THREE (3) YEAR “FG” AND “FD” SERIES LIMITED WARRANTY

We warranty to the original retail purchaser, all SEA-FIRE extinguishers for a period of three (3)
years after retail purchase against defective material and faulty workmanship. Any system found
to be defective during the warranty period will be repaired if possible, or replaced free of charge if
classified non-refillable (according to product label) upon the prepaid return of the defective
system. Proof of purchase required, otherwise date of manufacturer on extinguisher label will
apply. This warranty gives you specific legal rights which may vary by state or country.

THE FOREGOING WARRANTY IS MADE IN LIEU OF ALL OTHER WARRANTIES WITH
RESPECT TO THE SYSTEM INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. NO PERSON IS AUTHORIZED TO GIVE ANY
OTHER WARRANTY, OR TO ASSUME FOR SEA-FIRE MARINE ANY OTHER LIABILITY IN
CONNECTION WITH THE SALE OR INSTALLATION OF ITS PRODUCTS. REPLACEMENT OF
THE SYSTEM WILL BE THE SOLE REMEDY WITH RESPECT TO ANY LOSS OR DAMAGE TO
PROPERTY. BUYER IS NOT RELYING ON SELLER’S JUDGMENT REGARDING BUYER’S
PARTICULAR REQUIREMENTS AND BUYER HAS HAD AN OPPORTUNITY TO INSPECT THE
PRODUCT TO BUYER’S SATISFACTION.

CONDITIONS

All Sea-Fire products are tested after manufacture and shipped in perfect working order.
Damage noted upon receipt of shipment should be addressed as a shipping claim, the filing of
which is the sole responsibility of the consignee for which the total compensatory award will be
limited to that appropriated by the carrier. Insured freight costs are the responsibility of the
consignee. Missing component parts and damage noted upon installation are typically the
result of mishandling during the installation process and will not qualify for warranty coverage.
Incidents of accidental discharge are not indicative of product failure — heed product warnings
to avoid injury and/or associated costs. No returns will be processed without proper return
authorization.

OUT OF WARRANTY REPLACEMENTS/RECHARGES

SEA-FIRE ‘‘FG’’ Model Series cylinders comply with DOT Specification 39. These cylinders are
not refillable. The discharged cylinder will be replaced with a comparable Sea-Fire extinguisher
upon prepaid return of the discharged system for one-half of the current suggested list price.

SEA-FIRE ‘‘FD’’ Model Series cylinders comply with DOT Specification 4B/360, 4BW/500, and
3AL/1000 which allows discharged cylinder to be refilled and serviced. Reference cylinder label
and making to determine the applicable DOT specification. The discharged extinguisher may be
refilled upon the prepaid return of the discharged system. Contact factory or authorized dealer for
detail.

RETURN TO:

UNITED STATES
SEA-FIRE MARINE Division of Metalcraft Inc.
9331-A Philadelphia Road
Baltimore, Maryland 21237 USA

EUROPE
SEA-FIRE EUROPE LTD
Unit 7. io Centre. Stephenson Road
Fareham, Hampshire
PO15 5RU, United Kingdom
PH: 44 (0) 1329 847225
FX: 44 (0) 1329 847226

12

REMINDER: ALWAYS INSTALL SAFETY PIN IN CYLINDER ACTUATOR LEVEL (FIGURE 6A or
7C) WHEN PERFORMING SERVICE OR MAINTENANCE ON SYSTEM. BE SURE TO
REMOVE SAFETY PIN FROM ACTUATOR LEVER UPON COMPLETION OF SERVICING.

INDICATOR LIGHT OPERATION

All Sea-Fire extinguishers approved for marine applications are packaged with an indicator light
and escutcheon. The indicator light (unless replaced by another Sea-Fire method) must be
installed for system supervision and operator awareness. When properly installed, activation of
electrical power to the system will illuminate the light indicating normal charged condition. System
discharge or loss of pressure will immediately extinguish the indicator light. In the event that the
indicator light is not lit when power is applied, check for the following conditions:

1. Check pressure indicator gauge for proper range
2. Check fuse and indicator light and replace if defective (lamp replacements

available from factory).

3. Check for loose electrical connections.
4. Remove and weigh system cylinder as described in Maintenance Section of the

manual.

INDICATOR LIGHT INSTALLATION

Select a location at the helm on or near the console that is in full view of the helmsman. The
location selected must have access for electrical wiring. Remove the adhesive protective cover
from back of indicator escutcheon and attach. For proper adhesion, surface must be clean and
dry and temperature must be above 50°F (10°C). Use the preformed escutcheon hole as a
template and carefully drill a 5/16-inch (8 mm) hole. Insert indicator light wire through hole and
seat light assembly by pressing clip into position. Indicator light is now ready for wiring (see
Figure 3)
.

CAUTION:  PRIOR TO WIRING INDICATOR LIGHT TURN OFF ELECTRICAL POWER BY
SWITCHING OFF CIRCUIT BREAKER, REMOVING FUSE OR DISCONNECTING POSITIVE
BATTERY TERMINAL. FAILURE TO DISCONNECT ELECTRICAL POWER WHILE MAKING
ELECTRICAL CONNECTION CAN RESULT IN INJURY FROM FIRE OR ELECTRICAL BURNS.

The indicator light is rated for 12 VDC (contact factory for other voltages). Wire in accordance
with the American Boating and Yacht Council standard E-9 “Direct Current Electrical System on
Boats, copies of which may be obtained from ABYC, Edgewater, MD USA 21037, (410) 956-
1050.

9

Содержание FD1000A

Страница 1: ...FIRE EXTINGUISHERS INSTALLATION INSTRUCTIONS OWNER S MANUAL THIS MANUAL IS AN INTEGRAL PART OF THE SYSTEM AND AS SUCH THE EXTINGUISHER MUST BE INSTALLED AND MAINTAINED ACCORDINGLY U S COAST GUARD APPROVED FM APPROVED No 162 029 237 0 READ AND COMPLY WITH THESE INSTRUCTIONS WARNINGS AND LIMITATIONS BEFORE INSTALLING SUITABLE FOR USE FG MODELS 0 F 18 C TO 130 F 54 C FD MODELS 20 F 7 C TO 130 F 54 C ...

Страница 2: ... DISCLAIMER OF EXPRESSED AND IMPLIED WARRANTIES Metalcraft Sea Fire Marine Inc has taken reasonable care in preparing this document how ever since the use of this information and the conditions of use of the product are not within the control of Metalcraft Sea Fire Marine Inc it is the user s obligation to determine the con ditions of safe use of this product The information in this document is of...

Страница 3: ...nd or heart irregularities arrhythmias Misuse of the products by deliberately inhaling high concentrations of this gas could cause death without warning Persons with preexisting cardiac or central nervous sys tem disorders may be more susceptible to effects of an overexposure Section 12 Ecological Information No ecological information is available Section 13 Disposal Considerations Dispose of wast...

Страница 4: ...t the combustion reaction cannot sustain itself CAUTION IN CASE OF EXTINGUISHER DISCHARGE DO NOT RUSH TO OPEN THE PROTECTED COMPARTMENT LET THE EXTINGUISHING AGENT WORK FOR SEVERAL MINUTES HAVE A PORTABLE EXTINGUISHER AVAILABLEAND USE CARE WHEN OPENING THE COMPARTMENT AVOID BREATHING FIRE RELATED FUMES OR VAPOR NOTE It is important to retain the designed vapor concentration within the compartment ...

Страница 5: ... 2 0 AMPS AT 28 VDC For applications requiring larger load capacities see optional equipment section in this manual or contact factory ENGINES AND POWERED VENTILATION BLOWERS DIESEL ENGINES Continued operation of diesel engine s and or powered ventilation units will deplete the extinguishing agent and may cause a fire re flash Diesel engine s must be automatically shutdown upon extinguisher discha...

Страница 6: ...26 150 3 5 4 2 5 4 2 4 6 5 2 9 5 2x17 0 132x476 FD175A FD175M 151 175 4 2 5 0 6 5 2 9 7 6 3 4 5 2x17 0 132x476 FD200A FD200M 176 200 5 0 5 7 7 6 3 4 8 7 3 9 5 2x17 0 132x476 FD225A FD225M 201 225 5 7 6 4 8 7 3 9 9 7 4 4 5 2x17 0 132x476 FD250A FD250M 226 250 6 4 7 1 9 7 4 4 10 8 4 9 6 9x18 0 175x463 FD275A FD275M 251 275 7 1 7 8 10 8 4 9 11 9 5 4 6 9x18 0 175x463 FD300A FD300M 276 300 7 8 8 5 11 9...

Страница 7: ...0 APPROVED FOR VERTICAL OR HORIZONTAL MOUNTING MODEL FD 1050 thru FD 1500 FOR VERTICAL MOUNTING ONLY Cubic Feet CU FT Kilograms KG Cubic Meters CU M Inches IN Pounds LBS Millimeters MM V M E O R U O T N N I T L C I Y A N L G 14 Step 5 Locate bracket in desired position Vertical Sensor Valve Detector Head Up or Horizontal Figure 2 Using the bracket as a template mark and drill holes in bulkhead and...

Страница 8: ...6 or 7 a Before attaching cable to the cylinder check that the cylinder bracket is located correctly and firmly mounted b With the cylinder strapped in its bracket pass the cable jacket ferrule completely through the hole in the cylinder manifold This will allow the necessary cable flexibility needed for inserting the offset end of the flexible shaft into the actuator lever After connecting the sh...

Страница 9: ...l and making to determine the applicable DOT specification The discharged extinguisher may be refilled upon the prepaid return of the discharged system Contact factory or authorized dealer for detail RETURN TO UNITED STATES SEA FIRE MARINE Division of Metalcraft Inc 9331 A Philadelphia Road Baltimore Maryland 21237 USA EUROPE SEA FIRE EUROPE LTD Unit 7 io Centre Stephenson Road Fareham Hampshire P...

Страница 10: ...icate the ability to discharge the agent but not the quantity of extinguishing agent The cylinder less bracket must be weighed on at least a semiannual basis and be replaced immediately if gross weight has decreased by quantity noted on the specification label Never paint or obstruct the cylinder manifold or sensor valve detector as this will adversely affect its operating characteristic FD models...