely ventilated.
7. Press the ON switch,
then, depress the START
switch and hold. The starter
motor will have up to a 15
second delay for the
preheat mode, engine will
automatically start cranking,
As soon as the engine runs, release the
START switch.
Pre-start generator prior to getting underway as there
is a possibility that it will not pick up water if started
underway. Make sure the MAIN GENERATOR breaker
is OFF and there is no load on the generator before
starting it.
NOTICE
DO NOT run the engine or generator in an enclosed
area, such as a closed boat house, as there is the
possibility of buildup and inhaling of carbon monoxide.
!
WARNING
https://www.boat-manuals.com/